100-MHz ultrasonic linear array transducers based on polyurea-film

被引:5
|
作者
Nakazawa, Marie [1 ]
Tabaru, Masaya [1 ]
Takayasu, Toshiki [1 ]
Aoyagi, Takahiro [2 ]
Nakamura, Kentaro [1 ]
机构
[1] Tokyo Inst Technol, Precis & Intelligence Lab, Midori Ku, Nagatsuta Cho 4259, Yokohama, Kanagawa 2268503, Japan
[2] Tokyo Inst Technol, Grad Sch Decis Sci & Technol, Meguro Ku, Tokyo 1528552, Japan
基金
日本学术振兴会;
关键词
Polyurea film; Piezoelectric polymer; High-frequency; Ultrasonic array transducer; Phased array; Lithography;
D O I
10.1250/ast.36.139
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Eight- and 32-element ultrasonic array transducers using polyurea films are fabricated and experimentally tested in this study. Aromatic polyurea thin films, prepared by vapor deposition polymerization, are suitable for use as an ultrasonic transducer. In this paper, we present two types of polyurea array transducer with 20 and 200 mu m pitches. The polyurea films were prepared through vapor deposition polymerization, and miniature electrode arrays were fabricated by a lithographic technique. Resonance frequencies of approximately 30, 65, and 100 MHz were observed in the electrical admittance. To examine the performances of the prototype array transducers, a pulse/echo test and phased array experiment were performed. From the experimental results, we found that the polyurea array transducers fabricated by the proposed method correctly operated as expected.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [21] LOW-COST, MICROPROCESSOR-BASED, 100-MHZ UNIVERSAL COUNTER
    MASTERS, LW
    BLANKENSHIP, KM
    WARD, MJ
    HEWLETT-PACKARD JOURNAL, 1979, 30 (01): : 2 - &
  • [22] Research and Analysis on Ultrasonic Imaging Characteristics of CFRP Laminates Based on Linear and Annular Array Transducers
    Wang J.
    Zhou Z.
    Wang J.
    Liu Y.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2023, 59 (10): : 30 - 39
  • [23] A 100 MHz Multi-layered High Performance Transducer Using Polyurea Thin Film
    Nakazawa, Marie
    Maezawa, Akihiro
    Nakamura, Kentaro
    Ueha, Sadayuki
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2421 - +
  • [24] Preoperative ultrasonic assessment of thin melanocytic skin lesions using a 100-MHz ultrasound transducer: A comparative study
    Gambichler, Thilo
    Moussa, Georg
    Bahrenberg, Katharina
    Vogt, Michael
    Ermert, Helmut
    Weyhe, Dirk
    Altmeyer, Peter
    Hoffmann, Klaus
    DERMATOLOGIC SURGERY, 2007, 33 (07) : 818 - 824
  • [25] Development of a high frequency (35-MHz) linear ultrasonic array
    Cannata, JM
    Shung, KK
    MEDICAL IMAGING 2004: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2004, 5373 : 18 - 23
  • [26] A 100-MHZ ULTRASONIC DELAY-LINE LOOP AND ITS USE AS A 1000 - 1 BIT RATE CONVERTER
    HEITER, GL
    DAMRON, RF
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1970, SU17 (01): : 62 - &
  • [28] Demonstration of MHz piezoelectric micromachined ultrasonic transducers array and its potential application for biomedical treatment
    Wang, Dengke
    Ji, Yucheng
    Wang, Shaokun
    Zhang, Songsong
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2024, 34 (03)
  • [29] DEMONSTRATION OF MHZ PIEZOELECTRIC MICROMACHINED ULTRASONIC TRANSDUCERS (PMUTS) ARRAY AND THE POTENTIAL APPLICATION IN BIOMEDICAL THERAPIES
    Wang, Dengke
    Ji, Yucheng
    Wang, Shaokun
    Lyu, Haochen
    Zhang, Songsong
    2024 IEEE 37TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2024, : 955 - 958
  • [30] PROPERTIES OF A PVDF HYDROPHONE WITH 100-MHZ BANDWIDTH FOR STUDYING MEDICAL, NON-LINEAR AND OTHER FIELDS
    BACON, DR
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1981, 28 (05): : 361 - 361