Dosimetric comparison of surface mould HDR brachytherapy with VMAT

被引:11
|
作者
Boman, Eeva L. [1 ,2 ,3 ]
Paterson, Dean B. [1 ]
Pearson, Shelley [1 ]
Naidoo, Nichola [1 ]
Johnson, Carol [1 ]
机构
[1] Wellington Hosp, Blood & Canc Ctr, Wellington, New Zealand
[2] Tampere Univ Hosp, Dept Oncol, POB 2000, FI-33521 Tampere, Finland
[3] Tampere Univ Hosp, Dept Med Phys, Tampere, Finland
来源
JOURNAL OF MEDICAL RADIATION SCIENCES | 2018年 / 65卷 / 04期
关键词
Brachytherapy; Freiburg Flap; Intensity-modulated radiation therapy; scalp; skin; volumetric-modulated arc therapy;
D O I
10.1002/jmrs.301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction The aim of this study was to investigate the dosimetric differences between surface mould high-dose-rate (HDR) brachytherapy and external beam volumetric-modulated arc therapy (VMAT) for two treatment sites. Methods Results Previously treated HDR brachytherapy surface mould scalp (n = 4) and lower leg (n = 3) treatments were retrospectively analysed. The VMAT plans were optimised using an additional 3-mm setup margin on the clinical target volume (CTV) of the previously treated HDR plans. The HDR plans were calculated and normalised using the TG-43 formalism and recalculated with Acuros BV (AC). On average, the mean brain and normal tissue doses were reduced by 44.8% and 27.4% for scalp and lower leg VMAT cases, respectively, when compared to AC calculated HDR plans. For VMAT plans, the average dose to a 1-mm thick skin structure deep to the target volume was not any lower than that in AC HDR plans. On average, the CTV coverage was 13.8% and 9.6% lower for scalp cases with AC dose calculation than with TG-43 and 8.3% and 5.3% lower for lower leg cases if 0- or 1-cm backscatter material was applied above the catheters, respectively. Conclusions VMAT is a feasible treatment option in the case of extensive skin malignancies of the scalp and lower leg. Uncertainties related to delivered dose with HDR brachytherapy when using the TG-43 dose calculation model or possible air gaps between the mould and skin favour the use of VMAT. The potential soft tissue deformation needs to be considered if VMAT is used.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [41] Interfractional Dosimetric Variations of the Target and OARs for HDR GYN Brachytherapy
    Washington, B.
    Randall, M.
    Fabian, D.
    Luo, W.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [42] Dosimetric characterizations of a novel inorganic scintillating detector - HDR brachytherapy
    Debnath, S. B. C.
    Tonneau, D.
    Fauquet, C.
    Tallet, A.
    Goncalves, A.
    Ferre, M.
    Darreon, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S99 - S99
  • [43] VMAT for the treatment of gynecologic malignancies for patients unable to receive HDR brachytherapy
    Merrow, Caitlin
    deBoer, Steven
    Podgorsak, Matthew B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 66 - 73
  • [44] Dosimetric comparison of MRI-based HDR brachytherapy and stereotactic radiotherapy in patients with advanced cervical cancer: A virtual brachytherapy study
    Otahal, Bretislav
    Dolezel, Martin
    Cvek, Jakub
    Simetka, Ondrej
    Klat, Jaroslav
    Knybel, Lukas
    Molenda, Lukas
    Skacelikova, Eva
    Hlavka, Ales
    Feltl, David
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (06) : 399 - 404
  • [45] Surface mould brachytherapy planning in giant cell tumour of the tendon sheath of finger and dosimetric comparison with external beam radiotherapy: a case report
    Gupta, Anil
    Pandey, Rambha
    Krishna, Anant
    Kumar, Rishabh
    Sharma, Seema
    Sarawagi, Rashmi
    Garg, Kanika
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (02) : 289 - 293
  • [46] Dosimetric Comparison Between Split Ring and Tandem & Ovoid HDR Brachytherapy Applicators in Cervical Cancer Treatment
    Ishaq, O.
    Montgomery, J. R.
    Duckworth, T.
    Hsu, H.
    Schiff, P. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S857 - S857
  • [47] Real-world dosimetric comparison between CyberKnife SBRT and HDR brachytherapy for the treatment of prostate cancer
    Chatzikonstantinou, Georgios
    Keller, Christian
    Scherf, Christian
    Bathen, Bastian
    Koehn, Janett
    Tselis, Nikolaos
    BRACHYTHERAPY, 2021, 20 (01) : 44 - 49
  • [48] Dosimetric Comparison Between Split Ring Applicator and Tandem and Ovoids for HDR Brachytherapy Boost in Cervical Cancer
    Hsu, H.
    Duckworth, T.
    Schiff, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S891 - S892
  • [49] Uterine perforation and its dosimetric implications in HDR brachytherapy for carcinoma of the cervix
    Bahadur, Y.
    Hassouna, A.
    Eltaher, M.
    Constantinescu, C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S147 - S148
  • [50] Dosimetric benefits and preclinical performance of steerable needles in HDR prostate brachytherapy
    de Vries, M.
    Christianen, M. E. M. C.
    Luthart, L.
    de Vries, K. C.
    Kolkman-Deurloo, I. K. K.
    van den Dobbelsteen, J. J.
    MEDICAL ENGINEERING & PHYSICS, 2024, 128