HIGH-SPEED GC MS USING NARROW-BORE COLUMNS AND ION-TRAP DETECTION

被引:25
|
作者
VANYSACKER, PG [1 ]
JANSSEN, HGM [1 ]
SNIJDERS, HMJ [1 ]
LECLERCQ, PA [1 ]
CRAMERS, CA [1 ]
VANCRUCHTEN, HJM [1 ]
机构
[1] VARIAN NEDERLAND BV,3990 GB HOUTEN,NETHERLANDS
关键词
CAPILLARY GC; NARROW-BORE COLUMNS; GC MS; ION TRAP MASS SPECTROMETRY; DETECTION LIMITS; WORKING RANGE;
D O I
10.1002/mcs.1220050504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast gas chromatographic separations can be achieved by vacuum-outlet operation and by applying narrow-bore columns. In this work, the combination of 50 mum i.d. columns with ion trap mass spectrometric detection is evaluated. Detection limits in the electron ionization mode, and in the chemical ionization mode using CH4 as the reaction gas, are 1 pg and 5 pg, respectively. Owing to the high sensitivity of the ion trap mass spectrometer a significant improvement in the working range in comparison with other detection systems is obtained. The small column flows cause no loss of mass spectral resolution and sensitivity. The performance of the system is demonstrated by the analysis of some real-world samples.
引用
收藏
页码:413 / 419
页数:7
相关论文
共 50 条
  • [41] RAPID ANALYSIS OF ENVIRONMENTAL-SAMPLES USING SOLID-PHASE MICROEXTRACTION (SPME) AND NARROW-BORE CAPILLARY COLUMNS
    SHIREY, RE
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (08): : 495 - 499
  • [42] SAMPLE ENRICHMENT IN HIGH-SPEED NARROW BORE CAPILLARY GAS-CHROMATOGRAPHY
    VANES, A
    JANSSEN, J
    CRAMERS, C
    RIJKS, J
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (12): : 852 - 857
  • [43] Identification of anthocyanins in berries by narrow-bore high-performance liquid chromatography with electrospray ionization detection
    Dugo, P
    Mondello, L
    Errante, G
    Zappia, G
    Dugo, G
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (08) : 3987 - 3992
  • [44] Use of gas chromatography with ion-trap MS/MS detection for the determination of planar PCBs in biota and sediment
    Leonards, P.E.G.
    Brinkman, U.A.Th.
    Cofino, W.R.
    Chemosphere, 1996, 32 (12):
  • [45] The use of gas chromatography with ion-trap MS/MS detection for the determination of planar PCBs in biota and sediment
    Leonards, PEG
    Brinkman, UAT
    Cofino, WP
    CHEMOSPHERE, 1996, 32 (12) : 2381 - 2387
  • [46] Improved Single-Cell Proteome Coverage Using Narrow-Bore Packed NanoLC Columns and Ultrasensitive Mass Spectrometry
    Cong, Yongzheng
    Liang, Yiran
    Motamedchaboki, Khatereh
    Huguet, Romain
    Thy Truong
    Zhao, Rui
    Shen, Yufeng
    Lopez-Ferrer, Daniel
    Zhu, Ying
    Kelly, Ryan T.
    ANALYTICAL CHEMISTRY, 2020, 92 (03) : 2665 - 2671
  • [47] Simple and fast microderivatization method for determining formaldehyde using narrow-bore liquid chromatography with UV detection
    Ho, Hsin-Shu
    Lu, Chi-Yu
    ANALYTICAL METHODS, 2023, 15 (38) : 5095 - 5101
  • [48] Analysis of phenothrin and its metabolite 3-phenoxybenzoic acid (PBA) in agricultural products by GC and ion-trap GC/MS
    Hirahara, Y
    Tsumura, Y
    Nakamura, Y
    Tonogai, Y
    Shibata, T
    JOURNAL OF FOOD PROTECTION, 1997, 60 (03) : 305 - 308
  • [49] Problems and solutions in pesticide analysis using solid-phase extraction (SPE) and gas chromatography ion-trap mass spectrometry detection (GC-MS)
    Deger, AB
    Gremm, TJ
    Frimmel, FH
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 2000, 28 (06): : 292 - 299
  • [50] Tunable-column selectivity and time-of-flight detection for high-speed GC/MS
    Leonard, C
    Sacks, R
    ANALYTICAL CHEMISTRY, 1999, 71 (22) : 5177 - 5184