Graphene /ZnO Nanocomposite for Voltammetric Sensing of Vitamin B-6 using Modified Glassy Carbon Electrode

被引:0
|
作者
Salimi, Hadiseh [1 ]
Beitollahi, Hadi [2 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
来源
关键词
Vitamin B-6; Graphene/ZnO nanocomposite; Glassy carbon electrode; Voltammetry;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A convenient, low cost, and sensitive electrochemical method, based on a glassy carbon electrode modified with graphene/ZnO nanocomposite is described for determination of vitamin B-6. The modified electrode exhibited good electrochemical properties toward the oxidation of vitamin B-6. The diffusion coefficient (D=1.89x10(-5) cm(2) s(-1)), and the kinetic parameter such as the electron transfer coefficient, (alpha=0.53) of vitamin B-6 oxidation at the surface of modified electrode was determined using electrochemical approaches. The anodic peak currents of vitamin B-6 were found to be linear in the concentration range of 1.0-16000.0 mu M with the detection limit of 7.2x10(-7) M.
引用
收藏
页码:732 / 740
页数:9
相关论文
共 50 条
  • [21] Stripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode
    Berna Koçak
    Engin Er
    Hüseyin Çelikkan
    Ionics, 2015, 21 : 2337 - 2344
  • [22] Voltammetric Determination of Vitamin B6 Using a Modified Gold Electrode
    Kovanova, M. A.
    Postnov, A. S.
    Vashurin, A. S.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2024, 98 (06) : 1318 - 1321
  • [23] Fenitrothion sensing with reduced graphene oxide decorated fumed silica nanocomposite modified glassy carbon electrode
    Ozcan, Ali
    Topcuogullari, Duygu
    Ozcan, Ayca Atilir
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 179 - 185
  • [24] Electroanalytical Sensing of Asulam Based on Nanocomposite Modified Glassy Carbon Electrode
    Roushani, Mahmoud
    Mohammadi, Farzaneh
    Valipour, Akram
    JOURNAL OF NANOSTRUCTURES, 2020, 10 (01) : 128 - 139
  • [25] Graphene Nanocomposite Modified Glassy Carbon Electrode: As a Sensing Platform for Simultaneous Determination of Methyldopa and Uric Acid
    Movlaee, Kaveh
    Ganjali, Mohammad Reza
    Aghazadeh, Mostafa
    Beitollahi, Hadi
    Hosseini, Morteza
    Shahabi, Shirin
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (01): : 305 - 315
  • [26] Voltammetric determination of trace heavy metals using an electrochemically deposited graphene/bismuth nanocomposite film-modified glassy carbon electrode
    Lee, Sohee
    Park, Seung-Keun
    Choi, Eunjin
    Piao, Yuanzhe
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 : 120 - 127
  • [27] Voltammetric Sensing of Bilirubin Based on Nafion/Electrochemically Reduced Graphene Oxide Composite Modified Glassy Carbon Electrode
    Avan, Asiye Aslihan
    Aydar, Sevda
    Filik, Hayati
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 96 - 103
  • [28] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Dai, Hongxiu
    Wang, Nan
    Wang, Donglei
    Zhang, Xiaomei
    Ma, Houyi
    Lin, Meng
    MICROCHIMICA ACTA, 2016, 183 (11) : 3053 - 3059
  • [29] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Hongxiu Dai
    Nan Wang
    Donglei Wang
    Xiaomei Zhang
    Houyi Ma
    Meng Lin
    Microchimica Acta, 2016, 183 : 3053 - 3059
  • [30] A glassy carbon electrode modified with a copper tungstate and polyaniline nanocomposite for voltammetric determination of quercetin
    Sathish Kumar Ponnaiah
    Prakash Periakaruppan
    Microchimica Acta, 2018, 185