Diagnostic Accuracy of Magnetic Resonance Imaging for Localizing Testes in Cases of Cryptorchidism

被引:0
|
作者
Ahmad, Smeera [1 ]
Sultan, Nadia [1 ]
Ameer, Ashfa [1 ]
机构
[1] Childrens Hosp & Inst Child Hlth, Dept Diagnost Radiol, Lahore, Pakistan
来源
关键词
MRI imaging; Localizing of testes; Diagnostic accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To determine the diagnostic accuracy of MRI for localizing undescended testes in clinically detected cases of cryptorchidism taking surgical findings as gold standard. Study design: Cross-sectional survey Methods: It was a cross-sectional survey. Patients were recruited by non probability purposive sampling technique. One hundred and seventy clinically and ultrasonically (superficial linear 7.5 MHZ transducer with AU5 Harmonic EZAOTI) diagnosed cases of non palpable undescended testes having age ranged between 0-16 years were selected from the Department of Diagnostic Radiology, The Children's Hospital and Institute of Child Health, Lahore during the period of six months from 03-08-2007 to 02-08-2009. Children having ambiguous genitalia on clinical examination and Boys not fit for anesthesia or surgery were excluded from study. MRI of all cases using 1.5 Tesla MR System was performed. Results: The age of the patients ranged between 0-16 years. Mean age of the patients was 5.1 +/- 2.3 years. According to the side affected, there were 49 cases (28.8%) on right side, 93 cases (54.7%) on left side and 28 cases (16.5%) bilateral. Comparison of the results of MRI with surgical findings showed that there were 127 true positive cases, 3 false positive cases, 27 false negative cases and 13 true negative cases. Statistical analysis of the study revealed sensitivity 82.4%, specificity 81.2%, diagnostic accuracy 82.3%, positive predictive value 97.6%, and negative predictive value 32.5% of MRI for localizing undescended testes in clinically detected cases of cryptorchidism taking surgical findings as gold standard. Conclusion: It is concluded that magnetic resonance imaging (MRI) offered a new promising imaging modality for localization of the undescended testis because it has better resolution, multiplanar capability, different sequences and is also non-hazardous and safe.
引用
收藏
页码:1164 / U396
页数:3
相关论文
共 50 条
  • [1] A Study to Determine the Magnetic Resonance Imaging Diagnostic Accuracy for Localizing Testis in Cryptorchidism Cases
    Yadullah
    Arshad, Junaid
    Ullah, Sami
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2019, 8 (11): : 124 - 128
  • [2] Diagnostic Accuracy of Ultrasonography for Diagnosis of Undescended Testes in pediatric population using Magnetic Resonance Imaging as gold standard
    Amjad, Muhammad Sohaib
    Yousuf, Khalid Rehman
    Bhatti, Shahzad Karim
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (01): : 306 - 308
  • [3] Hip pathology: the diagnostic accuracy of magnetic resonance imaging
    Annabell, Lucas
    Master, Vahid
    Rhodes, Alexander
    Moreira, Brett
    Coetzee, Cassandra
    Phong Tran
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [4] Hip pathology: the diagnostic accuracy of magnetic resonance imaging
    Lucas Annabell
    Vahid Master
    Alexander Rhodes
    Brett Moreira
    Cassandra Coetzee
    Phong Tran
    Journal of Orthopaedic Surgery and Research, 13
  • [5] Diagnostic Accuracy of Magnetic Resonance Imaging in Endometrial Cancer
    McComiskey, Mark H.
    McCluggage, W. Glenn
    Grey, Arthur
    Harley, Ian
    Dobbs, Stephen
    Nagar, Hans A.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2012, 22 (06) : 1020 - 1025
  • [6] What Is the Diagnostic Accuracy of Magnetic Resonance Imaging for Acute Appendicitis?
    April, Michael D.
    Long, Brit
    ANNALS OF EMERGENCY MEDICINE, 2018, 72 (03) : 308 - 309
  • [7] MAGNETIC-RESONANCE-IMAGING OF UNDESCENDED TESTES
    LANDA, HM
    GYLYSMORIN, V
    HAJEK, PC
    MUSMANNO, M
    MATTREY, RF
    PACKER, MG
    JOURNAL OF UROLOGY, 1987, 137 (04): : A302 - A302
  • [8] Diagnostic accuracy of synovial chondromatosis of the temporomandibular joint on magnetic resonance imaging
    Liu, Xiaohan
    Wan, Shaonan
    Shen, Pei
    Qiu, Yating
    Sah, Manoj Kumar
    Abdelrehem, Ahmed
    Chen, Minjie
    Zhang, Shanyong
    Yang, Chi
    PLOS ONE, 2019, 14 (01):
  • [9] Diagnostic Accuracy on Magnetic Resonance Imaging for the Diagnosis of Osteoarthritis of the Temporomandibular Joint
    Yura, Shinya
    Harada, Saori
    Kobayashi, Kazuhiko
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (07) : ZC98 - ZC101
  • [10] Diagnostic and staging accuracy of magnetic resonance imaging for the assessment of sinonasal disease
    Lin, Harrison W.
    Bhattacharyya, Neil
    AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2009, 23 (01) : 36 - 39