COMPARISON OF LATTICE-PARAMETERS OBTAINED FROM AN INTERNAL SILICON MONOCRYSTAL STANDARD

被引:11
|
作者
HARTWIG, J
BAKMISIUK, J
BERGER, H
BRUHL, HG
OKADA, Y
GROSSWIG, S
WOKULSKA, K
WOLF, J
机构
[1] POLISH ACAD SCI,INST PHYS,PL-02668 WARSAW,POLAND
[2] HUMBOLDT UNIV BERLIN,INST KRISTALLOG & MAT FORSCH,FACHBEREICH PHYS,D-10099 BERLIN,GERMANY
[3] FRIEDRICH SCHILLER UNIV JENA,INST OPT & QUANTENELEKTRON,D-07743 JENA,GERMANY
[4] UNIV LEIPZIG,SEKT PHYS,D-04103 LEIPZIG,GERMANY
[5] SILESIAN UNIV,INST PHYS & CHEM MET,PL-40007 KATOWICE,POLAND
[6] ELECTROTECH LAB,DIV PHYS SCI,TSUKUBA 305,JAPAN
来源
关键词
D O I
10.1002/pssa.2211420103
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The lattice parameter of a highly perfect monocrystalline silicon sample is measured in six laboratories using three different diffraction methods. The quality of the measurements and of the applied corrections is already sufficiently high to compare lattice parameters measured by means of the used methods and CuKalpha radiation on an absolute scale with an accuracy of about DELTAa/a = 3 x 10(-6).
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [21] DETERMINING THE 3D LATTICE-PARAMETERS OF NANOMETER-SIZED SINGLE-CRYSTALS FROM IMAGES
    FRAUNDORF, P
    ULTRAMICROSCOPY, 1987, 22 (1-4) : 225 - 229
  • [22] Inter-comparison of lattice parameters and evaluation of peak-shift obtained by Rietveld refinements
    Tsubota, Masami
    Paik, Biswajit
    Kitagawa, Jiro
    RESULTS IN PHYSICS, 2019, 15
  • [23] LATTICE-PARAMETERS AND THERMAL-EXPANSION OF DELTA-VN1-X FROM 298-1000-K
    LENGAUER, W
    ETTMAYER, P
    MONATSHEFTE FUR CHEMIE, 1986, 117 (6-7): : 713 - 719
  • [24] CRYSTAL-CHEMISTRY AND LATTICE-PARAMETERS OF ARDENNITES FROM ANDROS ISLAND, GREECE, AND HAUTE-MAURIENNE, WESTERN ALPS
    REINECKE, T
    HATZIPANAGIOTOU, K
    NEUES JAHRBUCH FUR MINERALOGIE-ABHANDLUNGEN, 1987, 158 (01): : 89 - 104
  • [25] Accuracy of pulse rate variability parameters obtained from finger plethysmogram: A comparison with heart rate variability parameters obtained from ECG
    Kageyama, T
    Kabuto, M
    Kaneko, T
    Nishikido, N
    JOURNAL OF OCCUPATIONAL HEALTH, 1997, 39 (02) : 154 - 155
  • [26] A NEW LEAST-SQUARES METHOD FOR DETERMINATION OF LATTICE-PARAMETERS FROM POWDER X-RAY-DIFFRACTION DATA
    KANEKO, T
    GONG, SK
    NITTONO, O
    TRANSACTIONS OF THE JAPAN INSTITUTE OF METALS, 1987, 28 (02): : 95 - 101
  • [27] A comparison of oxygen saturation measurements obtained from a 'blue sensor' with a standard sensor
    Mawson, Isabel E.
    Dawson, Jennifer A.
    Donath, Susan M.
    Davis, Peter G.
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2011, 47 (10) : 693 - 697
  • [28] Comparison of walking parameters obtained from the young, elderly and adults with support
    Acharya, U. Rajendra
    Sree, S. Vinitha
    Lim, Choo Min
    Ang, Peng Chuan Alvin
    Sekine, Masaki
    Tamura, Toshiyo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (11) : 1202 - 1212
  • [29] LATTICE-PARAMETERS OF SOME THCU2SI2-TYPE PHASES IN TERNARY ALLOYS OF RARE-EARTHS WITH COBALT (OR IRON) AND SILICON (OR GERMANIUM)
    ROSSI, D
    MARAZZA, R
    FERRO, R
    JOURNAL OF THE LESS-COMMON METALS, 1978, 58 (02): : 203 - 207
  • [30] Comparison of the characteristics of solar cells fabricated from multicrystalline silicon with those fabricated from silicon obtained by the monolike technology
    Betekbaev, A. A.
    Mukashev, B. N.
    Pelissier, L.
    Lay, P.
    Fortin, G.
    Bounaas, L.
    Skakov, D. M.
    Kalygulov, D. A.
    Turmagambetov, T. S.
    Lee, V. V.
    SEMICONDUCTORS, 2016, 50 (08) : 1085 - 1091