CILIARY SULCUS SUTURING OF A POSTERIOR CHAMBER INTRAOCULAR-LENS

被引:0
|
作者
NABORS, G [1 ]
VARLEY, MP [1 ]
CHARLES, S [1 ]
机构
[1] CTR RETINA VITREOUS SURG,6401 POPLAR AVE,SUITE 190,MEMPHIS,TN 38119
来源
OPHTHALMIC SURGERY AND LASERS | 1990年 / 21卷 / 04期
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
引用
收藏
页码:263 / 265
页数:3
相关论文
共 50 条
  • [1] IDENTIFYING THE CILIARY SULCUS FOR SUTURING A POSTERIOR CHAMBER INTRAOCULAR-LENS BY TRANSILLUMINATION
    HORIGUCHI, M
    HIROSE, H
    KOURA, T
    SATOU, M
    ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (12) : 1693 - 1695
  • [2] SIMPLIFIED TECHNIQUE FOR SUTURING DISLOCATED POSTERIOR CHAMBER INTRAOCULAR-LENS TO THE CILIARY SULCUS
    ANAND, R
    BOWMAN, RW
    ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (09) : 1205 - 1206
  • [3] TRANSCLERAL CILIARY SULCUS FIXATION OF POSTERIOR CHAMBER INTRAOCULAR-LENS IMPLANTS
    AGAPITOS, PJ
    LINDSTROM, RL
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1989, 17 (02): : 169 - 172
  • [4] CILIARY SULCUS FIXATION OF A DISLOCATED POSTERIOR CHAMBER INTRAOCULAR-LENS USING LIQUID PERFLUOROPHENANTHRENE
    FANOUS, MM
    FRIEDMAN, SM
    OPHTHALMIC SURGERY AND LASERS, 1992, 23 (08): : 551 - 552
  • [5] PATHOLOGIC EXAMINATION OF A J-LOOP POSTERIOR CHAMBER INTRAOCULAR-LENS IN THE CILIARY SULCUS
    HOFFER, KJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1981, 92 (02) : 268 - 272
  • [6] ANATOMIC VIEW OF THE CILIARY SULCUS WITH THE ANTERIOR SEGMENT MIRROR DURING SUTURED POSTERIOR CHAMBER INTRAOCULAR-LENS
    TSAI, JC
    ROWSEY, JJ
    FOURAKER, BD
    STEVENS, SX
    BOWYER, BL
    YOUNG, DA
    POLACK, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S502 - S502
  • [7] INSERTION OF POSTERIOR CHAMBER INTRAOCULAR-LENS
    HARBIN, RL
    MATTINGLY, TP
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (04) : 560 - 561
  • [8] CHRONIC CILIARY PAIN SECONDARY TO POSTERIOR CHAMBER INTRAOCULAR-LENS LOOP INCARCERATION
    LEGLER, UFC
    APPLE, DJ
    HUND, P
    KIRKCONNELL, WS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (04) : 513 - 515
  • [9] REPOSITIONING A TILTED CILIARY-SULCUS-FIXATED INTRAOCULAR-LENS
    BERGER, RR
    KENYERES, A
    VANCOLLER, BM
    PRETORIUS, CF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (05): : 497 - 498
  • [10] Clinical Comparison of Ciliary Sulcus or Ciliary Body Localization in Transcleral Fixation of Posterior Chamber Intraocular Lens
    Ma, D.
    Kim, M.
    Wee, W.
    Lee, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)