REDUCTION OF THE SAMPLING TIME IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY

被引:5
|
作者
HALLS, DJ
机构
关键词
SAMPLING TIME; ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY;
D O I
10.1039/ja9940901177
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-cost device is described which allows a commercial autosampler to be started before the furnace programme has ended. The time of initiation can be programmed from the furnace controller. For a standard solution of aluminium, overlap times of up to 15 s could be used satisfactorily before the sensitivity and precision deteriorated. Using a more conservative overlap time of 10 s, the device was applied to the routine determination of lead in blood after de-proteinization with nitric acid. For 100 samples split into 5 batches, comparison of results with and without the device showed no apparent difference. With the device, therefore, reduction in cycle time of 10-15 s may be made without detriment to performance.
引用
收藏
页码:1177 / 1178
页数:2
相关论文
共 50 条
  • [21] DETERMINATION OF VANADIUM IN URINE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    BUCHET, JP
    KNEPPER, E
    LAUWERYS, R
    ANALYTICA CHIMICA ACTA, 1982, 136 (APR) : 243 - 248
  • [22] IMPROVEMENT OF THE SMETS METHOD IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    YAN, XP
    LIN, TZ
    LIU, ZJ
    TALANTA, 1990, 37 (02) : 167 - 171
  • [23] DETERMINATION OF SELENIUM IN WATER BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    OHTA, K
    SUZUKI, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (03): : 177 - 180
  • [24] Reducing the detection threshold in electrothermal atomic-absorption spectrometry
    Laptev, SA
    Sadagov, YM
    MEASUREMENT TECHNIQUES, 2001, 44 (08) : 821 - 825
  • [25] Preatomization behavior of palladium in electrothermal atomic-absorption spectrometry
    Slaveykova, VI
    Stoimenov, PK
    Manev, SG
    Lazarov, DL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) : 1259 - 1267
  • [26] DEVELOPMENTS IN PROBE DESIGN FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    OTTAWAY, JM
    CARROLL, J
    COOK, S
    CORR, SP
    LITTLEJOHN, D
    MARSHALL, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (07): : 742 - 747
  • [27] DETERMINATION OF CHROMIUM BY ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY
    MOHAMMED, DA
    ANALYST, 1987, 112 (02) : 209 - 211
  • [28] SLURRY ATOMIZATION OF FOODSTUFFS IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    STEPHEN, SC
    OTTAWAY, JM
    LITTLEJOHN, D
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 328 (4-5): : 346 - 353
  • [29] THERMAL STABILIZATION OF ANTIMONY IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    DAHL, K
    THOMASSEN, Y
    MARTINSEN, I
    RADZIUK, B
    SALBU, B
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) : 1 - 5
  • [30] PERMANENT IRIDIUM MODIFIER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    RADEMEYER, CJ
    RADZIUK, B
    ROMANOVA, N
    SKAUGSET, NP
    SKOGSTAD, A
    THOMASSEN, Y
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) : 739 - 745