Image degradation and stroboscopic images caused by rotary motion of the object in x-ray computer tomography

被引:0
|
作者
Sakamoto, Takashi [1 ]
Sato, Shunsuke [1 ]
机构
[1] Osaka Univ, Toyonaka, Japan
关键词
Computer simulation - Image processing - Image quality - Image reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
This paper analyzes the degradation of reconstructed images and artifacts due to the rotary motion of a rigid object. The degradation of a CT image caused by rotation of an arbitrarily shaped rigid object is formulated by using a point-spread function. The characteristics of blurred images of a rigid object due to its rotation in a CT and the shape of blurred images also are analyzed. The cause of stroboscopic images is explained by using line sources. The theories have been confirmed by computer simulation.
引用
收藏
页码:76 / 83
相关论文
共 50 条
  • [1] X-RAY COMPUTER TOMOGRAPHY
    SOKOLOV, VN
    SUMAROKOV, AV
    TERNOVOY, SK
    TERAPEVTICHESKII ARKHIV, 1979, 51 (05) : 7 - &
  • [2] PRINCIPLES OF IMAGE-RECONSTRUCTION IN X-RAY COMPUTER TOMOGRAPHY
    SCHWIERZ, G
    HARER, W
    RUHRNSCHOPF, EP
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1978, 7 (04): : 196 - 203
  • [3] MOTION ARTIFACTS IN THE X-RAY CT IMAGE OF A REVOLVING POINT OBJECT
    SAKAMOTO, T
    SATO, S
    SYSTEMS AND COMPUTERS IN JAPAN, 1994, 25 (11) : 49 - 57
  • [4] X-ray phase tomography of a moving object
    Sung, Yongjin
    Gupta, Rajiv
    OPTICS EXPRESS, 2013, 21 (20): : 23671 - 23678
  • [5] Generative object separation in X-ray images
    Zheng, Xiaolong
    Zhou, Yu
    Yao, Jia
    Zheng, Liang
    JOURNAL OF ELECTRONIC IMAGING, 2024, 33 (05)
  • [6] Image Alignment for Tomography Reconstruction from Synchrotron X-Ray Microscopic Images
    Cheng, Chang-Chieh
    Chien, Chia-Chi
    Chen, Hsiang-Hsin
    Hwu, Yeukuang
    Ching, Yu-Tai
    PLOS ONE, 2014, 9 (01):
  • [7] IMAGE STATISTICS AND QUANTUM NOISE IN X-RAY COMPUTED-TOMOGRAPHY IMAGES
    DUERINCKX, AJ
    MACOVSKI, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 773 - 773
  • [8] Radiation Load in X-Ray Computer Tomography
    Blinov A.B.
    Blinov N.N.
    Biomedical Engineering, 2011, 44 (5) : 180 - 181
  • [9] X-Ray Refraction Computer-Tomography.
    Hentschel, MP
    Lange, A
    Müller, BR
    Schors, J
    Harbich, KW
    MATERIALPRUFUNG, 2000, 42 (06): : 217 - 221
  • [10] X-ray refraction computer-tomography
    Hentschel, Manfred P.
    Lange, Axel
    Müller, Bernd R.
    Schors, Jörg
    Harbich, Karl-Wolfram
    Materialpruefung/Materials Testing, 2000, 42 (06): : 217 - 221