MOTION ARTIFACTS IN THE X-RAY CT IMAGE OF A REVOLVING POINT OBJECT

被引:1
|
作者
SAKAMOTO, T
SATO, S
机构
[1] Faculty of Engineering Science, Osaka University, Toyonaka
关键词
X-RAY CT; IMAGE RECONSTRUCTION; SCANNING TIME; MOTION ARTIFACT; CYCLOIDS;
D O I
10.1002/scj.4690251105
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
To obtain the cross section of an object by using an X-ray CT scanner, many projections of the object with various angles are required. This also takes time for scanning. If the object moves during this period, the projections would be disturbed causing motion artifact in the CT image. Understanding of their characteristics in relation to the movements of the objects will be useful for analyzing CT images and will supply new knowledge to medical diagnosis. This paper investigates a reconstructed image of a point object which revolves around the center of a scanning area. The results show that the reconstructed image of the point object forms an epicycloid or hypocycloid (a curve on a plane) and this reduces with time. The same type of artifact is simulated by a computer, and this justifies the analysis.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [41] CLASSIFICATION OF ARTIFACTS IN X-RAY CT IMAGES DUE TO NON-LINEAR SHADOWS
    DUERINCKX, AJ
    MACOVSKI, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2848 - 2852
  • [42] FBP initialization for transition artifacts reduction in statistical X-ray CT reconstruction.
    Zbijewski, W
    Beekman, FJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2970 - 2972
  • [43] X-ray CT metal artifacts reduction through curvature based sinogram inpainting
    Gu, Jianwei
    Zhang, Li
    Yu, Guoqiang
    Xing, Yuxiang
    Chen, Zhiqiang
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 73 - 82
  • [44] EFFECTIVE SINOGRAM-INPAINTING FOR METAL ARTIFACTS REDUCTION IN X-RAY CT IMAGES
    Kim, Youngshin
    Yoon, Seongbeak
    Yi, Juneho
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 597 - 600
  • [45] X-Ray to luminous image conversion in X-Ray image converter tubes
    Kuklev, SV
    Zaidel, IN
    23RD INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, PT 1, 1999, 3516 : 110 - 120
  • [46] X-ray of shipwreck could save artifacts
    Thilmany, J
    MECHANICAL ENGINEERING, 2002, 124 (05) : 16 - 16
  • [47] X-ray fluorescence imaging of ancient artifacts
    Thorne, Robert E.
    Geil, Ethan C.
    Hudson, Kathryn
    Clinton, Kevin
    Crowther, Charles
    Dale, Darren
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C762 - C762
  • [48] To Bronch Or Not To Bronch? Not The Chest X-Ray Artifacts
    Rojas-Gomez, J. C.
    Nystrom, P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [49] Artifacts in Qualititative and Quantitative X-Ray Mapping
    Wuhrer, Richard
    Moran, Ken
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 30 - 31
  • [50] CONCAVE AND REVOLVING MIRRORS OF THE X-RAY REGION .1.
    VINOGRADOV, AV
    KOVALEV, VF
    KOZHEVNIKOV, IV
    PUSTOVALOV, VV
    ZHURNAL TEKHNICHESKOI FIZIKI, 1985, 55 (02): : 244 - 250