FRINGE MODE TRANSMITTANCE LASER DOPPLER MICROSCOPE ANEMOMETER - ITS ADAPTATION FOR MEASUREMENT IN THE MICROCIRCULATION

被引:5
|
作者
EINAV, S [1 ]
BERMAN, HJ [1 ]
机构
[1] BOSTON UNIV,CTR BIOL SCI,BOSTON,MA 02215
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1988年 / 10卷 / 05期
关键词
Anemometers--Laser Doppler - Flow of Fluids--Suspensions - Interferometry--Computer Applications - Laser Beams--Interference;
D O I
10.1016/0141-5425(88)90141-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood flow analysis in the microcirculation requires accurate measurement of velocity, volume flow and shear-rate versus shear-stress relationships. The resolutions of most anemometers is too limited to obtain useful measurements, especially near the blood vessel wall and at branches and bifurcations. To make such measurements possible with a noninvasive, high-resolution, accurate technique the authors have developed a fringe mode, transmittance laser Doppler microscope anemometer (LDMA). This system has an intrinsically high spatial resolution (10×12μm), and does not require a high concentration (106/cm3) of scatterers or red blood cells. Preliminary measurements of water flow in a rectangular channel were conducted to ascertain the reliability and accuracy of velocity measurements using the LDMA. Velocity profiles were then measured by the LDMA system in arterioles 38-135μm in diameter, in the transparent, everted check pouch of the anaesthetized hamster. The extremely high resolution of the optical system, and the ultrafine traversing mechanism of the microscope stage, made velocity readings larger than 0.02 mm/s with accuracy and reproducibility better than 1% possible near the wall to within 7-10μm.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
  • [41] Pilot Study of Laser Doppler Measurement of Flow Variability in the Microcirculation of the Palatal Mucosa
    Le Bars, Pierre
    Niagha, Gaston
    Kouadio, Ayepa Alain
    Demoersman, Julien
    Roy, Elisabeth
    Armengol, Valerie
    Soueidan, Assem
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [42] Measurement of the skin microcirculation through intact bandages using laser Doppler flowmetry
    J. M. Melhuish
    L. Krishnamoorthy
    T. Bethaves
    M. Clark
    R. J. Williams
    K. G. Harding
    Medical and Biological Engineering and Computing, 2004, 42 : 259 - 263
  • [43] Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser doppler flowmetry
    Yaoeda, K
    Shirakashi, M
    Funaki, S
    Funaki, H
    Abe, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S489 - S489
  • [44] Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser Doppler flowmetry
    Yaoeda, K
    Shirakashi, M
    Funaki, S
    Funaki, H
    Nakatsue, T
    Abe, H
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (06) : 734 - 739
  • [45] Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation
    Hu, Chang-Lin
    Lin, Zhan-Sheng
    Chen, Yen-Yu
    Lin, Yuan-Hsiang
    Lai, Mei-Feng
    Li, Meng-Lin
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2012, 22 (06) : 351 - 359
  • [46] LASER DOPPLER MICROSCOPE - ITS SIGNAL-ANALYZING SYSTEMS
    MISHINA, H
    TOKUI, S
    USHIZAKA, T
    ASAKURA, T
    NAGAI, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 : 323 - 328
  • [47] LASER-SCANNING MODE INTERFERENCE CONTRAST MICROSCOPE AND ITS APPLICATION TO STEP HEIGHT MEASUREMENT
    OOKI, H
    ARIMOTO, R
    SHIONOYA, T
    MATSUURA, K
    IWASAKI, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (11A): : 4998 - 5001
  • [48] A single-headed fibre optic laser Doppler anemometer probe for the measurement of flow angles
    Byrne, GD
    James, SW
    Tatam, RP
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (01) : 1 - 8
  • [49] INFLUENCE OF VALIDATION SCHEMES IN A LASER DOPPLER ANEMOMETER PERIOD TIMING DEVICE FOR FREQUENCY-MEASUREMENT
    VENKATESH, P
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (05): : 587 - 592
  • [50] Quantitative measurement of gastric mucosal microcirculation using a combined laser Doppler flowmeter and spectrophotometer
    Bludau, M.
    Vallboehmer, D.
    Gutschow, C.
    Hoelscher, A. H.
    Schroeder, W.
    DISEASES OF THE ESOPHAGUS, 2008, 21 (07) : 668 - 672