DEVELOPMENT OF A NEW INTRAOPERATIVE RADIOFREQUENCY ABLATION TECHNIQUE USING A NEEDLE ELECTRODE

被引:13
|
作者
OHTAKE, H [1 ]
MISAKI, T [1 ]
MATSUNAGA, Y [1 ]
WATANABE, G [1 ]
TAKAHASHI, M [1 ]
MATSUMOTO, I [1 ]
KAWASUJI, M [1 ]
WATANABE, Y [1 ]
机构
[1] TOYAMA MED & PHARMACEUT UNIV,DEPT SURG 1,TOYAMA,JAPAN
来源
ANNALS OF THORACIC SURGERY | 1994年 / 58卷 / 03期
关键词
D O I
10.1016/0003-4975(94)90740-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We studied a new intraoperative technique for radiofrequency ablation using a needle electrode. The ventricles of 12 mongrel dogs were ablated. The needle electrode was inserted to a depth of 3 mm through the epicardium. Macroscopically, tissue defect was found only at the needle insertion site. The degenerated area had a well-demarcated bullet shape with microscopical coagulation necrosis. This characteristic shape allows the ablation of deeper areas of the myocardium by deeper insertion of the ablation needle. Compared with conventional epicardial surface ablation, this new method could be used to achieve deeper coagulation. For any given energy level and conductance, the ratio between the volume and the depth of the lesion with this new method is smaller than that of lesions made by the conventional radiofrequency ablation method. With this new method, the energy spreads vertically, a characteristic suitable for deep ablation. This may result from the shape of the needle electrode itself. For ablation of deep targets, this new method is superior to the conventional approach because less myocardium is coagulated and the target can be ablated with greater efficiency, requiring the destruction of less tissue. In conclusion, the needle electrode procedure can achieve a narrower ablation for deeper targets than can the conventional technique.
引用
收藏
页码:750 / 753
页数:4
相关论文
共 50 条
  • [41] Intraoperative radiofrequency ablation or cryoablation for hepatic malignancies
    Pearson, AS
    Izzo, F
    Fleming, RYD
    Ellis, LM
    Delrio, P
    Roh, MS
    Granchi, J
    Curley, SA
    AMERICAN JOURNAL OF SURGERY, 1999, 178 (06): : 592 - 598
  • [42] Optimization of an Endoscopic Radiofrequency Ablation Electrode
    Hanks, Bradley
    Frecker, Mary
    Moyer, Matthew
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2018, 12 (03):
  • [43] A tubular electrode for radiofrequency ablation therapy
    Antunes, Carlos L.
    Almeida, Tony R.
    Raposeiro, Nélia
    Gonçalves, Belarmino
    Almeida, Paulo
    Antunes, André
    World Academy of Science, Engineering and Technology, 2010, 46 : 516 - 522
  • [44] Complications of intraoperative radiofrequency ablation of liver metastases
    Razafindratsira, Tsiriniaina
    Isambert, Milene
    Evrard, Serge
    HPB, 2011, 13 (01) : 15 - 23
  • [45] Radiofrequency ablation electrode displacement elastography
    Bharat, S.
    Zagzebski, J.
    Madsen, E.
    Varghese, T.
    MEDICAL PHYSICS, 2006, 33 (06) : 2230 - 2230
  • [46] NEEDLE ELECTRODE CONNECTORS FOR EMG TESTING - A NEW TECHNIQUE
    GARRETT, VE
    SCOTT, JA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1986, 67 (09): : 604 - 605
  • [47] Radiofrequency ablation (coblation): a promising new technique for laryngeal papillomata
    Timms, M. S.
    Bruce, I. A.
    Patel, N. K.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2007, 121 (01): : 28 - 30
  • [48] Evaluation of ablated area of percutaneous radiofrequency ablation, using Leveen needle electrode, of small hepatocellular carcinoma with CT imaging.
    Kira, S
    Date, S
    Yamashita, Y
    Kawakami, T
    Sumii, K
    Sumida, Y
    HEPATOLOGY, 2003, 38 (04) : 768A - 769A
  • [49] Bipolar Radiofrequency Ablation: Development of a New Expandable Device
    Ito, Nobutake
    Pfeffer, Jochen
    Isfort, Peter
    Penzkofer, Tobias
    Kuhl, Christiane K.
    Mahnken, Andreas H.
    Schmitz-Rode, Thomas
    Bruners, Philipp
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (03) : 770 - 776
  • [50] Bipolar Radiofrequency Ablation: Development of a New Expandable Device
    Nobutake Ito
    Jochen Pfeffer
    Peter Isfort
    Tobias Penzkofer
    Christiane K. Kuhl
    Andreas H. Mahnken
    Thomas Schmitz-Rode
    Philipp Bruners