FAVORABLE RESULTS OF TREATMENT OF NARROWED SAPHENOUS-VEIN GRAFTS WITH PALMAZ-SCHATZ STENT IMPLANTATION

被引:23
|
作者
MAIELLO, L
COLOMBO, A
GIANROSSI, R
GOLDENBERG, S
MARTINI, G
FINCI, L
机构
[1] Catheterization Laboratory, Centro Cuore Columbuś, Milan
[2] Centro Cuore Columbus, 20145 Milan
关键词
SEPHENOUS VEIN GRAFTS; INTGRAVASCULAR STENTS; ANGIOPLASTY;
D O I
10.1093/oxfordjournals.eurheartj.a060655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although conventional balloon angioplasty of saphenous vein grafts can be performed with an acceptable acute success and complication rate, restenosis remains a major problem. However, this may be overcome by the implantation of Palmaz-Schatz stents. Palmaz-Schatz stent deployment was performed in our institution in 43 patients who were referred for PTCA of stenosed saphenous vein grafts. Thirty-seven were located at the mid-portion of the graft, seven at the ostium and six at the distal anastomosis. Overall, we used 59 standard length (15 mm) Palmaz-Schatz stents and 22 short (7 mm) stents. In 15 lesions (30%) multiple stents were implanted in tandem to treat diffuse disease. Angiographic success was achieved in 47 of the 50 attempted lesions (94%). Major cardiac complications occurred in three patients. Two patients had procedures complicated by the development of a Q wave myocardial infarction, one of whom underwent urgent CABG. One patient died. There was no episode of subacute thrombosis. The angiographic follow-up of 37 lesions (80% of eligible lesions) at a mean time of 5 ± 2 months (range 1-8) showed a restenosis rate of 11%, and residual post-stent diameter stenosis was associated with a significantly higher restenosis rate. However, no restenosis occurred in lesions receiving multiple stents. Clinical follow-up was performed in all patients, and at a mean of 25 months after the procedure, 64% were free from clinical events, including recurrent angina. Palmaz-Schatz stent implantation is an effective and safe procedure to treat narrowed vein grafts. Particularly encouraging were the results of stent implantation for ostium or mid-portion graft stenoses, as well as the use of multiple stents for the treatment of diffuse disease. © 1994 The European Society of Cardiology.
引用
收藏
页码:1212 / 1216
页数:5
相关论文
共 50 条
  • [41] DEVELOPMENT OF RESTENOSIS BEYOND 6 MONTHS AFTER PALMAZ-SCHATZ STENT IMPLANTATION
    STURM, M
    JOST, S
    NOLTE, CWT
    HAUSLEITER, J
    AMENDE, I
    LICHTLEN, PR
    CIRCULATION, 1995, 92 (08) : 1335 - 1335
  • [42] Immediate results and dilatation effect of the vein-covered Palmaz-Schatz stent assessed by intravascular ultrasound
    Muramatsu, T
    Tukahara, R
    Hou, MM
    Ito, S
    Inoue, T
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 44 (03): : 276 - 282
  • [43] TRANSRADIAL ARTERY PALMAZ-SCHATZ CORONARY STENT IMPLANTATION - RESULTS OF A SINGLE-CENTER FEASIBILITY STUDY
    KIEMENEIJ, F
    LAARMAN, GJ
    AMERICAN HEART JOURNAL, 1995, 130 (01) : 14 - 21
  • [44] Stent Implantation in Saphenous Vein Grafts
    Lozano, Inigo
    Avanzas, Pablo
    Rondan, Juan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (07): : 1042 - 1043
  • [45] Immediate and follow-up results following implantation of the long and short NIR stent: Comparison with the Palmaz-Schatz stent
    Kobayashi, Y
    De Gregorio, J
    Reimers, B
    Di Mario, C
    Finci, L
    Colombo, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 312A - 312A
  • [46] BILIARY STENTS FOR SAPHENOUS-VEIN GRAFTS - REDUCING THE RISK OF STENT IMPLANTATION - COMMENT
    LINNEMEIER, TJ
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 35 (04): : 354 - 354
  • [47] Intravascular ultrasound diagnosis of a coronary true aneurysm after Palmaz-Schatz stent implantation
    Noguchi, T
    Itoh, A
    Miyazaki, S
    Yasuda, S
    Morii, I
    Daikoku, S
    Goto, Y
    Nonogi, H
    CIRCULATION, 1999, 99 (01) : 162 - 163
  • [48] Results of the Nirvana equivalency trial comparing the NIR Primo stent to the Palmaz-Schatz stent
    Baim, DS
    Cutlip, DE
    Lansky, AJ
    Ricci, GB
    Fitzpatrick, M
    CIRCULATION, 1998, 98 (17) : 661 - 662
  • [49] SINGLE-CENTER PALMAZ BILIARY STENT EXPERIENCE IN CORONARY-ARTERIES AND SAPHENOUS-VEIN GRAFTS
    HARDIGAN, KR
    STRUMPF, RK
    EAGAN, JT
    CIRCULATION, 1993, 88 (04) : 308 - 308
  • [50] Impact of the location of recurrent stenosis on revascularization after coronary Palmaz-Schatz stent implantation
    Jost, S
    Nolte, CWT
    Sturm, M
    Hausmann, D
    JOURNAL OF INVASIVE CARDIOLOGY, 1998, 10 (07): : 376 - 379