Diagnostic Accuracy of Magnetic Resonance Imaging for Localizing Testes in Cases of Cryptorchidism

被引:0
|
作者
Ahmad, Smeera [1 ]
Sultan, Nadia [1 ]
Ameer, Ashfa [1 ]
机构
[1] Childrens Hosp & Inst Child Hlth, Dept Diagnost Radiol, Lahore, Pakistan
来源
关键词
MRI imaging; Localizing of testes; Diagnostic accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To determine the diagnostic accuracy of MRI for localizing undescended testes in clinically detected cases of cryptorchidism taking surgical findings as gold standard. Study design: Cross-sectional survey Methods: It was a cross-sectional survey. Patients were recruited by non probability purposive sampling technique. One hundred and seventy clinically and ultrasonically (superficial linear 7.5 MHZ transducer with AU5 Harmonic EZAOTI) diagnosed cases of non palpable undescended testes having age ranged between 0-16 years were selected from the Department of Diagnostic Radiology, The Children's Hospital and Institute of Child Health, Lahore during the period of six months from 03-08-2007 to 02-08-2009. Children having ambiguous genitalia on clinical examination and Boys not fit for anesthesia or surgery were excluded from study. MRI of all cases using 1.5 Tesla MR System was performed. Results: The age of the patients ranged between 0-16 years. Mean age of the patients was 5.1 +/- 2.3 years. According to the side affected, there were 49 cases (28.8%) on right side, 93 cases (54.7%) on left side and 28 cases (16.5%) bilateral. Comparison of the results of MRI with surgical findings showed that there were 127 true positive cases, 3 false positive cases, 27 false negative cases and 13 true negative cases. Statistical analysis of the study revealed sensitivity 82.4%, specificity 81.2%, diagnostic accuracy 82.3%, positive predictive value 97.6%, and negative predictive value 32.5% of MRI for localizing undescended testes in clinically detected cases of cryptorchidism taking surgical findings as gold standard. Conclusion: It is concluded that magnetic resonance imaging (MRI) offered a new promising imaging modality for localization of the undescended testis because it has better resolution, multiplanar capability, different sequences and is also non-hazardous and safe.
引用
收藏
页码:1164 / U396
页数:3
相关论文
共 50 条
  • [21] Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy
    Theodoropoulos, John S.
    Andreisek, Gustav
    Harvey, Edward J.
    Wolin, Preston
    SKELETAL RADIOLOGY, 2010, 39 (07) : 661 - 667
  • [22] Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy
    John S. Theodoropoulos
    Gustav Andreisek
    Edward J. Harvey
    Preston Wolin
    Skeletal Radiology, 2010, 39 : 661 - 667
  • [23] The "Crossing Collection Sign": A Diagnostic Tool on Spine Magnetic Resonance Imaging For Localizing Cerebrospinal Fluid Leak
    Hill, Daniel
    Buchbinder, Bradley
    Pomerantz, Stuart
    Mehan, William A.
    Buch, Karen
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 337 - 342
  • [24] Magnetic resonance imaging for paediatric retroperitoneal masses: Diagnostic accuracy of the claw sign
    Combrink, Lisa
    Beviss-Challinor, Kenneth B.
    SA JOURNAL OF RADIOLOGY, 2021, 25 (01):
  • [25] Diagnostic Accuracy of Magnetic Resonance Imaging versus Clinical Staging in Cervical Cancer
    Shirazi, Ahmad Soltani
    Razi, Taghi
    Cheraghi, Fatemeh
    Rahim, Fakher
    Ehsani, Sara
    Davoodi, Mohammad
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (14) : 5729 - 5732
  • [26] Diagnostic Accuracy of an iPhone DICOM Viewer for the Interpretation of Magnetic Resonance Imaging of the Knee
    De Maio, Peter
    White, Lawrence M.
    Bleakney, Robert
    Menezes, Ravi J.
    Theodoropoulos, John
    CLINICAL JOURNAL OF SPORT MEDICINE, 2014, 24 (04): : 308 - 314
  • [27] Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging for Differentiation Between Parotid Neoplasms
    Elmokadem, Ali H.
    Khalek, Ahmed M. Abdel
    Wahab, Rihame M. Abdel
    Tharwat, Nehal
    Gaballa, Ghada M.
    Elata, Mohamed Abo
    Amer, Talal
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2019, 70 (03): : 264 - 272
  • [28] Diagnostic accuracy of laparoscopy, magnetic resonance imaging, and histopathologic examination for the detection of endometriosis
    Stratton, P
    Winkel, C
    Premkumar, A
    Chow, C
    Wilson, J
    Hearns-Stokes, R
    Heo, S
    Merino, M
    Nieman, LK
    FERTILITY AND STERILITY, 2003, 79 (05) : 1078 - 1085
  • [29] Diagnostic Accuracy of Magnetic Resonance Imaging for the Evaluation of Acute Female Pelvic Pathology
    Repplinger, M. D.
    Bracken, R. L.
    Chiu, A. H.
    Markhardt, B.
    Lubner, M. G.
    Ziemlewicz, T. J.
    Pickhardt, P. J.
    Harringa, J. B.
    Reeder, S. B.
    ANNALS OF EMERGENCY MEDICINE, 2018, 72 (04) : S59 - S59
  • [30] The diagnostic accuracy of magnetic resonance imaging in detecting cervical involvement in endometrial cancer
    Nagar, Hans
    Dobbs, Stephen
    McClelland, H. Raymond
    Price, John
    McCluggage, W. Glenn
    Grey, Arthur
    GYNECOLOGIC ONCOLOGY, 2006, 103 (02) : 431 - 434