Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis

被引:100
|
作者
Banbury, MK
Cosgrove, DM
Thomas, JD
Blackstone, EH
Rajeswaran, J
Okies, JE
Frater, RM
机构
[1] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
[4] Good Samaritan Hosp, Portland, OR 97210 USA
[5] Montefiore Med Ctr Albert Einstein, Bronx, NY 10467 USA
来源
ANNALS OF THORACIC SURGERY | 2002年 / 73卷 / 05期
关键词
D O I
10.1016/S0003-4975(02)03445-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Long-term stability of the hemodynamic performance of commercially available Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount RSR) is unknown. To anticipate the fate of this bioprosthesis, we examined its hemodynamic performance up to 17 years using echocardiographic studies in a Premarket Approval cohort. Methods. Of 267 patients at four institutions in the Premarket Approval cohort, 85 had a total of 168 echocardiographic studies during a 17-year period of yearly follow-up examinations. These were reviewed and quantified in a core echocardiographic facility. Longitudinal data analysis was used to account for repeated, censored data. Results. Mean transvalvular gradient was inversely related to prosthesis size (p = 0.01), and possibly (p = 0.06) increased somewhat during the first 10 years of follow-up, then stabilized. Effective orifice area was larger in larger valve sizes (17 = 0.01), declined somewhat during the first 10 years, and then began to increase again. Ejection fraction declined minimally (p = 0.2). In contrast to the rather stable hemodynamics, aortic regurgitation steadily increased from none to 1 to 2+ (p = 0.005), but rarely (< 10% at 17 years) progressed to 3+ or 4+. Conclusions. The Carpentier-Edwards aortic pericardial bioprosthesis can be anticipated to have an acceptable long-term transvalvular gradient and effective orifice size that will change trivially up to 17 years after implantation. Mild aortic regurgitation will develop progressively. This anticipated hemodynamic resilience supports continued clinical use of the Perimount Carpentier-Edwards bovine pericardial stented bioprosthesis.
引用
收藏
页码:1460 / 1465
页数:6
相关论文
共 50 条
  • [1] HEMODYNAMIC ASSESSMENT OF CARPENTIER-EDWARDS BIOPROSTHESIS IN AORTIC POSITION
    GREHL, T
    LEE, G
    JOYE, JA
    DEMARIA, AN
    HURLEY, E
    KAKU, R
    HARTER, W
    WALLACE, S
    MASON, DT
    CLINICAL RESEARCH, 1978, 26 (02): : A92 - A92
  • [2] HEMODYNAMIC ASSESSMENT OF THE NEW AORTIC CARPENTIER-EDWARDS BIOPROSTHESIS
    LEE, G
    GREHL, TM
    JOYE, JA
    KAKU, RF
    HARTER, W
    DEMARIA, AN
    MASON, DT
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1978, 4 (04): : 373 - 381
  • [3] HEMODYNAMIC EVALUATION OF THE CARPENTIER-EDWARDS BIOPROSTHESIS IN THE AORTIC POSITION
    ROTHKOPF, M
    DAVIDSON, T
    LIPSCOMB, K
    NARAHARA, K
    HILLIS, LD
    WILLERSON, JT
    ESTRERA, A
    PLATT, M
    MILLS, L
    AMERICAN JOURNAL OF CARDIOLOGY, 1979, 44 (02): : 209 - 214
  • [4] HEMODYNAMIC ASSESSMENT OF CARPENTIER-EDWARDS BIOPROSTHESIS IN AORTIC POSITION
    JOYE, JA
    LEE, G
    GREHL, T
    DEMARIA, AN
    HURLEY, E
    KAKU, R
    HARTER, W
    WALLACE, S
    MASON, DT
    CLINICAL RESEARCH, 1978, 26 (03): : A241 - A241
  • [5] Hemodynamic evaluation of 19-mm Carpentier-Edwards pericardial bioprosthesis in aortic position
    Takakura, H
    Sasaki, T
    Hashimoto, K
    Hachiya, T
    Onoguchi, K
    Oshiumi, M
    Takeuchi, S
    ANNALS OF THORACIC SURGERY, 2001, 71 (02): : 609 - 613
  • [6] Failure modes of the Carpentier-Edwards pericardial bioprosthesis in the aortic position
    Roselli, EE
    Smedira, NG
    Blackstone, EH
    JOURNAL OF HEART VALVE DISEASE, 2006, 15 (03): : 421 - 427
  • [7] EVALUATION OF A NEW AORTIC BIOPROSTHESIS - THE CARPENTIER-EDWARDS PERICARDIAL VALVE
    PELLETIER, LC
    CARTIER, R
    BONAN, R
    CREPEAU, J
    DYRDA, I
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1986, 9 (03): : B36 - B36
  • [8] HEMODYNAMICS OF THE HANCOCK PERICARDIAL AND THE CARPENTIER-EDWARDS AORTIC PORCINE BIOPROSTHESIS
    LEROY, G
    DESNOS, M
    BELFANTE, M
    GAIDE, L
    GAY, J
    DELOCHE, A
    GERBAUX, A
    CIRCULATION, 1983, 68 (04) : 343 - 343
  • [9] Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis
    Dellgren, G
    David, TE
    Raanani, E
    Armstrong, S
    Ivanov, J
    Rakowski, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01): : 146 - 154
  • [10] RISK OF THROMBOEMBOLISM WITH THE AORTIC CARPENTIER-EDWARDS BIOPROSTHESIS
    ORSZULAK, TA
    SCHAFF, HV
    MULLANY, CJ
    ANDERSON, BJ
    ILSTRUP, DM
    PUGA, FJ
    DANIELSON, GK
    ANNALS OF THORACIC SURGERY, 1995, 59 (02): : 462 - 468