TIDAL VOLUME MEASUREMENTS IN NEWBORNS USING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY

被引:60
|
作者
ADAMS, JA
ZABALETA, IA
STROH, D
JOHNSON, P
SACKNER, MA
机构
[1] MT SINAI MED CTR,DIV PULM DIS,MIAMI BEACH,FL 33140
[2] FLORIDA INT UNIV,DEPT STAT,MIAMI,FL 33199
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1993年 / 148卷 / 03期
关键词
D O I
10.1164/ajrccm/148.3.585
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Respiratory inductive plethysmography (RIP) is a well-accepted noninvasive technology for monitoring breathing patterns in adults. Prior attempts to calibrate this device in babies have been fraught with technical difficulties, thereby limiting applications in this population. Recently, a new method, qualitative diagnostic calibration (QDC), has been shown to provide accurate calibration of tidal volume in adults. The QDC method is based upon principles of the isovolume maneuver and carried out during natural breathing without specialized respiratory maneuvers or postural changes. We calibrated RIP with QDC in the supine posture and compared tidal volume (VT) measured with RIP to VT by a face mask-pneumotachograph (PNT) in 21 healthy full-term newborns in supine and prone postures. Eleven of the babies were calibrated during active sleep and 10 in quiet sleep. The mean VT in the supine and prone postures were 19 and 25 ml, respectively. In the supine and prone postures, weighted mean difference between RIP (VT) and PNT (VT) and 95% confidence intervals were -0.05 ml (-0.27, 0.18) and -0.32 ml (-0.08, 0.55), respectively. There was no difference in the accuracy of RIP relative to PNT calibrated during active sleep when thoracoabdominal incoordination was present or quiet sleep when it was not in either the supine or the prone postures. Therefore, in full-term infants, RIP calibrated with QDC solely in the supine posture provides clinically acceptable measurements of VT in both supine and prone postures.
引用
收藏
页码:585 / 588
页数:4
相关论文
共 50 条
  • [41] Evaluation of respiratory inductive plethysmography - Accuracy for analysis of respiratory waveforms
    Carry, PY
    Baconnier, P
    Eberhard, A
    Cotte, P
    Benchetrit, G
    CHEST, 1997, 111 (04) : 910 - 915
  • [42] Respiratory inductive plethysmography for noninvasive cardio-respiratory monitoring
    Abdulhay, E.
    Calabrese, P.
    Fontecave-Jallon, J.
    Gumery, P.
    Baconnier, P.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2011, 25 : 46 - 46
  • [43] Respiratory inductive plethysmography to assess respiratory variability and complexity in humans
    Fiamma, Marie-Noelle
    Samara, Ziyad
    Baconnier, Pierre
    Similowski, Thomas
    Straus, Christian
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2007, 156 (02) : 234 - 239
  • [44] ASSESSMENT OF DENSITY DEPENDENT FLOW-VOLUME PARAMETERS IN NONSMOKERS AND SMOKERS - MEASUREMENT WITH SPIROMETRY, BODY PLETHYSMOGRAPHY AND RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    SACKNER, MA
    RAO, ASV
    BIRCH, S
    ATKINS, N
    GIBBS, L
    DAVIS, B
    CHEST, 1982, 82 (02) : 137 - 142
  • [45] TIDAL FLOW-VOLUME LOOPS IN NEWBORNS AND INFANTS WITH RESPIRATORY-DISEASE
    STEELE, A
    STENZLER, A
    STEINBERG, H
    LIPSITZ, P
    PEDIATRIC RESEARCH, 1980, 14 (04) : 652 - 652
  • [46] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN CHRONIC AIRWAYS OBSTRUCTION
    TOBIN, MJ
    JENOURI, G
    WATSON, H
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (04): : 122 - 122
  • [47] Evaluation of Respiratory Inductive Plethysmography in VLBW infants 1709
    Gabriel Musante
    Nelson Claure
    Tilo Gerhardt
    Ruth Everett
    Eduardo Bancalari
    Pediatric Research, 1998, 43 (Suppl 4) : 291 - 291
  • [48] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY WITH CHANGE IN BODY POSTURE
    CHADHA, TS
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 128 (02): : 331 - 331
  • [49] A Wearable Technology Revisited for Cardio-Respiratory Functional Exploration: Stroke Volume Estimation from Respiratory Inductive Plethysmography
    Fontecave-Jallon, Julie
    Gumery, Pierre-Yves
    Calabrese, Pascale
    Briot, Raphael
    Baconnier, Pierre
    INTERNATIONAL JOURNAL OF E-HEALTH AND MEDICAL COMMUNICATIONS, 2013, 4 (01) : 12 - 22
  • [50] COMPARISON OF CALIBRATION METHODS FOR RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN INFANTS
    REVOW, MD
    ENGLAND, SJ
    STOGRYN, HAF
    WILKES, DL
    JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (05) : 1853 - 1861