The sensitivity of gamma index analysis to detect multileaf collimator (MLC) positioning errors using Varian TrueBeam EPID and ArcCHECK for patient-specific prostate volumetric-modulated arc therapy (VMAT) quality assurance

被引:9
|
作者
Maraghechi, Borna [1 ]
Davis, Jack [1 ,2 ]
Mitchell, Nicholas [1 ,2 ]
Shah, Meeral [1 ,2 ]
Fleck, Andre [1 ,3 ]
Darko, Johnson [1 ,2 ,3 ]
Osei, Ernest [1 ,2 ,3 ,4 ]
机构
[1] Grand River Reg Canc Ctr, Dept Med Phys, 835 King St W, Kitchener, ON N2G 1G3, Canada
[2] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[3] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[4] Univ Waterloo, Dept Syst Design, Waterloo, ON, Canada
关键词
ArcCHECK; EPID dosimetry; gamma index; prostate cancer; VMAT quality assurance;
D O I
10.1017/S1460396917000425
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Due to the increased degree of modulation and complexity of volumetric-modulated arc therapy (VMAT) plans, it is necessary to have a pre-treatment patient-specific quality assurance (QA) programme. The gamma index is commonly used to quantitatively compare two dose distributions. In this study we investigated the sensitivity of single-and multi-gamma criteria techniques to detect multileaf collimator (MLC) positioning errors using the Varian TrueBeam Electronic Portal Imaging Device (TM) (EPID) dosimetry and the ArcCHECK (TM) device. Materials and methods: All active MLC positions of seven intact prostate patients VMAT plans were randomly changed with a mean value of 0.25, 0.5, 1 and 2 mm and a standard deviation of 0.1mm on 25, 50, 75 and 100% of the control points. The change in gamma passing rates of six gamma criteria of 3%/3mm, 3%/2mm, 3%/1mm, 2%/2 mm, 2%/1mm and 1%/1mm were analysed individually (single-gamma criterion) and as a group (multi-gamma criteria) as a function of the simulated errors. We used the improved and global gamma calculation algorithms with a low dose threshold of 10% in the EPID and ArcCHECK software, respectively. The changes in the planning target volume dose distributions and the organs at risk due to the MLC positioning errors were also studied. Results: When 25, 50, 75 and 100% of the control points were modified by the introduction of the simulated errors, the smallest detectable errors with the EPID were 2, 1, 0.5 and 0.5 mm, respectively, using the multi-gamma criteria technique. Similarly for the single-gamma criteria technique errors as small as 2, 1, 1 and 1 mm applied to 25, 50, 75 and 100% of the control points, respectively, were detectable using a 2%/2 mm criterion. However, the smallest detectable errors with the ArcCHECK when using the multi-gamma criteria technique were 2, 2 and 1mm when MLC errors were applied on 50, 75 and 100% of the control points. When only 25% of the control points were affected the ArcCHECK were unable to detect any of the errors applied. No noticeable difference was observed in the sensitivity using the single-or the multi-gamma criteria techniques with the ArcCHECK. Conclusion: The Varian TrueBeam EPID dosimetry shows a higher sensitivity in detecting MLC positioning errors compared with the ArcCHECK regardless of using the single- or the multi-gamma criteria techniques. Higher sensitivity was observed using the multi-gamma criteria technique compared with the single-criterion technique when using the EPID.
引用
收藏
页码:66 / 77
页数:12
相关论文
共 40 条
  • [21] Electronic Portal Imaging Device in Pre-Treatment Patient-Specific Quality Assurance of volumetric-modulated arc therapy delivery
    Lau, M. L.
    Abdullah, R.
    Jayamani, J.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [22] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [23] Development and Quality Assurance of Multileaf Collimator (MLC) Auto-Feathering Junctions for Multi-Isocenter Supine Volumetric Modulated Arc Therapy (VMAT) Craniospinal Axis Irradiation on Halcyon
    Misa, Joshua
    Mccarthy, Shane
    St Clair, William
    Pokhrel, Damodar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [24] A study on the correlation between plan complexity and gamma index analysis in patient specific quality assurance of volumetric modulated arc therapy
    Rajasekaran, Dhanabalan
    Jeevanandam, Prakash
    Sukumar, Prabakar
    Ranganathan, Arulpandiyan
    Johnjothi, Samdevakumar
    Nagarajan, Vivekanandan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (01) : 57 - 65
  • [25] Error detection model developed using a multi-task convolutional neural network in patient-specific quality assurance for volumetric-modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Oku, Yohei
    Kajikawa, Tomohiro
    Tomori, Seiji
    Jingu, Keiichi
    MEDICAL PHYSICS, 2021, 48 (09) : 4769 - 4783
  • [26] From 2D to 3D gamma passing rate tolerance and action limits for patient-specific quality assurance in volumetric-modulated arc therapy
    Zarros, Christos
    Patatoukas, George
    Kollaros, Nikos
    Chalkia, Marina
    Kougioumtzopoulou, Andromachi
    Kouloulias, Vasilios
    Platoni, Kalliopi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [27] Dosimetric Validation for Patient-specific Quality Assurance using the Delta44 Phantom with Volumetric Modulated Arc Therapy
    Arino Gil, A.
    Calvo, O.
    Gutierrez, A.
    Papanikolau, N.
    Hdez-Armas, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S717 - S717
  • [28] Statistical analysis of correlation of gamma passing results for two quality assurance phantoms used for patient-specific quality assurance in volumetric modulated arc radiotherapy
    Kunii, Yuki
    Tanabe, Yoshinori
    Nakamoto, Akira
    Nishioka, Kunio
    MEDICAL DOSIMETRY, 2022, 47 (04) : 329 - 333
  • [29] Treatment plan complexity quantification for predicting gamma passing rates in patient-specific quality assurance for stereotactic volumetric modulated arc therapy
    Xue, Xudong
    Luan, Shunyao
    Ding, Yi
    Li, Xiangbin
    Li, Dan
    Wang, Jingya
    Ma, Chi
    Jiang, Man
    Wei, Wei
    Wang, Xiao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [30] Simplification of head and neck volumetric modulated arc therapy patient-specific quality assurance, using a Delta4 PT
    Sasaki, Motoharu
    Sugimoto, Wataru
    Ikushima, Hitoshi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (05) : 793 - 800