HIGH-SPEED GC MS USING NARROW-BORE COLUMNS AND ION-TRAP DETECTION

被引:25
|
作者
VANYSACKER, PG [1 ]
JANSSEN, HGM [1 ]
SNIJDERS, HMJ [1 ]
LECLERCQ, PA [1 ]
CRAMERS, CA [1 ]
VANCRUCHTEN, HJM [1 ]
机构
[1] VARIAN NEDERLAND BV,3990 GB HOUTEN,NETHERLANDS
关键词
CAPILLARY GC; NARROW-BORE COLUMNS; GC MS; ION TRAP MASS SPECTROMETRY; DETECTION LIMITS; WORKING RANGE;
D O I
10.1002/mcs.1220050504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast gas chromatographic separations can be achieved by vacuum-outlet operation and by applying narrow-bore columns. In this work, the combination of 50 mum i.d. columns with ion trap mass spectrometric detection is evaluated. Detection limits in the electron ionization mode, and in the chemical ionization mode using CH4 as the reaction gas, are 1 pg and 5 pg, respectively. Owing to the high sensitivity of the ion trap mass spectrometer a significant improvement in the working range in comparison with other detection systems is obtained. The small column flows cause no loss of mass spectral resolution and sensitivity. The performance of the system is demonstrated by the analysis of some real-world samples.
引用
收藏
页码:413 / 419
页数:7
相关论文
共 50 条
  • [11] ELECTRON-CAPTURE DETECTION IN HIGH-SPEED NARROW-BORE CAPILLARY GAS-CHROMATOGRAPHY - FAST AND SENSITIVE ANALYSIS OF PCBS AND PESTICIDES
    VANYSACKER, PG
    JANSSEN, HG
    SNIJDERS, HMJ
    CRAMERS, CA
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (07): : 397 - 402
  • [12] FAST ANALYSIS OF COMPLEX-MIXTURES USING NARROW-BORE OPEN TUBULAR COLUMNS
    GUIOCHON, G
    GONNORD, MF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 29 - ANYL
  • [13] High-speed GC-MS
    Leclercq, PA
    Cramers, CA
    MASS SPECTROMETRY REVIEWS, 1998, 17 (01) : 37 - 49
  • [14] Kinetic performance of narrow-bore columns on a micro-system for high performance liquid chromatography
    Gritti, Fabrice
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1236 : 105 - 114
  • [15] PEPTIDE-MAPPING BY REVERSED-PHASE HPLC USING NARROW-BORE AND MICROBORE COLUMNS
    HEROLD, M
    HEIGER, DN
    GRIMM, R
    AMERICAN LABORATORY, 1993, 25 (12) : J20 - &
  • [16] Rapid GC-MS analysis of methamphetamine and its metabolites in urine-application of a short narrow-bore capillary column to GC-MS
    Fujii, Hiroshi
    Hara, Kenji
    Kashimura, Seiichi
    Kageura, Mitsuyoshi
    Kashiwagi, Masayuki
    Miyoshi, Aya
    Ikeda, Sachiko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (02): : 116 - 120
  • [17] HIGH-SPEED NARROW-BORE CAPILLARY GAS-CHROMATOGRAPHY IN COMBINATION WITH A FAST DOUBLE-FOCUSING MASS-SPECTROMETER
    VANYSACKER, PG
    BROWN, J
    JANSSEN, HG
    LECLERCQ, PA
    PHILLIPS, A
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (09): : 517 - 524
  • [18] High-speed separation of arsenic compounds using narrow-bore high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry
    Wangkarn, S
    Pergantis, SA
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) : 627 - 633
  • [20] Identification of volatile compounds in sunflower oil by headspace SPME and ion-trap GC/MS
    Keszler, A
    Heberger, K
    Gude, M
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (06): : 368 - 370