ACTIVE CURRENT ELECTRODES FOR IN-VIVO ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:20
|
作者
JOSSINET, J
TOURTEL, C
JARRY, R
机构
[1] Inst. Nat. de la Sante et de la Recherche Medicale, Lyon
关键词
D O I
10.1088/0967-3334/15/2A/012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The characterization of tissue by means of electrical impedance tomography requires accurate impedance measurements at relatively high frequencies. The present study describes the design and fabrication of broad-band, active, current electrodes for in vivo measurements. This approach eliminates the lead capacitances of the sourcing electrodes. The value of the resistors used were computed according to a protocol taking into account the constraints of a given application and the values and tolerances of the available components. Additional selection of the components further reduced the variability in circuit performance. The current sources designed according to the method described are usable at frequencies higher than 1 MHz, for differential load impedances up to 2000 OMEGA. The parallel output conductance for each active electrode is 0.85 muS+/-2%. The design method is valid for either adjacent or diametric drive, and can be applied to various applications by modifying the shape of the electrode.
引用
收藏
页码:A83 / A90
页数:8
相关论文
共 50 条
  • [31] COMPARING RECONSTRUCTION ALGORITHMS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    YORKEY, TJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (11) : 843 - 852
  • [32] ANALYTIC SOLUTION OF THE FORWARD PROBLEM FOR INDUCED CURRENT ELECTRICAL-IMPEDANCE TOMOGRAPHY SYSTEMS
    ANDERSON, DK
    TOZER, RC
    FREESTON, IL
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1995, 142 (06) : 425 - 432
  • [33] THE IMPORTANCE OF PHASE MEASUREMENT IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    GRIFFITHS, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (11): : 1435 - 1444
  • [34] A TRANSPUTER IMPLEMENTED ALGORITHM FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ZADEHKOOCHAK, M
    HAMES, TK
    BLOTT, BH
    GEORGE, RF
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03): : 223 - 230
  • [35] FAST, NONLINEAR INVERSION FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    LIONHEART, W
    PIDCOCK, M
    IMAGE AND VISION COMPUTING, 1994, 12 (06) : 367 - 373
  • [36] ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH PIECEWISE POLYNOMIAL CONDUCTIVITIES
    YORKEY, TJ
    JOURNAL OF COMPUTATIONAL PHYSICS, 1990, 91 (02) : 344 - 360
  • [37] CURRENT DISTRIBUTION AND FINITE-ELEMENT MESH SELECTION FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KYTOMAA, HK
    WESELAKE, KL
    COMPUTATIONAL MECHANICS, 1994, 15 (02) : 161 - 172
  • [38] CLINICAL IMPLEMENTATION OF ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH HYPERTHERMIA
    MOSKOWITZ, MJ
    RYAN, TP
    PAULSEN, KD
    MITCHELL, SE
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1995, 11 (02) : 141 - 149
  • [39] CLINICAL-APPLICATIONS OF ELECTRICAL-IMPEDANCE TOMOGRAPHY
    DIJKSTRA, AM
    BROWN, BH
    LEATHARD, AD
    HARRIS, ND
    BARBER, DC
    EDBROOKE, DL
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1993, 17 (03) : 89 - 98
  • [40] DIFFERENTIAL SYNCHRONOUS DEMODULATION FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KOUKOURLIS, CS
    KYRIAKOU, GA
    SAHALOS, JN
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 31 - 34