COMPARISON OF LATTICE-PARAMETERS OBTAINED FROM AN INTERNAL SILICON MONOCRYSTAL STANDARD

被引:11
|
作者
HARTWIG, J
BAKMISIUK, J
BERGER, H
BRUHL, HG
OKADA, Y
GROSSWIG, S
WOKULSKA, K
WOLF, J
机构
[1] POLISH ACAD SCI,INST PHYS,PL-02668 WARSAW,POLAND
[2] HUMBOLDT UNIV BERLIN,INST KRISTALLOG & MAT FORSCH,FACHBEREICH PHYS,D-10099 BERLIN,GERMANY
[3] FRIEDRICH SCHILLER UNIV JENA,INST OPT & QUANTENELEKTRON,D-07743 JENA,GERMANY
[4] UNIV LEIPZIG,SEKT PHYS,D-04103 LEIPZIG,GERMANY
[5] SILESIAN UNIV,INST PHYS & CHEM MET,PL-40007 KATOWICE,POLAND
[6] ELECTROTECH LAB,DIV PHYS SCI,TSUKUBA 305,JAPAN
来源
关键词
D O I
10.1002/pssa.2211420103
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The lattice parameter of a highly perfect monocrystalline silicon sample is measured in six laboratories using three different diffraction methods. The quality of the measurements and of the applied corrections is already sufficiently high to compare lattice parameters measured by means of the used methods and CuKalpha radiation on an absolute scale with an accuracy of about DELTAa/a = 3 x 10(-6).
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [41] NUMERICAL EVALUATION OF LATTICE-PARAMETERS FROM HIGH-ORDER LAUE ZONE LINES IN CONVERGENT-BEAM ELECTRON-DIFFRACTION DISKS
    DEBLASI, C
    DIGIULIO, M
    MANNO, D
    ULTRAMICROSCOPY, 1988, 26 (04) : 377 - 384
  • [42] TEMPERATURE-DEPENDENCE OF MNF2 AND KMNF3 LATTICE-PARAMETERS FROM ROOM-TEMPERATURE TO MELTING-POINT
    DORMANN, E
    COPLEY, JRD
    JACCARINO, V
    JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (15): : 2767 - 2771
  • [43] Comparison of Retinal Nerve Fiber Layer Thickness obtained by HRT and Functional Parameters by Standard Automated Perimeter in Diagnosis of Glaucoma
    Ahmad, Chaudary Nasir
    Shah, Syed Raza Ali
    Yousif, Ateeq
    Khan, Asad Aslam
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2011, 5 (01): : 26 - 29
  • [44] A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography
    Marik, PE
    Pendelton, JE
    Smith, R
    CRITICAL CARE MEDICINE, 1997, 25 (09) : 1545 - 1550
  • [45] On comparison of the Earth orientation parameters obtained from different VLBI networks and observing programs
    Malkin, Z.
    JOURNAL OF GEODESY, 2009, 83 (06) : 547 - 556
  • [46] Comparison of the heart rate variability parameters obtained from the electrocardiogram and the blood pressure wave
    Carrasco, S
    Gonzalez, R
    Jimenez, J
    Roman, R
    Medina, V
    Azpiroz, J
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1998, 22 (05) : 195 - 205
  • [47] On comparison of the Earth orientation parameters obtained from different VLBI networks and observing programs
    Z. Malkin
    Journal of Geodesy, 2009, 83 : 547 - 556
  • [48] PRECISE X-RAY RELATIVE MEASUREMENT OF LATTICE-PARAMETERS OF SILICON-WAFERS BY MULTIPLE-CRYSTAL BRAGG-CASE DIFFRACTOMETRY - COMPUTER-SIMULATION OF THE EXPERIMENT
    CEMBALI, F
    FABBRI, R
    SERVIDORI, M
    ZANI, A
    BASILE, G
    CAVAGNERO, G
    BERGAMIN, A
    ZOSI, G
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1992, 25 : 424 - 431
  • [50] Quantitative and recyclable SERS detection induced by tunable Raman internal standard from embedded silicon nanoparticles
    Jiang J.
    Xu L.
    Zhang Y.
    Ma J.
    Gu C.
    Zhou X.
    Wei G.
    Jiang T.
    Sensors and Actuators B: Chemical, 2022, 366