Analysis of combined low-level indicators for the hot-season performance of roof components

被引:0
|
作者
Lodi, Chiara [1 ]
Muscio, Alberto [1 ]
Tartarini, Paolo [1 ]
Akbari, Hashem [2 ]
机构
[1] Univ Modena & Reggio Emilia, Modena, Italy
[2] Concordia Univ, Montreal, PQ, Canada
关键词
Albedo; Building cooling; Periodic thermal transmittance; R-value; Solar absorptance; Solar factor; Solar reflectance; Solar transmittance factor; Solar transmittance index; U-value;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A single performance indicator, the solar transmittance factor (STF), has been proposed in previous works, together with the derived solar transmittance index (STI). It is aimed at evaluating the summer performance of the roofing system and allowing the selection of the most effective mix of surface and mass properties. It is easily calculated from low-level indicators such as U-value, module of periodic thermal transmittance, and solar reflectance. In the present work, the correlation between STF and the cooling energy demand, integrated over a reference period, was studied, as well as the peak of ceiling temperature increase with respect to the indoor temperature, relevant for thermal comfort. In particular, the thermal behavior of different roof types with variable insulation was calculated numerically by TRNSYS 17 for a wide set of locations and environmental conditions. Unlike other commonly used indicators, to which the analysis has been extended, a strong correlation with STF was found for both cooling energy demand and ceiling temperature rise. (c) 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Low-level library analysis and summarization
    Gopan, Denis
    Reps, Thomas
    COMPUTER AIDED VERIFICATION, PROCEEDINGS, 2007, 4590 : 68 - +
  • [22] STATIC ANALYSIS OF LOW-LEVEL SYNCHRONIZATION
    CALLAHAN, D
    SUBHLOK, J
    SIGPLAN NOTICES, 1989, 24 (01): : 100 - 111
  • [23] Analysis of low-level turbidity measurements
    Hart, Vincent S., 1600, (84):
  • [24] Shape analysis for low-level code
    Yang, Hongseok
    STATIC ANALYSIS, PROCEEDINGS, 2006, 4134 : 280 - 280
  • [26] Performance analysis for disposal of mixed low-level waste. I: Methodology
    Waters, RD
    Gruebel, MM
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1999, 125 (03): : 249 - 257
  • [27] Performance analysis for disposal of mixed low-level waste. I: Methodology
    Sandia National Lab., P.O. Box 5800, Albuquerque, NM 87185-1395, United States
    不详
    J. Environ. Eng., 3 (249-257):
  • [28] Performance analysis for disposal of mixed low-level waste. II: Results
    Waters, RD
    Gruebel, MM
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1999, 125 (03): : 258 - 266
  • [29] Performance analysis for disposal of mixed low-level waste. II: Results
    Sandia National Lab., P.O. Box 5800, Albuquerque, NM 87185-1395, United States
    不详
    J. Environ. Eng., 3 (258-266):
  • [30] Dobutamine combined with low-level exercise for myocardial perfusion scintigraphy
    Aydin, M
    Caner, B
    Yildirir, A
    Sari, O
    Tokgozoglu, L
    NUCLEAR MEDICINE COMMUNICATIONS, 2000, 21 (11) : 1015 - 1020