CALCULATED RESPONSE OF INTRINSIC GERMANIUM DETECTORS TO NARROW BEAMS OF PHOTONS WITH ENERGIES UP TO - 300 KEV

被引:0
|
作者
SELTZER, SM
机构
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH | 1981年 / 188卷 / 01期
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:133 / 151
页数:19
相关论文
共 39 条
  • [32] HIGH-CURRENT METAL-ION BEAMS WITH ENERGIES UP TO 45 KEV U-1
    EMIG, H
    RUCK, DM
    SPADTKE, P
    WOLF, BH
    TORP, B
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1989, 116 : 209 - 213
  • [33] CHARGE-COUPLED-DEVICE RESPONSE TO ELECTRON-BEAM ENERGIES OF LESS THAN 1 KEV UP TO 20 KEV
    DAUD, T
    JANESICK, JR
    EVANS, K
    ELLIOTT, T
    OPTICAL ENGINEERING, 1987, 26 (08) : 686 - 691
  • [34] Development of a computer code using the EGS4 Monte Carlo simulation system to evaluate the response of a NaI(T1) detector to photons with energies below 300 keV
    Al-Ghorabie, FHH
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) : 85 - 92
  • [35] The response of thick (10μm) AlInP x-ray and γ-ray detectors at up to 88keV
    Lioliou, G.
    Butera, S.
    Krysa, A. B.
    Barnett, A. M.
    JOURNAL OF APPLIED PHYSICS, 2021, 129 (24)
  • [36] High Voltage-Cylinder Sector Analyzer 300/15: A cylindrical sector analyzer for electron kinetic energies up to 15 keV
    Rubio-Zuazo, J.
    Escher, M.
    Merkel, M.
    Castro, G. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (04):
  • [37] Response of germanium detectors for high-energy γ-rays by 27Al(p, γ)28Si at Ep=992 keV
    Mizuno, Rurie
    Niikura, Megumi
    Ikeda, Tokihiro
    Matsuzaki, Teiichiro
    Go, Shintaro
    Saito, Takeshi Y.
    Michimasa, Shin'ichiro
    Sakurai, Hiroyoshi
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2023, 2023 (05):
  • [38] X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV
    Kurkova, Dana
    Judas, Libor
    RADIATION MEASUREMENTS, 2016, 85 : 64 - 72