CALCULATED RESPONSE OF INTRINSIC GERMANIUM DETECTORS TO NARROW BEAMS OF PHOTONS WITH ENERGIES UP TO - 300 KEV

被引:0
|
作者
SELTZER, SM
机构
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH | 1981年 / 188卷 / 01期
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:133 / 151
页数:19
相关论文
共 39 条
  • [21] An analytical X-ray CdTe detector response matrix for incomplete charge collection correction for photon energies up to 300 keV
    Kurkova, Dana
    Judas, Libor
    RADIATION PHYSICS AND CHEMISTRY, 2018, 146 : 26 - 33
  • [22] RESPONSE LINEARITY OF NB TUNNEL JUNCTION DETECTORS FOR PHOTON ENERGIES FROM 1.5 TO 6.4 KEV
    RANDO, N
    PEACOCK, A
    VANDORDRECHT, A
    HUBNER, P
    VIDELER, P
    SALMI, J
    SUNI, I
    JOURNAL OF APPLIED PHYSICS, 1994, 76 (04) : 2490 - 2493
  • [23] INVESTIGATIONS OF THE RESPONSE OF GERMANIUM DETECTORS TO MONOENERGETIC ELECTRON, POSITRON AND GAMMA-RAY BEAMS
    VARLEY, BJ
    KITCHING, JE
    LEO, W
    MISKIN, J
    MOORE, RB
    WUNSCH, KD
    DECKER, R
    WOLLNIK, H
    SIEGERT, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (03): : 543 - 554
  • [24] Fast neutron detection with germanium detectors: Unfolding the 692 keV peak response for fission neutron spectra
    Fehrenbacher, G
    Meckbach, R
    Paretzke, HG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 397 (2-3): : 391 - 398
  • [25] Fast neutron detection with germanium detectors: computation of response functions for the 692 keV inelastic scattering peak
    Fehrenbacher, G.
    Meckbach, R.
    Paretzke, H.G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 372 (1-2): : 239 - 245
  • [26] Fast neutron detection with germanium detectors: Computation of response functions for the 692 keV inelastic scattering peak
    Fehrenbacher, G
    Meckbach, R
    Paretzke, HG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (1-2): : 239 - 245
  • [27] Fast neutron detection with germanium detectors: Unfolding the 692 keV peak response for fission neutron spectra
    GSF - Natl Research Cent for, Environment and Health, Neuherberg, Germany
    Nucl Instrum Methods Phys Res Sect A, 2-3 (391-398):
  • [28] Development and commissioning of ion-optical elements for ion and antiproton beams with energies up to 5 keV
    Klink, C.
    Schlaich, M.
    Fischer, J.
    Obertelli, A.
    Schmidt, A.
    Wienholtz, F.
    Journal of Instrumentation, 2024, 19 (11)
  • [29] FLUORESCENT RESPONSE OF NAI(TL) AND CSI(TL) CRYSTALS TO HEAVY IONS OF ENERGIES 1 TO 300 KEV
    CANO, GL
    LOCKWOOD, GJ
    PHYSICAL REVIEW, 1967, 157 (03): : 677 - &
  • [30] Personal dose equivalent angular response factors for photons with energies up to 1 GeV
    Veinot, K. G.