FAVORABLE RESULTS OF TREATMENT OF NARROWED SAPHENOUS-VEIN GRAFTS WITH PALMAZ-SCHATZ STENT IMPLANTATION

被引:23
|
作者
MAIELLO, L
COLOMBO, A
GIANROSSI, R
GOLDENBERG, S
MARTINI, G
FINCI, L
机构
[1] Catheterization Laboratory, Centro Cuore Columbuś, Milan
[2] Centro Cuore Columbus, 20145 Milan
关键词
SEPHENOUS VEIN GRAFTS; INTGRAVASCULAR STENTS; ANGIOPLASTY;
D O I
10.1093/oxfordjournals.eurheartj.a060655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although conventional balloon angioplasty of saphenous vein grafts can be performed with an acceptable acute success and complication rate, restenosis remains a major problem. However, this may be overcome by the implantation of Palmaz-Schatz stents. Palmaz-Schatz stent deployment was performed in our institution in 43 patients who were referred for PTCA of stenosed saphenous vein grafts. Thirty-seven were located at the mid-portion of the graft, seven at the ostium and six at the distal anastomosis. Overall, we used 59 standard length (15 mm) Palmaz-Schatz stents and 22 short (7 mm) stents. In 15 lesions (30%) multiple stents were implanted in tandem to treat diffuse disease. Angiographic success was achieved in 47 of the 50 attempted lesions (94%). Major cardiac complications occurred in three patients. Two patients had procedures complicated by the development of a Q wave myocardial infarction, one of whom underwent urgent CABG. One patient died. There was no episode of subacute thrombosis. The angiographic follow-up of 37 lesions (80% of eligible lesions) at a mean time of 5 ± 2 months (range 1-8) showed a restenosis rate of 11%, and residual post-stent diameter stenosis was associated with a significantly higher restenosis rate. However, no restenosis occurred in lesions receiving multiple stents. Clinical follow-up was performed in all patients, and at a mean of 25 months after the procedure, 64% were free from clinical events, including recurrent angina. Palmaz-Schatz stent implantation is an effective and safe procedure to treat narrowed vein grafts. Particularly encouraging were the results of stent implantation for ostium or mid-portion graft stenoses, as well as the use of multiple stents for the treatment of diffuse disease. © 1994 The European Society of Cardiology.
引用
收藏
页码:1212 / 1216
页数:5
相关论文
共 50 条
  • [21] Short and long-term outcome of narrowed saphenous vein bypass graft: A comparison of Palmaz-Schatz stent, directional coronary atherectomy, and balloon angioplasty
    Waksman, R
    Weintraub, WS
    Ghazzal, Z
    Scott, NA
    Shen, YN
    King, SB
    Douglas, JS
    AMERICAN HEART JOURNAL, 1997, 134 (02) : 274 - 281
  • [22] Angiographic pattern of in-stent restenosis after Palmaz-Schatz stent implantation
    Sharma, SK
    Rajawat, Y
    Kakarala, V
    Marmur, JD
    Duvvuri, S
    Cocke, TP
    Ambrose, JA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 1120 - 1120
  • [23] Effects of cilostazol on angiographic restenosis after the Palmaz-Schatz stent implantation
    Hara, K
    Ikari, Y
    Nakajima, H
    Kuroda, Y
    Tanabe, K
    Tsuji, T
    Nishimura, G
    Minatoya, Y
    Aoki, J
    Watanabe, T
    CORONARY ARTERY DISEASE: PREVENTION TO INTERVENTION, 2000, : 735 - 737
  • [24] IS THE PALMAZ BILIARY STENT THE PERCUTANEOUS INTERVENTION OF CHOICE FOR DISEASED AORTOCORONARY SAPHENOUS-VEIN GRAFTS
    BERNARDI, MM
    MACISAAC, AI
    ELLIS, SG
    FRANCO, I
    WHITLOW, PL
    CIRCULATION, 1993, 88 (04) : 661 - 661
  • [25] Transluminal extraction atherectomy for restenosis following Palmaz-Schatz stent implantation
    Hara, K
    Ikari, Y
    Tamura, T
    Yamaguchi, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (06): : 801 - +
  • [26] Clinical outcome of diabetic patients after Palmaz-Schatz stent implantation
    Blankenbaker, R
    Ghazzal, Z
    Weintraub, WS
    Shen, Y
    King, SB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 415A - 415A
  • [27] PREDICTORS OF THROMBOTIC OCCLUSION FOLLOWING CORONARY PALMAZ-SCHATZ STENT IMPLANTATION
    DOUCET, S
    FAJADET, J
    CAILLARD, J
    CASSAGNEAU, B
    ROBERT, G
    MARCO, J
    CIRCULATION, 1992, 86 (04) : 113 - 113
  • [28] Single versus multiple Palmaz-Schatz stent implantation: Immediate and follow-up results
    Moussa, I
    DiMario, C
    Moses, J
    Reimers, B
    Blengino, S
    Colombo, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 99228 - 99228
  • [29] REPRODUCIBILITY OF THE INTRAVASCULAR ULTRASOUND ASSESSMENT OF STENT IMPLANTATION IN SAPHENOUS-VEIN GRAFTS
    MINTZ, GS
    GRIFFIN, J
    CHUANG, YC
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    LEON, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (17): : 1267 - 1270
  • [30] PERCUTANEOUS TRANSRADIAL ARTERY APPROACH FOR CORONARY PALMAZ-SCHATZ STENT IMPLANTATION
    KIEMENEIJ, F
    LAARMAN, GJ
    AMERICAN HEART JOURNAL, 1994, 128 (01) : 167 - 174