EXERCISE MYOCARDIAL PERFUSION SCINTIGRAPHY WITH TECHNETIUM-99M METHOXY ISOBUTYLISONITRILE - A COMPARATIVE-STUDY WITH TL-201

被引:28
|
作者
NAJM, YC
MAISEY, MN
CLARKE, SM
FOGELMAN, I
CURRY, PVL
SOWTON, E
机构
[1] GUYS & ST THOMAS HOSP,UNITED MED & DENT SCH,DIV RADIOL SCI,LONDON SE1 9RT,ENGLAND
[2] GUYS & ST THOMAS HOSP,DEPT CARDIOL,LONDON SE1 9RT,ENGLAND
[3] GUYS & ST THOMAS HOSP,DEPT NUCL MED,LONDON SE1 9RT,ENGLAND
关键词
Isobutylisonitrile; Perfusion scintigraphy; Technetium-99m; Thallium-201;
D O I
10.1016/0167-5273(90)90252-Z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The evaluation of technetium-99m methoxy isobutylisonitrile for the diagnosis of coronary artery disease requires comparative validation against thallium-201, the established perfusion imaging agent. We have compared myocardial and lung uptake of both radiotracers following maximal exercise in 52 patients: 40 with angiographically proven coronary disease. Qualitative and quantitative image analysis showed the diagnostic sensitivity of technetium-99m methoxy isobutylisonitrile to compare favourably with that of thallium-201 as reflected by the mean number of ischaemic segments identified: 5.6 ± 2.5 vs 4.8 ± 2.1 by qualitative analysis, and 5.7 ± 3.2 vs 5.0 ± 2.6 segments by quantitative analysis. More reversibly ischaemic segments per patient were identified with technetium-99m methoxy isobutylisonitrile than with thallium-201: 3.6 ± 2.3 vs 1.8 ± 1.9. There was a higher exercise myocardial to background count ratio with technetium-99m methoxy isobutylisonitrile: 3.16:1 vs 2.58:1, and the mean exercise lung uptake normalised to left ventricular uptake ('lung index'), was lower for technetium-99m methoxy isobutylisonitrile than for thallium-201 (36 ± 8% vs 40 ± 10%). Five of the six patients with abnormal elevation of the thallium-201 exercise lung index also had elevation of the technetium-99m methoxy isobutylisonitrile exercise lung index, and all had extensive coronary artery disease. These results indicate that technetium-99m methoxy isobutylisonitrile is at least as effective as thallium-201 for detecting exercise induced myocardial ischaemia. However, technetium-99m methoxy isobutylisonitrile provides a better image quality and may be a more sensitive marker of defect reversibility. For both radiotracers lung uptake is increased with extensive coronary artery disease and measurement of this variable provides prognostic information. © 1990.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 50 条
  • [21] SUCCESSFUL LOCALIZATION OF PARATHYROID ADENOMATA BY TL-201 AND TECHNETIUM-99M SUBTRACTION SCINTIGRAPHY - DESCRIPTION OF AN IMPROVED TECHNIQUE
    FOGELMAN, I
    MCKILLOP, JH
    BESSENT, RG
    BOYLE, IT
    GRAY, HW
    GUNN, I
    HUTCHISON, JSF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (12): : 545 - 547
  • [22] TECHNIQUE AND 1ST RESULTS OF THE SUBTRACTION SCINTIGRAPHY OF THE PARATHYROID USING TL-201 AND TECHNETIUM-99M
    KRAUS, W
    WAGNER, PK
    HAHN, K
    ROTHMUND, M
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1984, 15 (04): : 216 - &
  • [23] USEFULNESS OF TL-201 AND TECHNETIUM-99M HSA SCINTIGRAPHY FOR DIAGNOSIS AND EVALUATION OF LEFT-VENTRICULAR FUNCTION IN MYOCARDIAL-INFARCTION
    IMAI, S
    OHSHIMA, S
    IIZUKA, T
    YAMAMOTO, H
    KAWAI, Y
    KANESAWA, N
    KANDA, H
    SUZUKI, T
    ISHIZAWA, Y
    MURATA, K
    INOUE, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1981, 45 (08): : 987 - 988
  • [24] MYOCARDIAL PERFUSION IMAGING WITH A NEW RADIOTRACER, TECHNETIUM-99M-HEXAMIBI (METHOXY ISOBUTYL ISONITRILE) - COMPARISON WITH TL-201 IMAGING
    TAILLEFER, R
    DUPRAS, G
    SPORN, V
    RIGO, P
    LEVEILLE, J
    BOUCHER, P
    PEREZBALINO, N
    CAMIN, LL
    MCKUSICK, KA
    CLINICAL NUCLEAR MEDICINE, 1989, 14 (02) : 89 - 96
  • [25] COMPARATIVE-ASSESSMENT OF INFARCT SIZE WITH QUANTITATIVE TL-201 AND TECHNETIUM-99M PYROPHOSPHATE DUAL MYOCARDIAL IMAGING IN DOG
    ZARET, BL
    LANGE, RC
    LEE, JC
    AMERICAN JOURNAL OF CARDIOLOGY, 1977, 39 (02): : 309 - 309
  • [26] COMPARISON OF PERSONNEL RADIATION-DOSIMETRY FROM MYOCARDIAL PERFUSION SCINTIGRAPHY - TECHNETIUM-99M-SESTAMIBI VERSUS TL-201
    CULVER, CM
    DWORKIN, HJ
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (07) : 1210 - 1213
  • [27] MYOCARDIAL SCINTIGRAPHY WITH TL-201/M-201
    LICHTE, H
    FORTSCHRITTE DER MEDIZIN, 1977, 95 (14) : 899 - 903
  • [28] Technetium-99m tetraofosmin - A proven perfusion marker for myocardial scintigraphy
    Steffe, AM
    Stirner, H
    NUKLEARMEDIZIN, 1996, 35 (03) : A1 - A4
  • [29] COMPARATIVE-STUDY OF MYOCYTES IN CULTURES OF TL-201 AND A NEW TECHNETIUM MYOCARDIAL IMAGING AGENT
    MOINS, N
    MAUBLANT, J
    MORETTI, JL
    GACHON, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1987, 80 (05): : 745 - 745
  • [30] DETECTION OF LESIONS IN TL-201 MYOCARDIAL PERFUSION SCINTIGRAPHY
    VOS, PH
    VOSSEPOEL, AM
    HERMANS, J
    PAUWELS, EKJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1982, 7 (04): : 174 - 180