Diagnostic Accuracy of Ultrasonography for Diagnosis of Undescended Testes in pediatric population using Magnetic Resonance Imaging as gold standard

被引:0
|
作者
Amjad, Muhammad Sohaib [1 ]
Yousuf, Khalid Rehman
Bhatti, Shahzad Karim
机构
[1] Sir Ganga Ram Hosp, Radiol Dept, Lahore, Pakistan
来源
关键词
Undescended testes; cryptorchidism; ultrasound; magnetic resonance imaging; male children;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Undescended testes or cryptorchidism is a developmental condition of abnormal location of testes and they are not normally located in the scrotal sac. It can be unilateral or bilateral. Accurate diagnosis is necessary for healthy fruitful life of male children in future. Ultrasound is being considered the useful imaging tool for the localization of palpable testes. But controversy was noted. Aim: To ascertain the diagnostic accuracy of Ultrasonography for diagnosis of undescended testes in pediatric population using MRI as gold standard Study Design: Cross sectional study. Setting: Department of Diagnostic and Interventional Radiology, Sir Ganga Ram Hospital, Lahore. Duration of Study: 6 months from 09-07-2017 to 10-01-2018 Methods: 130 cases fulfilled inclusion criteria were registered in the study. Patients underwent ultrasonography and later on MRI scan for confirmation of presence of undescended testes. The findings were collected on proforma. Data was entered and evaluated through Statistical Package for Social Sciences (SPSS). Sensitivity, specificity, PPV, NPV and diagnostic accuracy of ultrasound was calculated taking MRI scan as gold standard. Results: The mean age of children was 8.64 +/- 4.08years. The mean weight of children was 30.40 +/- 13.81kg. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of ultrasound were 90.2%, 94.9%, 92%, 93.8% and 93.1% respectively, taking MRI as gold standard. Conclusion: Thus, ultrasound is accurate enough to detect undescended testes. So in future, we can replace MRI with ultrasound for detection of undescended testes and prevent children from hazardous rays of MRI.
引用
收藏
页码:306 / 308
页数:3
相关论文
共 50 条
  • [1] MAGNETIC-RESONANCE-IMAGING OF UNDESCENDED TESTES
    LANDA, HM
    GYLYSMORIN, V
    HAJEK, PC
    MUSMANNO, M
    MATTREY, RF
    PACKER, MG
    JOURNAL OF UROLOGY, 1987, 137 (04): : A302 - A302
  • [2] Accuracy of High Resolution Ultrasonography for Diagnosis of Rotator Cuff Tears Considering Magnetic Resonance Imaging as Gold Standard
    Nadeem, Rana Dilawaiz
    Yousaf, Khalid Rehman
    Yusuf, Muhammad Tahir
    Akhtar, Muhammad
    Naqshband, Mumraiz S.
    Ahmed, Irfan
    Nadeem, Muhammad Jazib
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2021, 27 (02): : 234 - 238
  • [3] Diagnostic Accuracy of Magnetic Resonance Imaging for Localizing Testes in Cases of Cryptorchidism
    Ahmad, Smeera
    Sultan, Nadia
    Ameer, Ashfa
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2013, 7 (04): : 1164 - U396
  • [4] THE ROLE OF MAGNETIC-RESONANCE-IMAGING IN THE INVESTIGATION OF UNDESCENDED TESTES
    TROUGHTON, AH
    WARING, J
    LONGSTAFF, A
    GODDARD, PR
    CLINICAL RADIOLOGY, 1990, 41 (03) : 178 - 181
  • [5] MAGNETIC-RESONANCE-IMAGING IN THE LOCALIZATION OF UNDESCENDED ABDOMINAL TESTES
    ZOBEL, BB
    VICENTINI, C
    MASCIOCCHI, C
    GALLUCCI, M
    TUBARO, A
    MIANO, L
    PASSARIELLO, R
    EUROPEAN UROLOGY, 1990, 17 (02) : 145 - 148
  • [6] Diagnostic accuracy of endoscopic ultrasonography in patients with inconclusive magnetic resonance imaging diagnosis of biliopancreatic abnormalities
    Sotoudehmanesh R.
    Khatibian M.
    Ghadir M.-R.
    Bagheri M.
    Hashemi-Taheri A.P.
    Sedighi N.
    Ali-Asgari A.
    Zeinali F.
    Shahraeeni S.
    Kolahdoozan S.
    Indian Journal of Gastroenterology, 2011, 30 (4) : 156 - 160
  • [7] Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta
    Palacios Jaraquemada, Jose Miguel
    Bruno, Claudio Hernan
    OBSTETRICS AND GYNECOLOGY, 2007, 109 (01): : 203 - 203
  • [8] Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta
    Riteau, Anne-Sophie
    Tassin, Mikael
    Chambon, Guillemette
    Le Vaillant, Claudine
    de Laveaucoupet, Jocelyne
    Quere, Marie-Pierre
    Joubert, Madeleine
    Prevot, Sophie
    Philippe, Henri-Jean
    Benachi, Alexandra
    PLOS ONE, 2014, 9 (04):
  • [9] Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta
    Warshak, Carri R.
    Eskander, Ramez
    Hull, Andrew D.
    Scioscia, Angela L.
    Mattrey, Robert F.
    Benirschke, Kurt
    Resnik, Robert
    OBSTETRICS AND GYNECOLOGY, 2006, 108 (03): : 573 - 581
  • [10] Diagnostic Accuracy of Magnetic Resonance Imaging in Perianal Fistula Taking Surgical Findings as Gold Standard
    Ishfaq, Saher
    Qamar, Muhammad Adeel
    Zaman, Mehreen
    Makki, Mujeeb Ullah
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (03): : 939 - 941