The sensitivity of gamma index analysis to detect multileaf collimator (MLC) positioning errors using Varian TrueBeam EPID and ArcCHECK for patient-specific prostate volumetric-modulated arc therapy (VMAT) quality assurance

被引:9
|
作者
Maraghechi, Borna [1 ]
Davis, Jack [1 ,2 ]
Mitchell, Nicholas [1 ,2 ]
Shah, Meeral [1 ,2 ]
Fleck, Andre [1 ,3 ]
Darko, Johnson [1 ,2 ,3 ]
Osei, Ernest [1 ,2 ,3 ,4 ]
机构
[1] Grand River Reg Canc Ctr, Dept Med Phys, 835 King St W, Kitchener, ON N2G 1G3, Canada
[2] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[3] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[4] Univ Waterloo, Dept Syst Design, Waterloo, ON, Canada
关键词
ArcCHECK; EPID dosimetry; gamma index; prostate cancer; VMAT quality assurance;
D O I
10.1017/S1460396917000425
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Due to the increased degree of modulation and complexity of volumetric-modulated arc therapy (VMAT) plans, it is necessary to have a pre-treatment patient-specific quality assurance (QA) programme. The gamma index is commonly used to quantitatively compare two dose distributions. In this study we investigated the sensitivity of single-and multi-gamma criteria techniques to detect multileaf collimator (MLC) positioning errors using the Varian TrueBeam Electronic Portal Imaging Device (TM) (EPID) dosimetry and the ArcCHECK (TM) device. Materials and methods: All active MLC positions of seven intact prostate patients VMAT plans were randomly changed with a mean value of 0.25, 0.5, 1 and 2 mm and a standard deviation of 0.1mm on 25, 50, 75 and 100% of the control points. The change in gamma passing rates of six gamma criteria of 3%/3mm, 3%/2mm, 3%/1mm, 2%/2 mm, 2%/1mm and 1%/1mm were analysed individually (single-gamma criterion) and as a group (multi-gamma criteria) as a function of the simulated errors. We used the improved and global gamma calculation algorithms with a low dose threshold of 10% in the EPID and ArcCHECK software, respectively. The changes in the planning target volume dose distributions and the organs at risk due to the MLC positioning errors were also studied. Results: When 25, 50, 75 and 100% of the control points were modified by the introduction of the simulated errors, the smallest detectable errors with the EPID were 2, 1, 0.5 and 0.5 mm, respectively, using the multi-gamma criteria technique. Similarly for the single-gamma criteria technique errors as small as 2, 1, 1 and 1 mm applied to 25, 50, 75 and 100% of the control points, respectively, were detectable using a 2%/2 mm criterion. However, the smallest detectable errors with the ArcCHECK when using the multi-gamma criteria technique were 2, 2 and 1mm when MLC errors were applied on 50, 75 and 100% of the control points. When only 25% of the control points were affected the ArcCHECK were unable to detect any of the errors applied. No noticeable difference was observed in the sensitivity using the single-or the multi-gamma criteria techniques with the ArcCHECK. Conclusion: The Varian TrueBeam EPID dosimetry shows a higher sensitivity in detecting MLC positioning errors compared with the ArcCHECK regardless of using the single- or the multi-gamma criteria techniques. Higher sensitivity was observed using the multi-gamma criteria technique compared with the single-criterion technique when using the EPID.
引用
收藏
页码:66 / 77
页数:12
相关论文
共 40 条
  • [31] Quality assurance-based optimization (QAO): Towards improving patient-specific quality assurance in volumetric modulated arc therapy plans using machine learning
    Wall, Phillip D. H.
    Fontenot, Jonas D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 136 - 143
  • [32] Systematic method for a deep learning-based prediction model for gamma evaluation in patient-specific quality assurance of volumetric modulated arc therapy
    Tomori, Seiji
    Kadoya, Noriyuki
    Kajikawa, Tomohiro
    Kimura, Yuto
    Narazaki, Kakutarou
    Ochi, Takahiro
    Jingu, Keiichi
    MEDICAL PHYSICS, 2021, 48 (03) : 1003 - 1018
  • [33] Prediction of patient-specific quality assurance for volumetric modulated arc therapy using radiomics-based machine learning with dose distribution
    Ishizaka, Natsuki
    Kinoshita, Tomotaka
    Sakai, Madoka
    Tanabe, Shunpei
    Nakano, Hisashi
    Tanabe, Satoshi
    Nakamura, Sae
    Mayumi, Kazuki
    Akamatsu, Shinya
    Nishikata, Takayuki
    Takizawa, Takeshi
    Yamada, Takumi
    Sakai, Hironori
    Kaidu, Motoki
    Sasamoto, Ryuta
    Ishikawa, Hiroyuki
    Utsunomiya, Satoru
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):
  • [34] Error detection using a convolutional neural network with dose difference maps in patient-specific quality assurance for volumetric modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Tomori, Seiji
    Oku, Yohei
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 57 - 64
  • [35] Correlation analysis between 2D and 3D patient-specific quality assurance for volumetric modulated arc therapy
    Sharma, S.
    Sharma, D.
    Subramani, V.
    Gopishankar, N.
    Bhaskar, S.
    Pathy, S.
    Kumar, P.
    Thulkar, S.
    Chander, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (04): : 685 - 691
  • [36] New possibilities for volumetric-modulated arc therapy using the AgilityTM 160-leaf multileaf collimator [Neue Bestrahlungsmöglichkeiten bei der volumenmodulierten Arc-Therapie (VMAT) mit dem AgilityTM-160-Lamellen-MLC]
    Blümer N.
    Scherf C.
    Köhn J.
    Kara E.
    Loutfi-Krauß B.
    Imhoff D.
    Rödel C.
    Ramm U.
    Licher J.
    Strahlentherapie und Onkologie, 2014, 190 (11) : 1066 - 1074
  • [37] Improvement Using Planomics Features on Prediction and Classification of Patient-Specific Quality Assurance Using Head and Neck Volumetric Modulated Arc Therapy Plan
    Li, Bing
    Chen, Junying
    Guo, Wei
    Mao, Ronghu
    Zheng, Xiaoli
    Cheng, Xiuyan
    Cui, Tiantian
    Lou, Zhaoyang
    Wang, Ting
    Li, Dingjie
    Tao, Hongyan
    Lei, Hongchang
    Ge, Hong
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [38] Statistical process control and process capability analysis for non-normal volumetric modulated arc therapy patient-specific quality assurance processes
    Xiao, Qing
    Bai, Sen
    Li, Guangjun
    Yang, Kaixuan
    Bai, Long
    Li, Zhibin
    Chen, Li
    Xian, Lixun
    Hu, Zhenyao
    Zhong, Renming
    MEDICAL PHYSICS, 2020, 47 (10) : 4694 - 4702
  • [39] Patient-specific quality control for intensity-modulated radiation therapy and volumetric-modulated arc therapy using electronic portal imaging device and two-dimensional ion chamber array
    Kausar, Abu
    Mani, Karthick R.
    Azhari, Hasin A.
    Zakaria, Golam A.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 26 - 31
  • [40] Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs
    Fiandra, Christian
    Fusella, Marco
    Giglioli, Francesca Romana
    Filippi, Andrea Riccardo
    Mantovani, Cristina
    Ricardi, Umberto
    Ragona, Riccardo
    MEDICAL PHYSICS, 2013, 40 (08)