Dosimetric comparison of surface mould HDR brachytherapy with VMAT

被引:11
|
作者
Boman, Eeva L. [1 ,2 ,3 ]
Paterson, Dean B. [1 ]
Pearson, Shelley [1 ]
Naidoo, Nichola [1 ]
Johnson, Carol [1 ]
机构
[1] Wellington Hosp, Blood & Canc Ctr, Wellington, New Zealand
[2] Tampere Univ Hosp, Dept Oncol, POB 2000, FI-33521 Tampere, Finland
[3] Tampere Univ Hosp, Dept Med Phys, Tampere, Finland
来源
JOURNAL OF MEDICAL RADIATION SCIENCES | 2018年 / 65卷 / 04期
关键词
Brachytherapy; Freiburg Flap; Intensity-modulated radiation therapy; scalp; skin; volumetric-modulated arc therapy;
D O I
10.1002/jmrs.301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction The aim of this study was to investigate the dosimetric differences between surface mould high-dose-rate (HDR) brachytherapy and external beam volumetric-modulated arc therapy (VMAT) for two treatment sites. Methods Results Previously treated HDR brachytherapy surface mould scalp (n = 4) and lower leg (n = 3) treatments were retrospectively analysed. The VMAT plans were optimised using an additional 3-mm setup margin on the clinical target volume (CTV) of the previously treated HDR plans. The HDR plans were calculated and normalised using the TG-43 formalism and recalculated with Acuros BV (AC). On average, the mean brain and normal tissue doses were reduced by 44.8% and 27.4% for scalp and lower leg VMAT cases, respectively, when compared to AC calculated HDR plans. For VMAT plans, the average dose to a 1-mm thick skin structure deep to the target volume was not any lower than that in AC HDR plans. On average, the CTV coverage was 13.8% and 9.6% lower for scalp cases with AC dose calculation than with TG-43 and 8.3% and 5.3% lower for lower leg cases if 0- or 1-cm backscatter material was applied above the catheters, respectively. Conclusions VMAT is a feasible treatment option in the case of extensive skin malignancies of the scalp and lower leg. Uncertainties related to delivered dose with HDR brachytherapy when using the TG-43 dose calculation model or possible air gaps between the mould and skin favour the use of VMAT. The potential soft tissue deformation needs to be considered if VMAT is used.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [31] Dosimetric Comparison of different Computational Algorithms in CT-assisted interstitial HDR-Brachytherapy
    Hermani, H.
    Teuber, K.
    Willmes, N.
    Klein, C.
    Azmoudeh, A.
    Pinkawa, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S71 - S71
  • [32] Distribution of Interfractional Dosimetric Variation of HRCTV in Cervix HDR Brachytherapy
    Washington, B.
    Randall, M.
    Fabian, D.
    Cheek, D.
    Wang, C.
    Luo, W.
    MEDICAL PHYSICS, 2022, 49 (06) : E814 - E815
  • [33] The dosimetric impact of interstitial needles in HDR brachytherapy for cervical cancer
    Otter, S.
    Coates, A.
    Franklin, A.
    Brennan, C.
    Cunningham, M.
    Stewart, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [34] Studies performed for the characterization of a mailed dosimetric audit of HDR Brachytherapy
    Canamas, L. Oliver
    Vijande-Asenjo, J.
    Candela-Juan, C.
    Gimeno-Olmos, J.
    Pujades-Claumarchirant, M. C.
    Rovira-Escutia, J. J.
    Martinez-Navarro, J. A.
    Zaragoza-Carrillo, A.
    Calatayud-Jordan, J. M.
    Garcia-Cases, F.
    Ballester-Pallares, F.
    Perez-Calatayud, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1964 - S1965
  • [35] UTERINE PERFORATION AND DOSIMETRIC IMPLICATIONS IN HDR BRACHYTHERAPY FOR CARCINOMA OF THE CERVIX
    Bahader, Y.
    Eltaher, M.
    Hassouna, A.
    Constantinescu, C.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2013, 23 (08)
  • [36] Development of Dosimetric Verification System for HDR Brachytherapy: A Feasibility Study
    Kang, S.
    Chung, J.
    Cho, W.
    Kang, S.
    Kim, K.
    Shin, D.
    Suh, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E744 - E745
  • [37] Gynecological applicator instrumented with GaN dosimetric probes for HDR brachytherapy
    Guiral, Pierrick
    Wang, Ruoxi
    Galvan, Jean-Marc
    Lu, Guo-Neng
    Jalade, Patrice
    Ribouton, Julien
    Pittet, Patrick
    RADIATION MEASUREMENTS, 2017, 106 : 563 - 568
  • [38] Evaluating Dosimetric Metrics Uncertainties in HDR Prostate Brachytherapy Using Independent Dosimetric Validation
    Yue, Y.
    Ng, S. K.
    Huang, K. C.
    Campos, D. D.
    Oderinde, O.
    Ishaq, O.
    MEDICAL PHYSICS, 2024, 51 (10) : 7742 - 7742
  • [39] Nomogram as an Efficient Dosimetric Verification Tool in HDR Prostate Brachytherapy
    Liang, J.
    Todor, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3626 - 3626
  • [40] DOSIMETRIC EVALUATION OF RECTAL DOSE IN HDR INTRACAVITARY BRACHYTHERAPY OF CERVIX
    Khan, A. A.
    Vijay, A.
    Rather, S. A.
    Baba, M. H.
    Tali, T. A.
    Sofi, M. A.
    WORLD CANCER RESEARCH JOURNAL, 2023, 10