LOW-ENERGY ENDOCARDIAL CARDIOVERSION OF ATRIAL ARRHYTHMIAS IN HUMANS

被引:19
|
作者
KALMAN, JM [1 ]
JONES, EF [1 ]
DOOLAN, L [1 ]
OLIVER, LE [1 ]
POWER, JM [1 ]
TONKIN, AM [1 ]
机构
[1] AUSTIN HOSP,DEPT CARDIOL,HEIDELBERG,VIC 3084,AUSTRALIA
来源
关键词
ATRIAL FIBRILLATION; ATRIAL FLUTTER; ENDOCARDIAL DEFIBRILLATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;
D O I
10.1111/j.1540-8159.1995.tb03834.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We assessed the feasibility of low energy endocardial defibrillation in patients with atrial fibrillation or atrial flutter who had failed a trial of pharmacological reversion with amiodarone. Low energy endocardial defibrillation under general anesthesia was attempted in 9 patients, 5 with atrial flutter and 4 with atrial fibrillation (median duration of arrhythmia 3.75 months). Two large surface area endocardial leads were introduced percutaneously and sited in the right atrial appendage and at the right ventricular apex. A cutaneous patch electrode was placed on the left thorax. Biphasic shocks synchronized to the ventricular electrogram were used to terminate atrial arrhythmias. Three electrode configurations were evaluated in the following sequence at each energy level: atrial cathode to ventricular anode; ventricular cathode to atrial anode; atrial cathode to a combined ventricular and cutaneous anode. If endocardial defibrillation failed (0.5-10 J), transthoracic defibrillation using 200 joules followed by 360 joules, if required, was performed. Endocardial defibrillation was successful in all five patients with atrial flutter (0.5 J, 1.0 J, 1.0 J, 4.0 J, and 10.0 J) but in only one patient with atrial fibrillation (10 J). On no occasion did successful defibrillation occur with one configuration when it had failed with an alternate configuration at that particular energy level. Ventricular fibrillation did not occur, and there were no other significant complications. Low energy endocardial defibrillation is feasible in patients with atrial flutter using large surface area electrodes. Although the success rate of atrial defibrillation was low, further work is required, particularly in patients with more recent onset of the arrhythmia and using a right to left electrode configuration.
引用
收藏
页码:1869 / 1875
页数:7
相关论文
共 50 条
  • [31] A novel electrode placement strategy for low-energy internal cardioversion of atrial fibrillation: A simulation study
    Yang, Fei
    Sha, Qun
    Patterson, Robert P.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 158 (01) : 149 - 152
  • [32] Transoesophageal low-energy cardioversion of atrial fibrillation performed without fluoroscopy outside the EP lab
    Santini, M
    Pandozi, C
    Castro, A
    Lamberti, F
    Calo', L
    Canale, G
    Ricci, R
    Loricchio, ML
    EUROPEAN HEART JOURNAL, 2000, 21 : 560 - 560
  • [33] Internal low-energy cardioversion:: A therapeutic option for restoring sinus rhythm in chronic atrial fibrillation after failure of external cardioversion
    Taramasco, V
    Socas, A
    Ricard, P
    Lévy, S
    EUROPACE, 1999, 1 (03): : 179 - 182
  • [34] Low-energy internal cardioversion of atrial fibrillation after failed external cardioversion - Texas Heart Institute experience and review of the literature
    Zaqqa, M
    Afshar, H
    Khoshnevis, GR
    Lopez, JA
    Massumi, A
    TEXAS HEART INSTITUTE JOURNAL, 1999, 26 (02) : 114 - 119
  • [35] Embolic complications of direct current cardioversion of atrial arrhythmias: Association with low intensity of anticoagulation at the time of cardioversion
    Gallagher, MM
    Hennessy, BJ
    Edvardsson, N
    Hart, CM
    Shannon, MS
    Obel, OA
    Al-Saady, NM
    Camm, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (05) : 926 - 933
  • [36] TRANSVENOUS LOW-ENERGY CARDIOVERSION FOR THE TREATMENT OF VENTRICULAR TACHYCARDIAS
    FROHNER, K
    KALTENBRUNNER, W
    PODCZECK, A
    STEINBACH, K
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A39 - A39
  • [37] Prospective randomized trial of transthoracic versus low-energy transvenous internal cardioversion in persistent atrial fibrillation
    Yalçin, R
    Kaya, MG
    Ozdemir, M
    Cemri, M
    Timurkaynak, T
    Boyaci, B
    Çengel, A
    ACTA CARDIOLOGICA, 2004, 59 (05) : 521 - 526
  • [38] Successful cardioversion of chronic atrial fibrillation using standard electrophysiology catheters and low-energy biphasic shocks
    Adler, SW
    Nelson, LK
    Spevack, RP
    Vatterott, PJ
    Dunbar, DN
    Granrud, GA
    CIRCULATION, 1998, 98 (17) : 103 - 103
  • [39] Internal cardioversion with low energy shocks of atrial fibrillation resistant to external cardioversion
    García, JG
    Almendral, J
    Arenal, A
    Villacastín, J
    Osende, J
    Sande, JLM
    Ortiz, M
    Delcán, JL
    REVISTA ESPANOLA DE CARDIOLOGIA, 1999, 52 (02): : 105 - 112
  • [40] Low energy transvenous cardioversion of short duration atrial tachyarrhythmias in humans using a single lead system
    Heisel, A
    Jung, J
    Fries, R
    Stopp, M
    Sen, S
    Schieffer, H
    Ozbek, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01): : 65 - 71