Comparison of the Clinical Outcomes of Two Types of Toric Intraocular Lens

被引:2
|
作者
Yang, Soon Won [1 ]
Lee, Jae Hoon [1 ]
Lim, Sung A. [1 ]
Chung, So Hyang [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Ophthalmol & Visual Sci, Seoul, South Korea
来源
关键词
Astigmatism; AT TORBI; Intraocular lens; Tecnis; Toric;
D O I
10.3341/jkos.2016.57.2.200
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In this study evaluated clinical outcomes and higher-order aberrations in patients with implanted Tecnis ZCT toric intraocular lens (IOL) (Abbott Medical Optics Inc., Santa Ana, CA, USA) and the Zeiss AT TORBI toric IOL (Carl Zeiss Meditec AG, Jena, Germany) in eyes with low to moderate corneal astigmatism. Methods: We conducted a retrospective study of 32 consecutive eyes of 26 patients with a visually significant cataract and moderate corneal astigmatism (higher than 1.25 diopter [D] and lower than 4.5 D) undergoing cataract surgery with implantation of the aspheric Tecnis ZCT toric IOL (Abbott Medical Optics Inc.) and the Zeiss AT TORBI toric IOL (Carl Zeiss Meditec AG). Phacoemulsification was performed by the same experienced surgeon using 2.2 mm temporal incision. Visual, refractive and aberrometric changes were evaluated during a 3-month follow-up. Power vector analysis of Cartesian astigmatism (J0) and oblique astigmatism (J45) was performed. Results: At the 3-month follow-up, corrected distance visual acuity (CDVA) and residual astigmatism showed no statistically significant differences between groups (p = 0.203 and p = 0.364, respectively). Pre- and postoperative J0 were 0.71 +/- 0.84 and 0.05 +/- 0.39 in the Tecnis Toric group and, 0.88 +/- 1.27 and -0.02 +/- 0.16 in the AT TORBI group, respectively, which showed statistically significant differences (p = 0.029 and p = 0.032, respectively). Pre- and post-operative differences of J0 and J45 were not statistically significant (p = 0.234 and p = 0.603, respectively). No eye had IOL rotation >= 10 degrees. Ocular aberrometry values were statistically significantly differenct between the groups, except for spherical aberration, which was higher in the AT TORBI group (p = 0.0047). Conclusions: Both IOLs showed good postoperative uncorrected distance visual acuity, CDVA and refractive results in this study. Rotational stability was excellent for both IOLs until the 3-month follow-up.
引用
收藏
页码:200 / 207
页数:8
相关论文
共 50 条
  • [11] Comparison of toric intraocular lens alignment error with different toric markers
    Lipsky, Lior
    Barrett, Graham
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11): : 1597 - 1601
  • [12] Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial
    Na Yeon Jung
    Dong Hui Lim
    Sung Soon Hwang
    Joo Hyun
    Tae-Young Chung
    BMC Ophthalmology, 18
  • [13] Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial
    Jung, Na Yeon
    Lim, Dong Hui
    Hwang, Sung Soon
    Hyun, Joo
    Chung, Tae-Young
    BMC OPHTHALMOLOGY, 2018, 18
  • [14] Refractive outcomes with toric intraocular lens implants.
    Mall, Sonia
    Jolly, Jasleen Kaur
    Xue, Kanmin
    Patel, Chetan K.
    MacLaren, Robert E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [15] Prediction of refractive outcomes with toric intraocular lens implantation
    Abulafia, Adi
    Barrett, Graham D.
    Kleinmann, Guy
    Ofir, Shay
    Levy, Adi
    Marcovich, Arie L.
    Michaeli, Adi
    Koch, Douglas D.
    Wang, Li
    Assia, Ehud I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05): : 936 - 944
  • [16] Anatomical and functional outcomes of toric intraocular lens implantation
    Srujana, Dubbaka
    Joshi, Dattakiran
    Sethi, Amit
    Lanka, Sriharsha
    Bhirud, Roopali Y.
    Malik, Robin
    JOURNAL OF MARINE MEDICAL SOCIETY, 2019, 21 (02) : 158 - 164
  • [17] Comparison of 3-month visual outcomes of a spherical and a toric trifocal intraocular lens
    Poyales, Francisco
    Garzon, Nuria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02): : 135 - 145
  • [18] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    S Y Lee
    H J Kwon
    H S Ahn
    K Y Seo
    E K Kim
    T-I Kim
    Eye, 2011, 25 : 1409 - 1417
  • [19] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    Lee, S. Y.
    Kwon, H. J.
    Ahn, H. S.
    Seo, K. Y.
    Kim, E. K.
    Kim, T-I
    EYE, 2011, 25 (11) : 1409 - 1417
  • [20] Clinical outcomes of a toric continuous range of vision presbyopia-correcting intraocular lens
    Orbegozo, Javier
    Perez, Angelica
    Basterra, Inaki
    Noguera, Helena
    Gonzalez, Laura
    Lauzirika, Gorka
    Pinero, David P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (07): : 724 - 732