[ASTERISK-C]OCTANOIC ACID BREATH TEST TO MEASURE GASTRIC-EMPTYING RATE OF SOLIDS

被引:49
|
作者
MAES, BD
GHOOS, YF
RUTGEERTS, PJ
HIELE, MI
GEYPENS, B
VANTRAPPEN, G
机构
[1] UNIV HOSP GASTHUISBERG,DEPT MED,DIV GASTROENTEROL,B-3000 LOUVAIN,BELGIUM
[2] UNIV HOSP GASTHUISBERG,GASTROINTESTINAL RES CTR,B-3000 LOUVAIN,BELGIUM
关键词
GASTRIC EMPTYING; SOLIDS; BREATH TEST; OCTANOIC ACID;
D O I
10.1007/BF02300385
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [C-14]octanoic acid or [C-13]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.
引用
收藏
页码:S104 / S106
页数:3
相关论文
共 50 条
  • [31] How accurate is the measurement of gastric emptying of solids by 13C-octanoic acid breath test in symptomatic diabetic patients?
    Lee, JS
    Choi, MG
    Burton, DD
    Nair, KS
    Verlinden, M
    Olson, CA
    Camilleri, M
    GASTROENTEROLOGY, 1998, 114 (04) : A786 - A786
  • [32] Measuring Gastric Emptying: Comparison of 13C-Octanoic Acid Breath Test and Scintigraphy
    Jari Punkkinen
    Ilmari Konkka
    Olli Punkkinen
    Tapani Korppi-Tommola
    Martti Färkkilä
    Jari Koskenpato
    Digestive Diseases and Sciences, 2006, 51 : 262 - 267
  • [33] DELAYED GASTRIC EMPTYING USING 13C OCTANOIC ACID BREATH TEST IN SSc
    Marie, I.
    Gourcerol, G.
    Leroi, A. M.
    Menard, J. F.
    Ducrotte, P.
    RHEUMATOLOGY, 2012, 51 : 7 - 7
  • [34] Comparison of 13c-octanoic acid breath test and scintigraphy for measuring gastric emptying
    Punkkinen, JM
    Koskenpato, J
    Farkkila, M
    Kairamo, K
    Konkka, I
    GASTROENTEROLOGY, 2003, 124 (04) : A674 - A674
  • [35] GASTRIC EMPTYING IN ANOREXIC ADOLESCENTS MEASURED WITH THE 13C OCTANOIC ACID BREATH TEST
    Docx, M. K. F.
    Simons, A.
    Staelens, S.
    Verbeke, K.
    Ramet, J.
    Veereman-Wauters, G.
    PEDIATRIC RESEARCH, 2010, 68 : 162 - 162
  • [36] Measuring gastric emptying:: Comparison of 13C-octanoic acid breath test and scintigraphy
    Punkkinen, J
    Konkka, I
    Punkkinen, O
    Korppi-Tommola, T
    Färkkilä, M
    Koskenpato, J
    DIGESTIVE DISEASES AND SCIENCES, 2006, 51 (02) : 262 - 267
  • [37] Measuring gastric emptying with the 13C octanoic acid breath test in infants and children
    Veereman-Wauters, G
    GUT, 1998, 43 : S29 - S30
  • [38] 13C-octanoic acid breath test:: a reliable tool for measuring gastric emptying
    Perri, F
    Clemente, R
    Festa, V
    Quitadamo, M
    Niro, G
    Andriulli, A
    ITALIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1998, 30 (02): : 211 - 217
  • [39] Assessment of gastric emptying in the mouse using the [13C]-octanoic acid breath test
    Symonds, EL
    Butler, RN
    Omari, TI
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2000, 27 (09) : 671 - 675
  • [40] 13C-octanoic acid breath test (OBT) with a new test meal (EXPIROGer®): Toward standardization for testing gastric emptying of solids
    Perri, Francesco
    Bellini, Massimo
    Portincasa, Piero
    Parodi, Andrea
    Bonazzi, Patrizia
    Marzio, Leonardo
    Galeazzi, Francesca
    Usai, Paolo
    Citrino, Attilio
    Usai-Satta, Paolo
    DIGESTIVE AND LIVER DISEASE, 2010, 42 (08) : 549 - 553