TIDAL VOLUME MEASUREMENTS IN NEWBORNS USING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY

被引:60
|
作者
ADAMS, JA
ZABALETA, IA
STROH, D
JOHNSON, P
SACKNER, MA
机构
[1] MT SINAI MED CTR,DIV PULM DIS,MIAMI BEACH,FL 33140
[2] FLORIDA INT UNIV,DEPT STAT,MIAMI,FL 33199
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1993年 / 148卷 / 03期
关键词
D O I
10.1164/ajrccm/148.3.585
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Respiratory inductive plethysmography (RIP) is a well-accepted noninvasive technology for monitoring breathing patterns in adults. Prior attempts to calibrate this device in babies have been fraught with technical difficulties, thereby limiting applications in this population. Recently, a new method, qualitative diagnostic calibration (QDC), has been shown to provide accurate calibration of tidal volume in adults. The QDC method is based upon principles of the isovolume maneuver and carried out during natural breathing without specialized respiratory maneuvers or postural changes. We calibrated RIP with QDC in the supine posture and compared tidal volume (VT) measured with RIP to VT by a face mask-pneumotachograph (PNT) in 21 healthy full-term newborns in supine and prone postures. Eleven of the babies were calibrated during active sleep and 10 in quiet sleep. The mean VT in the supine and prone postures were 19 and 25 ml, respectively. In the supine and prone postures, weighted mean difference between RIP (VT) and PNT (VT) and 95% confidence intervals were -0.05 ml (-0.27, 0.18) and -0.32 ml (-0.08, 0.55), respectively. There was no difference in the accuracy of RIP relative to PNT calibrated during active sleep when thoracoabdominal incoordination was present or quiet sleep when it was not in either the supine or the prone postures. Therefore, in full-term infants, RIP calibrated with QDC solely in the supine posture provides clinically acceptable measurements of VT in both supine and prone postures.
引用
收藏
页码:585 / 588
页数:4
相关论文
共 50 条
  • [1] Accuracy and consistency of respiratory inductive plethysmography for overnight tidal volume measurement
    Zhang, Jinnong
    Ruch, Eric W.
    Bloch, Konrad E.
    Journal of Huazhong University of Science and Technology - Medical Science, 2001, 21 (01): : 35 - 37
  • [2] Accuracy and consistency of respiratory inductive plethysmography for overnight tidal volume measurement
    Zhang Jinnong
    Eric W. Ruch
    Konrad E. Bloch
    Current Medical Science, 2001, 21 (1) : 35 - 37
  • [3] RELIABILITY OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY FOR MEASURING TIDAL VOLUME DURING EXERCISE
    CARETTI, DM
    PULLEN, PV
    PREMO, LA
    KUHLMANN, WD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (10): : 918 - 923
  • [4] Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography
    Grossman, Paul
    Spoerle, Monika
    Wilhelm, Frank H.
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 42, 2006, 42 : 193 - 198
  • [6] Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants
    Gagliardi, L
    Rusconi, F
    Aston, H
    Silverman, M
    PEDIATRIC PULMONOLOGY, 1996, 21 (02) : 132 - 137
  • [7] RESPIRATORY MEASUREMENTS DURING EXERCISE USING SELF-CONTAINED RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    STARK, GP
    HODOUS, TK
    HANKINSON, JL
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A378 - A378
  • [8] Respiratory Inductance Plethysmography for tidal volume and minute ventilation measurements in ELBW infants.
    Claure, N
    Gerhardt, T
    Musante, G
    Everett, R
    Bancalari, E
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A671 - A671
  • [9] RIBCAGE AND ABDOMEN MOTION IN NORMAL NEWBORNS DESCRIBED BY RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    WARREN, RH
    ALDERSON, SH
    CLINICAL RESEARCH, 1990, 38 (04): : A928 - A928
  • [10] CALIBRATION OF COMPUTER-ASSISTED (RESPICOMP) RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN NEWBORNS
    WARREN, RH
    ALDERSON, SH
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1985, 131 (04): : 564 - 567