MOTION ARTIFACTS IN THE X-RAY CT IMAGE OF A REVOLVING POINT OBJECT

被引:1
|
作者
SAKAMOTO, T
SATO, S
机构
[1] Faculty of Engineering Science, Osaka University, Toyonaka
关键词
X-RAY CT; IMAGE RECONSTRUCTION; SCANNING TIME; MOTION ARTIFACT; CYCLOIDS;
D O I
10.1002/scj.4690251105
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
To obtain the cross section of an object by using an X-ray CT scanner, many projections of the object with various angles are required. This also takes time for scanning. If the object moves during this period, the projections would be disturbed causing motion artifact in the CT image. Understanding of their characteristics in relation to the movements of the objects will be useful for analyzing CT images and will supply new knowledge to medical diagnosis. This paper investigates a reconstructed image of a point object which revolves around the center of a scanning area. The results show that the reconstructed image of the point object forms an epicycloid or hypocycloid (a curve on a plane) and this reduces with time. The same type of artifact is simulated by a computer, and this justifies the analysis.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] Analysis and correction of artifacts in X-ray industrial CT
    Zhang, QH
    Lu, HN
    Yang, M
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 4999 - 5003
  • [2] Adaptive processing to correct for organ motion artifacts in X-ray CT medical imaging systems
    Dhanantwari, AC
    Stergiopoulos, S
    SAM 2000: PROCEEDINGS OF THE 2000 IEEE SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP, 2000, : 261 - 265
  • [3] Object Separation in X-Ray Image Sets
    Heitz, Geremy
    Chechik, Gal
    2010 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2010, : 2093 - 2100
  • [4] Reduction of beam-hardening artifacts in X-ray CT
    Menvielle, Nathalie
    Goussard, Yves
    Orban, Dominique
    Soulez, Gilles
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1865 - 1868
  • [5] Artifacts in Spiral X-ray CT Scanners: Problems and Solutions
    Yazdi, Mehran
    Beaulieu, Luc
    PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 26, PARTS 1 AND 2, DECEMBER 2007, 2007, 26 : 376 - +
  • [6] Artifacts of X-ray CT data in the analysis of geomaterial properties
    Mukunoki, T
    Otani, J
    Obara, Y
    Kaneko, K
    X-RAY CT FOR GEOMATERIALS SOILS, CONCRETE, ROCKS, 2004, : 95 - 101
  • [7] Multidimensional registration of X-ray image and CT image
    Zhang, H
    Haigron, P
    Shu, HZ
    Luo, LM
    MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 : 717 - 724
  • [8] Projection registration of X-ray image and CT image
    Zhang, Hui
    Luo, Limin
    Shu, Huazhong
    Li, Songyi
    Haigron, Pascal
    Journal of Southeast University (English Edition), 2003, 19 (01) : 26 - 30
  • [9] Dual X-ray absorptiometry: Recognizing image artifacts and pathology
    Jacobson, JA
    Jamadar, DA
    Hayes, CW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (06) : 1699 - 1705
  • [10] Image degradation and stroboscopic images caused by rotary motion of the object in x-ray computer tomography
    Sakamoto, Takashi
    Sato, Shunsuke
    Systems and Computers in Japan, 1993, 24 (09) : 76 - 83