Experimental investigation and optimisation study of a direct thermosyphon heat-pipe evacuated tube solar water heater subjected to a northern maritime climate

被引:9
|
作者
Redpath, D. A. G. [1 ]
Lo, S. N. G. [2 ]
Eames, P. C. [3 ]
机构
[1] Univ Ulster, Ctr Sustainable Technol, Jordanstown BT37 OQB, Antrim, North Ireland
[2] Univ Bath, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England
[3] Univ Loughborough, Ctr Renewable Energy Syst Technol, Dept Elect & Elect Engn, Loughborough LE11 3TU, Leics, England
关键词
D O I
10.1080/01430750.2010.9675106
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A proprietary heat-pipe Evacuated Tube Solar Water Heater (ETSWH) originally designed for collection of solar energy using forced fluid circulation was operated using thermosyphon fluid circulation. The thermal performance of this solar water heating system was monitored from October 2006 to June 2007. The ETSWH array was inclined with the expected collector outlet at a higher datum level than the expected collector inlet to provide a hydrostatic pressure differential across the manifold. During the monitoring period it was observed that thermosyphon flow was not always in the expected direction, with flow reversal occurring when the collector inlet temperature was greater than that of the outlet. When the evacuated tube solar water heater manifold was inclined at 1 degrees to the horizontal, reverse fluid flow was observed to occur for 69% of the monitored diurnal periods. Diurnal reverse circulation lowers system efficiency by reducing thermal stratification in the hot water storage tank via convective entrainment and mixing. The thermal performance of the ETSWH was monitored continuously from January 2007 to June 2007 with the manifold inclined at 5 degrees to the horizontal. Over this time period it was found that fluid flow reversal arose for 22% of the diurnal periods considered, resulting in a 47% improvement in diurnal storage efficiency compared to when the system had its manifold inclined at 1 degrees. The long term diurnal storage efficiency of the optimised system inclined at 5 degrees was measured as 66%.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 50 条
  • [1] Thermosyphon heat-pipe evacuated tube solar water heaters for northern maritime climates
    Redpath, David A. G.
    SOLAR ENERGY, 2012, 86 (02) : 705 - 715
  • [2] Experimental investigation of natural convection heat exchange within a physical model of the manifold chamber of a thermosyphon heat-pipe evacuated tube solar water heater
    Redpath, David A. G.
    Eames, Philip C.
    Lo, Steve N. G.
    Griffiths, Phillip W.
    SOLAR ENERGY, 2009, 83 (07) : 988 - 997
  • [3] EXPERIMENTAL INVESTIGATION OF ENERGY CHARACTERISTICS OF EVACUATED TUBE HEAT-PIPE SOLAR COLLECTOR SYSTEM
    Kavolynas, Antanas
    Drejeris, Rolandas
    7TH INTERNATIONAL SCIENTIFIC CONFERENCE RURAL DEVELOPMENT 2015: TOWARDS THE TRANSFER OF KNOWLEDGE, INNOVATIONS AND SOCIAL PROGRESS, 2015,
  • [4] Theoretical and experimental analysis of the thermal performance of a heat-pipe evacuated solar tube
    He, ZN
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 849 - 854
  • [5] THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THE EVACUATED TUBE SOLAR WATER HEATER SYSTEM
    Sakulchangsatjatai, Phrut
    Wannagosit, Chaiwat
    Kammuang-Lue, Niti
    Terdtoon, Pradit
    THERMAL SCIENCE, 2020, 24 (02): : 795 - 808
  • [6] Experimental and theoretical investigation of an evacuated tube solar water heater incorporating wickless heat pipes
    Al-Joboory, Hassan Naji Salman
    ARCHIVES OF THERMODYNAMICS, 2020, 41 (03) : 3 - 31
  • [7] Experimental and theoretical investigation of an evacuated tube solar water heater incorporating wickless heat pipes
    AL-JOBOORY, HASSAN NAJI SALMAN
    Archives of Thermodynamics, 2020, 41 (03): : 3 - 31
  • [8] A study on incorporation of thermoelectric modules with evacuated-tube heat-pipe solar collectors
    He, Wei
    Su, Yuehong
    Wang, Y. Q.
    Riffat, S. B.
    Ji, Jie
    RENEWABLE ENERGY, 2012, 37 (01) : 142 - 149
  • [9] Experimental study of a solar water desalination system utilizing evacuated tube heat pipe collector
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE TWENTY-THIRD CONFERENCE ON THE DOMESTIC USE OF ENERGY, 2015, : 155 - 162
  • [10] An experimental study of a heat pipe evacuated tube solar dryer with heat recovery system
    Daghigh, Roonak
    Shafieian, Abdellah
    RENEWABLE ENERGY, 2016, 96 : 872 - 880