POSTERIOR CHAMBER INTRAOCULAR-LENS IMPLANTATION IN FILTERED OR NONFILTERED GLAUCOMA EYES

被引:0
|
作者
YAMAGAMI, S
ARAIE, M
MORI, M
MISHIMA, K
机构
[1] UNIV TOKYO,BRANCH HOSP,SCH MED,DEPT OPHTHALMOL,TOKYO,JAPAN
[2] TOKYO METROPOLITAN GERIATR HOSP & INST GERONTOL,EYE CLIN,TOKYO,JAPAN
[3] KANTO ROUSAI HOSP,EYE CLIN,KAWASAKI,KANAGAWA,JAPAN
关键词
CATARACT; GLAUCOMA; INTRAOCULAR PRESSURE CONTROL; LIFE-TABLE METHOD; POSTERIOR CHAMBER INTRAOCULAR LENS IMPLANTATION;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Cataract extraction and posterior chamber intraocular lens (PC-IOL) implantation was carried out in 45 glaucoma eyes that had undergone glaucoma filtering surgery (Group A), and in 47 glaucoma eyes in which intraocular pressure (IOP) was well controlled with medication (Group B). To analyze the effects of PC-IOL implantation on the control of IOP and the functioning of the filtering bleb, a life-table analysis using the Kaplan-Meier method was carried out. In Group A the probability that IOP control will not worsen at 2 years was 56 +/- 12 (SE) % in eyes where a functioning filtering bleb had existed preoperatively. The probability that the filtering bleb was not cicatrized at 2 years postoperatively was 44 +/- 11 (SE) %. In Group B the postoperative IOP on the first postoperative day was significantly higher than the preoperative level in primary open angle glaucoma (POAG) eyes, while no such difference was seen in primary angle closure glaucoma (PACG) eyes. The postoperative IOP was significantly lower than the preoperative level from 3 to 6 months postoperatively in POAG eyes and from 1 to 12 months postoperatively in PACG eyes. Medication did not differ significantly pre- and postoperatively. In 64 +/- 11 (SE) % of POAG and 63 +/- 15% Of PACG eyes the IOP control did not worsen at 2 years. In 70% of the eyes the IOP control improved postoperatively, and was maintained for 2 years with the probability of 44 +/- 12 (SE) %.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 50 条
  • [31] POSTERIOR CHAMBER INTRAOCULAR-LENS DISLOCATIONS AND MALPOSITIONS
    OBSTBAUM, SA
    TO, K
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1989, 17 (03): : 265 - 271
  • [32] INTRAOCULAR-LENS IMPLANTATION IN PHAKIC RABBIT EYES
    TCHAH, H
    DUFFEY, RJ
    ALLARAKHIA, L
    LINDSTROM, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (05): : 554 - 558
  • [33] GLAUCOMA AND ITS RELATIONSHIP TO INTRAOCULAR-LENS IMPLANTATION
    OBSTBAUM, SA
    ORLANDO, F
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1989, 17 (03): : 303 - 308
  • [34] CAPSULAR BAG DISTENSION AFTER ENDOPHACOEMULSIFICATION AND POSTERIOR CHAMBER INTRAOCULAR-LENS IMPLANTATION
    DAVISON, JA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01): : 99 - 108
  • [35] SUTURE TO LIMBUS DISTANCES IN EYES WITH A POSTERIOR CHAMBER INTRAOCULAR-LENS IMPLANTED BY SCLERAL FIXATION
    LEE, JH
    CHANG, JH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (02): : 278 - 283
  • [36] POSTERIOR CHAMBER LENS IMPLANTATION IN GLAUCOMA
    WEICKERT, C
    NOVER, A
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 190 (05) : 458 - 458
  • [37] FLUOROPHOTOMETRY IN PHAKIC EYES WITH ANTERIOR-CHAMBER INTRAOCULAR-LENS IMPLANTATION TO CORRECT MYOPIA
    DELCASTILLO, JMB
    HERNANDEZ, JL
    IRADIER, MT
    DELRIO, MT
    SANCHEZ, JG
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05): : 607 - 609
  • [38] ECHOGRAPHY OF THE POSTERIOR LENS CAPSULE PRIOR TO IMPLANTATION OF AN INTRAOCULAR-LENS
    CLEMENS, S
    KROLL, P
    BUSSE, H
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 191 (02) : 110 - 112
  • [39] CILIARY SULCUS SUTURING OF A POSTERIOR CHAMBER INTRAOCULAR-LENS
    NABORS, G
    VARLEY, MP
    CHARLES, S
    OPHTHALMIC SURGERY AND LASERS, 1990, 21 (04): : 263 - 265
  • [40] SCLERAL FIXATION OF A SUBLUXATED POSTERIOR CHAMBER INTRAOCULAR-LENS
    GIRARD, LJ
    NINO, N
    WESSON, M
    MAGHRABY, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (03): : 326 - 327