LOW-ENERGY ENDOCARDIAL CARDIOVERSION OF ATRIAL ARRHYTHMIAS IN HUMANS

被引:19
|
作者
KALMAN, JM [1 ]
JONES, EF [1 ]
DOOLAN, L [1 ]
OLIVER, LE [1 ]
POWER, JM [1 ]
TONKIN, AM [1 ]
机构
[1] AUSTIN HOSP,DEPT CARDIOL,HEIDELBERG,VIC 3084,AUSTRALIA
来源
关键词
ATRIAL FIBRILLATION; ATRIAL FLUTTER; ENDOCARDIAL DEFIBRILLATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;
D O I
10.1111/j.1540-8159.1995.tb03834.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We assessed the feasibility of low energy endocardial defibrillation in patients with atrial fibrillation or atrial flutter who had failed a trial of pharmacological reversion with amiodarone. Low energy endocardial defibrillation under general anesthesia was attempted in 9 patients, 5 with atrial flutter and 4 with atrial fibrillation (median duration of arrhythmia 3.75 months). Two large surface area endocardial leads were introduced percutaneously and sited in the right atrial appendage and at the right ventricular apex. A cutaneous patch electrode was placed on the left thorax. Biphasic shocks synchronized to the ventricular electrogram were used to terminate atrial arrhythmias. Three electrode configurations were evaluated in the following sequence at each energy level: atrial cathode to ventricular anode; ventricular cathode to atrial anode; atrial cathode to a combined ventricular and cutaneous anode. If endocardial defibrillation failed (0.5-10 J), transthoracic defibrillation using 200 joules followed by 360 joules, if required, was performed. Endocardial defibrillation was successful in all five patients with atrial flutter (0.5 J, 1.0 J, 1.0 J, 4.0 J, and 10.0 J) but in only one patient with atrial fibrillation (10 J). On no occasion did successful defibrillation occur with one configuration when it had failed with an alternate configuration at that particular energy level. Ventricular fibrillation did not occur, and there were no other significant complications. Low energy endocardial defibrillation is feasible in patients with atrial flutter using large surface area electrodes. Although the success rate of atrial defibrillation was low, further work is required, particularly in patients with more recent onset of the arrhythmia and using a right to left electrode configuration.
引用
收藏
页码:1869 / 1875
页数:7
相关论文
共 50 条
  • [21] LOW ENERGY CARDIOVERSION FOR ATRIAL FLUTTER
    Obi, V. O.
    Isber, N.
    Bloomfield, D.
    Arulthasan, M.
    CARDIOLOGY, 2016, 134 : 356 - 356
  • [22] Transoesophageal low-energy cardioversion of atrial fibrillation - Results with the oesophageal-right atrial lead configuration
    Santini, M
    Pandozi, C
    Colivicchi, F
    Ammirati, F
    Scianaro, MC
    Castro, A
    Lamberti, F
    Gentilucci, G
    EUROPEAN HEART JOURNAL, 2000, 21 (10) : 848 - 855
  • [23] Efficacy and tolerability in fully conscious patients of transvenous low-energy internal atrial cardioversion for atrial fibrillation
    Boriani, G
    Biffi, M
    Bronzetti, G
    Ayers, GM
    Zannoli, R
    Branzi, A
    Capucci, A
    Magnani, B
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (02): : 241 - 244
  • [24] Low-energy cardioversion of spontaneous atrial fibrillation - Immediate and long-term results
    Levy, S
    Ricard, P
    Gueunoun, M
    Yapo, F
    Trigano, J
    Mansouri, C
    Paganelli, F
    CIRCULATION, 1997, 96 (01) : 253 - 259
  • [25] Low-energy cardioversion versus medical treatment for the termination of atrial fibrillation after CABG
    Bechtel, JFM
    Christiansen, JF
    Sievers, HH
    Bartels, C
    ANNALS OF THORACIC SURGERY, 2003, 75 (04): : 1185 - 1188
  • [26] TRANSVENOUS LOW-ENERGY CARDIOVERSION IN VENTRICULAR TACHYCARDIAS
    FROHNER, K
    KALTENBRUNNER, W
    PODCZECK, A
    STEINBACH, K
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 97 - 97
  • [27] Effectiveness and safety of low-energy internal cardioversion of long-standing atrial fibrillation after unsuccessful external cardioversion
    Sharp, JC
    Whalley, DW
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (06): : 657 - +
  • [28] The Role of Endocardial Trabeculations in Low-Energy Defibrillation
    Connolly, Adam
    Bishop, Martin J.
    FUNCTIONAL IMAGING AND MODELING OF THE HEART (FIMH 2015), 2015, 9126 : 412 - 420
  • [29] Low energy intracardiac cardioversion of atrial fibrillation
    Kulbertus, HE
    EUROPEAN HEART JOURNAL, 1997, 18 (11) : 1693 - 1695
  • [30] Low energy electrical cardioversion of atrial fibrillation
    Stanaitiene, Giedre
    CARDIOLOGY, 2009, 113 : 67 - 67