ARRAYS FOR AIRBORNE 100 KHZ ULTRASOUND

被引:18
|
作者
MUNRO, WSH
WYKES, C
机构
[1] Department of Manufacturing Engineering and Operations Management, University of Nottingham, Nottingham, NG7 2RD, University Park
关键词
PHASED ARRAYS; CAPACITIVE TRANSDUCERS; AIRBORNE ULTRASOUND;
D O I
10.1016/0041-624X(94)90081-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An investigation into methods of producing ultrasonic phased arrays resonating at 100 kHz using capacitive transducers is described here. The backplate texture is one of the most critical parameters determining the performance of these transducers, and transducer arrays were produced using a variety of methods to generate an appropriate backplate texture, including etching, chemical machining, silk-screening, shot-peening and machining. The most successful method involved the use of a proprietary conductive plant, and several arrays with both lambda and lambda/2 element spacings were produced and tested. The transducers can detect targets at distances of up to 1.8 m and two-dimensional range maps were constructed from the received signals using digital beam-forming.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [31] SCHOTTKY DIODES SHINE ABOVE 100 KHZ
    不详
    ELECTRONIC ENGINEER, 1972, 31 (06): : 15 - &
  • [32] Trains and Isolated Attosecond Pulses at 100 kHz
    Furch, Federico J.
    Witting, Tobias
    Osolodkov, Mikhail
    Schell, Felix
    Menoni, Carmen S.
    Schulz, Claus P.
    Vrakking, Marc J. J.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [33] Comparison of 60-kHz and 100-kHz wirebonding on organic and inorganic substances
    Charles, HK
    Mach, KJ
    Lehtonen, SJ
    Francomacaro, AS
    DeBoy, JS
    Edwards, RL
    2002 INTERNATIONAL SYMPOSIUM ON MICROELECTRONICS, PROCEEDINGS, 2002, 4931 : 470 - 477
  • [34] PIEZOMAGNETIC ULTRASOUND ALCOFER 44 KHZ TRANSDUCERS
    KACZKOWSKI, Z
    ULTRASONICS, 1987, 25 (06) : 376 - 377
  • [35] Electromagnetic bioinformation in the frequency region between 100 Hz and 100 kHz?
    Klima, H
    Lipp, B
    Lahrmann, H
    Bachtik, M
    FORSCHENDE KOMPLEMENTARMEDIZIN, 1998, 5 (05): : 230 - 235
  • [36] A Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz
    Lucev, Zeljka
    Krois, Igor
    Cifrek, Mario
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (12) : 3280 - 3289
  • [37] RESPONSE OF SHARKS TO CAVITATING ULTRASOUND AT 20 KHZ
    FISHMAN, SS
    TESTER, AL
    PROCEEDINGS OF THE WESTERN PHARMACOLOGY SOCIETY, 1970, 13 : 204 - +
  • [38] Acceleration of fibrinolysis with 40 kHz ultrasound.
    Suchkova, V
    Siddiqi, F
    Carstensen, E
    Dalecki, D
    Francis, C
    BLOOD, 1997, 90 (10) : 1324 - 1324
  • [39] 是1kHz还是100Hz~1kHz
    殷国政
    中学物理教学参考, 2007, (09) : 42 - 42
  • [40] MEASURING RECEIVER-CONVERTER FOR A FREQUENCY OF 66.(6) KHZ TO 100 KHZ
    LUKYANOV, VY
    MEASUREMENT TECHNIQUES, 1974, 17 (12) : 1914 - 1915