Repositioning of Misplaced Central Venous Catheter with Saline Injection Under C-Arm Imaging

被引:4
|
作者
Gautam, Parshotam Lal [1 ]
Kundra, Sandeep [2 ]
Jain, Krishan [2 ]
Monga, Hitika [2 ]
机构
[1] DMC & H Ludhiana, Dept Crit Care Med, Ludhiana, Punjab, India
[2] DMC & H Ludhiana, Dept Anaesthesia, Ludhiana, Punjab, India
关键词
Central venous catheter; Malposition; Misplacement;
D O I
10.7860/JCDR/2015/15694.6930
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Malposition of central venous catheter is a well known technical complication. Misplaced catheter often requires reinsertion for proper placement of the catheter in the superior vena cava (SVC) to support safe delivery of care and minimize complications. But reinsertion exposes the patient once again to risks of complications related to the procedure including potential of misplacement. Literature describes only a few techniques for repositioning a misplaced central venous catheter (CVC). We tried old simple method of saline injection with force under image intensifier using hydrostatic force of intravenous fluid to straighten the CVC. We could successfully reposition two misplaced CVC's using this method.
引用
收藏
页码:UD01 / UD02
页数:2
相关论文
共 50 条
  • [31] Development of intraoperative C-arm imaging in trauma surgery
    Krettek, C.
    Gebhard, F.
    UNFALLCHIRURG, 2012, 115 (02): : 100 - 106
  • [32] C-arm CT Perfusion Imaging in the Interventional Suite
    Fieselmann, Andreas
    Manhart, Michael
    CURRENT MEDICAL IMAGING, 2013, 9 (02) : 96 - 101
  • [33] Closed Sinusoid Trajectory for C-Arm CT Imaging
    Yang, Haiquan
    Li, Meihua
    Koizumi, Kazuhito
    Kudo, Hiroyuki
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3480 - 3484
  • [34] Augmented reality-based feedback for technician-in-the-loop C-arm repositioning
    Unberath, Mathias
    Fotouhi, Javad
    Hajek, Jonas
    Maier, Andreas
    Osgood, Greg
    Taylor, Russell
    Armand, Mehran
    Navab, Nassir
    HEALTHCARE TECHNOLOGY LETTERS, 2018, 5 (05): : 143 - 147
  • [35] Hybrid closure of common carotid artery perforation caused by misplaced central venous catheter
    Paczkowski, Konrad
    Chojnicki, Maciej
    Sroka, Tomasz
    Paczkowska, Katarzyna
    Gierat-Haponiuk, Katarzyna
    Haponiuk, Ireneusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (04): : 440 - 441
  • [36] Needle targeting under C-arm fluoroscopy servoing
    Mihaescu, C
    Ibanez, L
    Mocanu, M
    Cleary, K
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 888 - 897
  • [37] Clinical effect of needle knife injection under C-arm X-ray-imaging guidance for the treatment of lumbar disc herniation
    Lu, Di
    Ding, Weiguo
    Sheng, Hongfeng
    Xu, Xinwei
    Xu, Bin
    Xu, Weixing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (09): : 10191 - 10198
  • [38] Agitated saline contrast to delineate central venous catheter position in neonates
    Upadhyay, Jaya
    Basu, Sriparna
    Srivastava, Yash
    Digal, Kanhu Charan
    Shubham, Shantanu
    Grover, Rajat
    Singh, Poonam
    JOURNAL OF PERINATOLOGY, 2021, 41 (07) : 1638 - 1644
  • [39] Respiratory Motion Compensation for C-Arm CT Liver Imaging
    Sindel, Aline
    Boegel, Marco
    Maier, Andreas
    Fahrig, Rebecca
    Hornegger, Joachim
    Doerfler, Arnd
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 221 - 226
  • [40] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208