Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis

被引:100
|
作者
Banbury, MK
Cosgrove, DM
Thomas, JD
Blackstone, EH
Rajeswaran, J
Okies, JE
Frater, RM
机构
[1] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
[4] Good Samaritan Hosp, Portland, OR 97210 USA
[5] Montefiore Med Ctr Albert Einstein, Bronx, NY 10467 USA
来源
ANNALS OF THORACIC SURGERY | 2002年 / 73卷 / 05期
关键词
D O I
10.1016/S0003-4975(02)03445-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Long-term stability of the hemodynamic performance of commercially available Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount RSR) is unknown. To anticipate the fate of this bioprosthesis, we examined its hemodynamic performance up to 17 years using echocardiographic studies in a Premarket Approval cohort. Methods. Of 267 patients at four institutions in the Premarket Approval cohort, 85 had a total of 168 echocardiographic studies during a 17-year period of yearly follow-up examinations. These were reviewed and quantified in a core echocardiographic facility. Longitudinal data analysis was used to account for repeated, censored data. Results. Mean transvalvular gradient was inversely related to prosthesis size (p = 0.01), and possibly (p = 0.06) increased somewhat during the first 10 years of follow-up, then stabilized. Effective orifice area was larger in larger valve sizes (17 = 0.01), declined somewhat during the first 10 years, and then began to increase again. Ejection fraction declined minimally (p = 0.2). In contrast to the rather stable hemodynamics, aortic regurgitation steadily increased from none to 1 to 2+ (p = 0.005), but rarely (< 10% at 17 years) progressed to 3+ or 4+. Conclusions. The Carpentier-Edwards aortic pericardial bioprosthesis can be anticipated to have an acceptable long-term transvalvular gradient and effective orifice size that will change trivially up to 17 years after implantation. Mild aortic regurgitation will develop progressively. This anticipated hemodynamic resilience supports continued clinical use of the Perimount Carpentier-Edwards bovine pericardial stented bioprosthesis.
引用
收藏
页码:1460 / 1465
页数:6
相关论文
共 50 条
  • [21] Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results
    Murakami, T
    Eishi, K
    Nakano, S
    Kobayashi, J
    Sasako, Y
    Isobe, F
    Kosakai, Y
    Kito, Y
    Kawashima, Y
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (01): : 45 - 49
  • [22] Immediate structural valve deterioration of 27-mm Carpentier-Edwards aortic pericardial bioprosthesis
    Fleisher, AG
    Lafaro, RJ
    Moggio, RA
    ANNALS OF THORACIC SURGERY, 2004, 77 (04): : 1443 - 1445
  • [23] Experience with the 19-mm Carpentier-Edwards pericardial bioprosthesis in the elderly
    Carrier, M
    Pellerin, M
    Perrault, LP
    Hébert, Y
    Pagé, P
    Cartier, R
    Dyrda, I
    Pelletier, LC
    ANNALS OF THORACIC SURGERY, 2001, 71 (05): : S249 - S252
  • [24] Influence of age on valve related events with Carpentier-Edwards pericardial bioprosthesis
    Aupart, M
    Babuty, D
    Neville, P
    Fauchier, L
    Sirinelli, A
    Marchand, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (05) : 929 - 934
  • [25] Experience with the 19-mm Carpentier-Edwards pericardial bioprosthesis in the elderly
    Carrier, M
    Pellerin, M
    Perrault, LP
    Hebert, Y
    Cartier, R
    Pelletier, LC
    CIRCULATION, 2000, 102 (18) : 786 - 786
  • [26] The Carpentier-Edwards pericardial aortic valve: Intermediate results
    Frater, RWM
    Salomon, NW
    Rainer, WG
    Cosgrove, DM
    Wickham, E
    ANNALS OF THORACIC SURGERY, 1998, 66 (06): : 2153 - 2154
  • [27] Carpentier-Edwards pericardial valve in the aortic position: 25-years experience
    Jose Dalmau, Maria
    CIRUGIA CARDIOVASCULAR, 2014, 21 (01): : 67 - 68
  • [28] 20 years' durability of Carpentier-Edwards Perimount stented pericardial aortic valve
    Bergoend, E.
    Aupart, M. R.
    Mirza, A.
    Meurisse, Y. A.
    Sirinelli, A. L.
    Neville, P. H.
    Marchand, M. A.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 441 - +
  • [29] A case of Carpentier-Edwards pericardial bioprosthesis in mitral position explanted 22 years after implantation
    Kubota, Suguru
    Wakasa, Satoru
    Ooka, Tomonori
    Tachibana, Tsuyoshi
    Shiiya, Norihiko
    Matsui, Yoshiro
    JOURNAL OF ARTIFICIAL ORGANS, 2010, 13 (01) : 48 - 50
  • [30] Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience
    Forcillo, Jessica
    Pellerin, Michel
    Perrault, Louis P.
    Cartier, Raymond
    Bouchar, Denis
    Demers, Philippe
    Carrier, Michel
    ANNALS OF THORACIC SURGERY, 2013, 96 (02): : 486 - 493