CLINICAL AND HEMODYNAMIC PERFORMANCE OF THE 19-MM CARPENTIER-EDWARDS PORCINE BIOPROSTHESIS

被引:18
|
作者
BOJAR, RM
RASTEGAR, H
PAYNE, DD
MACK, CA
SCHWARTZ, SL
机构
[1] TUFTS UNIV NEW ENGLAND MED CTR,DEPT CARDIOL,BOSTON,MA 02111
[2] TUFTS UNIV,SCH MED,BOSTON,MA 02111
来源
ANNALS OF THORACIC SURGERY | 1993年 / 56卷 / 05期
关键词
D O I
10.1016/0003-4975(95)90032-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Because of concerns about the hemodynamic performance of 19-mm porcine valves, we retrospectively reviewed the clinical results and echocardiographic studies of 52 consecutive patients who received a 19-mm Carpentier-Edwards porcine bioprosthesis (model 2625) for aortic valve replacement from 1986 through 1991. Nearly 87% of the patients were women, the mean age was 69 years, and the mean body surface area was 1.63 +/- 0.27 m2. Seventy-three percent of the patients had pure aortic stenosis, 96% were in New York Heart Association classes III and IV, and 56% underwent urgent or emergent operation. Overall hospital mortality was 7.7% with a late mortality of 8.3% at a mean follow-up of 25 +/- 18 months. No patient experienced a valve-related complication, and 95% of surviving patients were in New York Heart Association classes I and II. Two-dimensional and Doppler echocardiography performed during the first postoperative week revealed a maximal instantaneous gradient of 44.7 +/- 13.0 mm Hg. In 43 patients for whom additional data were available, the mean gradient was 26.4 +/- 8.2 mm Hg with an effective orifice area of 0.85 +/- 0.18 cm2. This study defines the normal range of postoperative gradients across the 19-mm Carpentier-Edwards porcine valve and demonstrates that patients receiving this valve can achieve significant clinical improvement despite the presence of high transvalvular gradients measured by echocardiography.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 50 条
  • [41] RISK OF THROMBOEMBOLISM WITH THE AORTIC CARPENTIER-EDWARDS BIOPROSTHESIS
    ORSZULAK, TA
    SCHAFF, HV
    MULLANY, CJ
    ANDERSON, BJ
    ILSTRUP, DM
    PUGA, FJ
    DANIELSON, GK
    ANNALS OF THORACIC SURGERY, 1995, 59 (02): : 462 - 468
  • [42] Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis
    Banbury, MK
    Cosgrove, DM
    Thomas, JD
    Blackstone, EH
    Rajeswaran, J
    Okies, JE
    Frater, RM
    ANNALS OF THORACIC SURGERY, 2002, 73 (05): : 1460 - 1465
  • [43] EXPERIENCE WITH THE SELECTIVE USE OF THE CARPENTIER-EDWARDS BIOPROSTHESIS
    LOUAGIE, Y
    MUTEBA, P
    MARCHANDISE, B
    KREMER, R
    SCHOEVAERDTS, JC
    CHALANT, CH
    THORACIC AND CARDIOVASCULAR SURGEON, 1986, 34 (02): : 77 - 81
  • [44] Carpentier-Edwards porcine bioprostheses: Clinical performance assessed by actual analysis
    Jamieson, WRE
    Miyagishima, RT
    Burr, LH
    Lichtenstein, SV
    Fradet, GJ
    Janusz, MT
    JOURNAL OF HEART VALVE DISEASE, 2000, 9 (04): : 530 - 535
  • [45] Aortic Carpentier-Edwards supraannular porcine bioprosthesis:: A 12-year experience
    Logeais, Y
    Langanay, T
    Leguerrier, A
    Rioux, C
    Chaperon, J
    Coutté, MB
    ANNALS OF THORACIC SURGERY, 1999, 68 (02): : 421 - 425
  • [46] CLINICAL-EXPERIENCE WITH THE CARPENTIER-EDWARDS PORCINE XENOGRAFT
    JAMIESON, MPG
    BENNETT, JG
    ROBLES, A
    ROSS, DN
    THORACIC AND CARDIOVASCULAR SURGEON, 1981, 29 (04): : 200 - 205
  • [47] THE CARPENTIER-EDWARDS PERICARDIAL BIOPROSTHESIS - CLINICAL-EXPERIENCE WITH 600 PATIENTS
    PELLETIER, LC
    CARRIER, M
    LECLERC, Y
    DYRDA, I
    ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S297 - S302
  • [48] Carpentier-Edwards PERIMOUNT Magna bioprosthesis: A stented valve with stentless performance?
    Totaro, P
    Degno, N
    Zaidi, A
    Youhana, A
    Argano, V
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (06): : 1668 - 1674
  • [49] CARPENTIER-EDWARDS SUPRAANNULAR PORCINE BIOPROSTHESIS (2ND-GENERATION PROTHESIS) - 12 YEAR PERFORMANCE
    JAMIESON, WRE
    BURR, LH
    MIYAGISHIMA, RT
    LING, H
    FRADET, G
    CIRCULATION, 1995, 92 (08) : 2103 - 2103
  • [50] Long-term evaluation of Carpentier-Edwards porcine bioprosthesis for rheumatic heart disease
    Yu, HY
    Ho, YL
    Chu, SH
    Chen, YS
    Wang, SS
    Lin, FY
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (01): : 80 - 89