Analysis of combined low-level indicators for the hot-season performance of roof components

被引:0
|
作者
Lodi, Chiara [1 ]
Muscio, Alberto [1 ]
Tartarini, Paolo [1 ]
Akbari, Hashem [2 ]
机构
[1] Univ Modena & Reggio Emilia, Modena, Italy
[2] Concordia Univ, Montreal, PQ, Canada
关键词
Albedo; Building cooling; Periodic thermal transmittance; R-value; Solar absorptance; Solar factor; Solar reflectance; Solar transmittance factor; Solar transmittance index; U-value;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A single performance indicator, the solar transmittance factor (STF), has been proposed in previous works, together with the derived solar transmittance index (STI). It is aimed at evaluating the summer performance of the roofing system and allowing the selection of the most effective mix of surface and mass properties. It is easily calculated from low-level indicators such as U-value, module of periodic thermal transmittance, and solar reflectance. In the present work, the correlation between STF and the cooling energy demand, integrated over a reference period, was studied, as well as the peak of ceiling temperature increase with respect to the indoor temperature, relevant for thermal comfort. In particular, the thermal behavior of different roof types with variable insulation was calculated numerically by TRNSYS 17 for a wide set of locations and environmental conditions. Unlike other commonly used indicators, to which the analysis has been extended, a strong correlation with STF was found for both cooling energy demand and ceiling temperature rise. (c) 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Chaco low-level jet events characterization during the austral summer season
    Salio, P
    Nicolini, M
    Saulo, AC
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2002, 107 (D24) : XLXIII - XLXIV
  • [32] Predictive monitoring of temporally-aggregated performance indicators of business processes against low-level streaming events
    Cuzzocrea, Alfredo
    Folino, Francesco
    Guarascio, Massimo
    Pontieri, Luigi
    INFORMATION SYSTEMS, 2019, 81 : 236 - 266
  • [33] The Strong on the Roof. Function and Importance of the low-level Water Spout in ancient Egypt
    Bojowald, Stefan
    ARCHIV ORIENTALNI, 2016, 84 (02) : 447 - 449
  • [34] Low-level chlorine analysis by amperometric titration
    Brooks, A.S.
    Seegert, G.L.
    Journal of the Water Pollution Control Federation, 1979, 51 (11): : 2636 - 2640
  • [35] LOW-LEVEL ENVIRONMENTAL MONITORING BY FLUCTUATIONS ANALYSIS
    THIE, JA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (01): : 84 - &
  • [36] LOW-LEVEL ENVIRONMENTAL MONITORING BY FLUCTUATIONS ANALYSIS
    THIE, JA
    NUCLEAR SAFETY, 1973, 14 (02): : 105 - 110
  • [37] Practical and accurate low-level pointer analysis
    Guo, BL
    Bridges, MJ
    Triantafyllis, S
    Ottoni, G
    Raman, E
    August, DI
    CGO 2005: INTERNATIONAL SYMPOSIUM ON CODE GENERATION AND OPTIMIZATION, 2005, : 291 - 302
  • [38] LOW-LEVEL COUNTING APPLICATIONS TO METEORITE ANALYSIS
    SCHMITT, RA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 24 - &
  • [39] LOW-LEVEL ABSORPTION MICROSCOPE IMAGE ANALYSIS
    CASPERSSON, T
    SENNERSTAM, R
    EXPERIMENTAL CELL RESEARCH, 1975, 92 (02) : 333 - 338
  • [40] Impact of high and low-level capabilities on bank performance
    Garrab, Mehdi Younes
    Yahyaoui, Abdelkarim
    INTERNATIONAL JOURNAL OF ADVANCED AND APPLIED SCIENCES, 2025, 12 (02): : 91 - 100