Experimental investigation and optimisation study of a direct thermosyphon heat-pipe evacuated tube solar water heater subjected to a northern maritime climate

被引:9
|
作者
Redpath, D. A. G. [1 ]
Lo, S. N. G. [2 ]
Eames, P. C. [3 ]
机构
[1] Univ Ulster, Ctr Sustainable Technol, Jordanstown BT37 OQB, Antrim, North Ireland
[2] Univ Bath, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England
[3] Univ Loughborough, Ctr Renewable Energy Syst Technol, Dept Elect & Elect Engn, Loughborough LE11 3TU, Leics, England
关键词
D O I
10.1080/01430750.2010.9675106
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A proprietary heat-pipe Evacuated Tube Solar Water Heater (ETSWH) originally designed for collection of solar energy using forced fluid circulation was operated using thermosyphon fluid circulation. The thermal performance of this solar water heating system was monitored from October 2006 to June 2007. The ETSWH array was inclined with the expected collector outlet at a higher datum level than the expected collector inlet to provide a hydrostatic pressure differential across the manifold. During the monitoring period it was observed that thermosyphon flow was not always in the expected direction, with flow reversal occurring when the collector inlet temperature was greater than that of the outlet. When the evacuated tube solar water heater manifold was inclined at 1 degrees to the horizontal, reverse fluid flow was observed to occur for 69% of the monitored diurnal periods. Diurnal reverse circulation lowers system efficiency by reducing thermal stratification in the hot water storage tank via convective entrainment and mixing. The thermal performance of the ETSWH was monitored continuously from January 2007 to June 2007 with the manifold inclined at 5 degrees to the horizontal. Over this time period it was found that fluid flow reversal arose for 22% of the diurnal periods considered, resulting in a 47% improvement in diurnal storage efficiency compared to when the system had its manifold inclined at 1 degrees. The long term diurnal storage efficiency of the optimised system inclined at 5 degrees was measured as 66%.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 50 条
  • [41] Dynamic model and experimental validation of an indirect thermosyphon solar water heater coupled with a parallel circular tube rings type heat exchange coil
    Tse, Ka-Kui
    Chow, Tin-Tai
    SOLAR ENERGY, 2015, 114 : 114 - 133
  • [42] Experimental investigation of convective heat transfer performance of TiN nanofluid charged U-pipe evacuated tube solar thermal collector
    Deshmukh, Kishor
    Karmare, Suhas
    Patil, Pradeep
    APPLIED THERMAL ENGINEERING, 2023, 225
  • [43] Technical and economic performance study on winter heating system of air source heat pump assisted solar evacuated tube water heater
    Li, Jinping
    Wei, Shifan
    Dong, Yuhui
    Liu, Xiaomin
    Novakovic, Vojislav
    APPLIED THERMAL ENGINEERING, 2023, 221
  • [44] Experimental analysis of heat pipe based evacuated tube solar collector using graphene/ ethylene glycol-water nanofluids.
    Kumar, Jasvinder
    Kaushal, Rajneesh
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2020,
  • [45] Experimental investigation on the thermal appraisal of heat pipe-evacuated tube collector-based water heating system integrated with PCM
    Bouadila, Salwa
    Baddadi, Sara
    Rehman, Tauseef-ur
    Ayed, Rabeb
    RENEWABLE ENERGY, 2022, 199 : 382 - 394
  • [46] Experimental study of the performance of a circular tube solar collector with closed-loop oscillating heat-pipe with check valve (CLOHP/CV)
    Rittidech, S.
    Donmaung, A.
    Kumsombut, K.
    RENEWABLE ENERGY, 2009, 34 (10) : 2234 - 2238
  • [47] Experimental study of the solar water heater integrated with shell and fi nned tube latent heat storage system
    Shalaby, S. M.
    Kabeel, A. E.
    Moharram, B. M.
    Fleafl, A. H.
    JOURNAL OF ENERGY STORAGE, 2020, 31
  • [48] Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions
    Maraj, Altin
    Londo, Andonaq
    Gebremedhin, Alemayehu
    Firat, Coskun
    RENEWABLE ENERGY, 2019, 140 : 874 - 883
  • [49] Experimental study of the thermal performance for the novel flat plate solar water heater with micro heat pipe array absorber
    Deng, Yuechao
    Zhao, Yaohua
    Quan, Zhenhua
    Zhu, Tingting
    INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 : 41 - 48
  • [50] Experimental study on a prototype of heat pipe solar water heater using refrigerant R134a as a transfer fluid
    Sitepu, T.
    Sembiring, J.
    Ambarita, H.
    TALENTA - CONFERENCE ON ENGINEERING, SCIENCE AND TECHNOLOGY 2017 (TALENTA-CEST 2017), 2018, 309