EXERCISE MYOCARDIAL PERFUSION SCINTIGRAPHY WITH TECHNETIUM-99M METHOXY ISOBUTYLISONITRILE - A COMPARATIVE-STUDY WITH TL-201

被引:28
|
作者
NAJM, YC
MAISEY, MN
CLARKE, SM
FOGELMAN, I
CURRY, PVL
SOWTON, E
机构
[1] GUYS & ST THOMAS HOSP,UNITED MED & DENT SCH,DIV RADIOL SCI,LONDON SE1 9RT,ENGLAND
[2] GUYS & ST THOMAS HOSP,DEPT CARDIOL,LONDON SE1 9RT,ENGLAND
[3] GUYS & ST THOMAS HOSP,DEPT NUCL MED,LONDON SE1 9RT,ENGLAND
关键词
Isobutylisonitrile; Perfusion scintigraphy; Technetium-99m; Thallium-201;
D O I
10.1016/0167-5273(90)90252-Z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The evaluation of technetium-99m methoxy isobutylisonitrile for the diagnosis of coronary artery disease requires comparative validation against thallium-201, the established perfusion imaging agent. We have compared myocardial and lung uptake of both radiotracers following maximal exercise in 52 patients: 40 with angiographically proven coronary disease. Qualitative and quantitative image analysis showed the diagnostic sensitivity of technetium-99m methoxy isobutylisonitrile to compare favourably with that of thallium-201 as reflected by the mean number of ischaemic segments identified: 5.6 ± 2.5 vs 4.8 ± 2.1 by qualitative analysis, and 5.7 ± 3.2 vs 5.0 ± 2.6 segments by quantitative analysis. More reversibly ischaemic segments per patient were identified with technetium-99m methoxy isobutylisonitrile than with thallium-201: 3.6 ± 2.3 vs 1.8 ± 1.9. There was a higher exercise myocardial to background count ratio with technetium-99m methoxy isobutylisonitrile: 3.16:1 vs 2.58:1, and the mean exercise lung uptake normalised to left ventricular uptake ('lung index'), was lower for technetium-99m methoxy isobutylisonitrile than for thallium-201 (36 ± 8% vs 40 ± 10%). Five of the six patients with abnormal elevation of the thallium-201 exercise lung index also had elevation of the technetium-99m methoxy isobutylisonitrile exercise lung index, and all had extensive coronary artery disease. These results indicate that technetium-99m methoxy isobutylisonitrile is at least as effective as thallium-201 for detecting exercise induced myocardial ischaemia. However, technetium-99m methoxy isobutylisonitrile provides a better image quality and may be a more sensitive marker of defect reversibility. For both radiotracers lung uptake is increased with extensive coronary artery disease and measurement of this variable provides prognostic information. © 1990.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 50 条
  • [31] IMPROVEMENT OF MYOCARDIAL PERFUSION AFTER THROMBOLYSIS ASSESSED BY TL-201 EXERCISE SCINTIGRAPHY
    VANDERWALL, EE
    RES, JCJ
    VANDENPOL, R
    VERMEER, F
    VANDERLAARSE, A
    BRAAT, S
    FIORETTI, P
    KRAUSS, XH
    VERHEUGT, FWA
    SIMOONS, ML
    EUROPEAN HEART JOURNAL, 1988, 9 (08) : 828 - 835
  • [32] MYOCARDIAL PERFUSION IMAGING WITH TECHNETIUM-99M-TC NOET - COMPARISON WITH TL-201 AND CORONARY ANGIOGRAPHY
    FAGRET, D
    MARIE, PY
    BRUNOTTE, F
    GIGANTI, M
    LEGULUDEC, D
    BERTRAND, A
    WOLF, JE
    PIFFANELLI, A
    CHOSSAT, F
    BEKHECHI, D
    PASQUALINI, R
    MACHECOURT, J
    COMET, M
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (06) : 936 - 943
  • [33] DUAL MYOCARDIAL IMAGING WITH TECHNETIUM-99M PYROPHOSPHATE AND TL-201 FOR DETECTING, LOCALIZING AND SIZING ACUTE MYOCARDIAL-INFARCTION
    HENNING, H
    SCHELBERT, HR
    RIGHETTI, A
    ASHBURN, WL
    OROURKE, RA
    AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (02): : 147 - 155
  • [34] EXERCISE TL-201 SCINTIGRAPHY IN THE LOCALIZATION OF MYOCARDIAL ISCHEMIA
    KORKEILA, P
    HIETANEN, E
    PARVIAINEN, S
    VIRKKI, R
    HARTIALA, J
    CLINICAL PHYSIOLOGY, 1989, 9 (06): : 555 - 565
  • [35] EXERCISE TL-201 MYOCARDIAL SCINTIGRAPHY - ADVANTAGES AND LIMITATIONS
    ISKANDRIAN, AS
    MINTZ, GS
    CROLL, MN
    WALLNER, R
    BEMIS, CE
    KIMBIRIS, D
    SEGAL, BL
    CARDIOLOGY, 1980, 65 (03) : 136 - 152
  • [36] Technetium-99m tetrofosmin imaging with nitrate infusion to detect severely ischaemic but viable myocardium: A comparative study with TL-201
    Kula, M
    Tutus, A
    Unal, S
    Oguzhan, A
    Ergin, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1060 - 1060
  • [37] PRECORDIAL S-T SEGMENT DEPRESSION IN INFERIOR MYOCARDIAL-INFARCTION - EVALUATION BY QUANTITATIVE TL-201 SCINTIGRAPHY AND TECHNETIUM-99M VENTRICULOGRAPHY
    ONG, L
    VALDELLON, B
    COROMILAS, J
    BRODY, R
    REISER, P
    MORRISON, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (05): : 734 - 739
  • [38] PER-RECTAL PORTAL SCINTIGRAPHY - COMPARISON BETWEEN TECHNETIUM-99M, TL-201, AND IODINE-123 HIPDM
    URBAIN, D
    JEGHERS, O
    HAM, HR
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (12) : 2020 - 2021
  • [39] ACUTE MYOCARDIAL-INFARCTION IMAGED WITH BOTH TECHNETIUM-99M STANNOUS PYROPHOSPHATE AND TL-201 - CLINICAL EVALUATION
    PARKEY, RW
    BONTE, FJ
    STOKELY, EM
    LEWIS, SE
    BUJA, LM
    WILLERSON, JT
    CIRCULATION, 1975, 52 (04) : 71 - 71
  • [40] SCINTIGRAPHIC DETECTION OF PARATHYROID ABNORMALITIES UTILIZING TECHNETIUM-99M TL-201 SUBTRACTION TECHNIQUE
    WEISS, DW
    KLEINSCHMIDT, JC
    HARRIS, WT
    PRATHER, JL
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (02) : AB3 - AB3