Repositioning of Misplaced Central Venous Catheter with Saline Injection Under C-Arm Imaging

被引:4
|
作者
Gautam, Parshotam Lal [1 ]
Kundra, Sandeep [2 ]
Jain, Krishan [2 ]
Monga, Hitika [2 ]
机构
[1] DMC & H Ludhiana, Dept Crit Care Med, Ludhiana, Punjab, India
[2] DMC & H Ludhiana, Dept Anaesthesia, Ludhiana, Punjab, India
关键词
Central venous catheter; Malposition; Misplacement;
D O I
10.7860/JCDR/2015/15694.6930
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Malposition of central venous catheter is a well known technical complication. Misplaced catheter often requires reinsertion for proper placement of the catheter in the superior vena cava (SVC) to support safe delivery of care and minimize complications. But reinsertion exposes the patient once again to risks of complications related to the procedure including potential of misplacement. Literature describes only a few techniques for repositioning a misplaced central venous catheter (CVC). We tried old simple method of saline injection with force under image intensifier using hydrostatic force of intravenous fluid to straighten the CVC. We could successfully reposition two misplaced CVC's using this method.
引用
收藏
页码:UD01 / UD02
页数:2
相关论文
共 50 条
  • [21] CT Imaging with a mobile C-arm prototype
    Cheryauka, Arvi
    Tubbs, Dave
    Langille, Vinton
    Kalya, Prabhanjana
    Smith, Brady
    Cherone, Rocco
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [22] SIMPLY SALINE FOR CENTRAL VENOUS CATHETER FLUSH/LOCK
    Utech, Jane
    Hanrahan, Kirsten
    Bullard, Tacia
    Wagner, Michele
    ONCOLOGY NURSING FORUM, 2020, 47 (02)
  • [23] Brain imaging with a flat detector C-arm
    Soederman, M.
    Babic, D.
    Holmin, S.
    Andersson, T.
    NEURORADIOLOGY, 2008, 50 (10) : 863 - 868
  • [24] Fusion Imaging for EVAR with Mobile C-arm
    Kaladji, Adrien
    Villena, Alexandre
    Pascot, Remy
    Lalys, Florent
    Daoudal, Anne
    Clochard, Elodie
    Lucas, Antoine
    Cardon, Alain
    ANNALS OF VASCULAR SURGERY, 2019, 55 : 166 - 174
  • [25] Catheter localization using C-arm with flat-panel
    Meng, Cai
    Zhang, Jun
    Liu, Bo
    Wang, Lijun
    Gaojishu Tongxin/Chinese High Technology Letters, 2012, 22 (04): : 395 - 402
  • [26] Misplaced central venous catheter in the jugular venous arch exposed during dissection before sternotomy
    Jung, Tae-Eun
    Jee, Daelim
    JOURNAL OF CLINICAL ANESTHESIA, 2008, 20 (07) : 542 - 545
  • [27] Tracking a Magnetically Guided Catheter with a Single Rotating C-Arm
    Hong, Ayoung
    Fetruska, Andrew
    Nelson, Bradley J.
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 618 - 623
  • [28] Inadvertent Arterial Cannulation and Norepinephrine Infusion Due to a Misplaced Central Venous Catheter
    Al-Shareef, Ali S.
    Darweish, Aida
    Shirah, Bader
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [29] SPONTANEOUS MIGRATION OF A CENTRAL VENOUS CATHETER AND ITS REPOSITIONING - TECHNICAL NOTE
    WOLF, S
    ALBIN, MS
    WINNEM, B
    NEUROSURGERY, 1980, 6 (06) : 652 - 653
  • [30] Misplaced central venous catheter in the vertebral artery: endovascular treatment of foreseen hemorrhage during catheter withdrawal
    Akkan, Koray
    Cindil, Emetullah
    Kilic, Koray
    Ilgit, Erhan
    Onal, Baran
    Erbas, Gonca
    JOURNAL OF VASCULAR ACCESS, 2014, 15 (05): : 418 - 423