Clinical outcomes of a toric continuous range of vision presbyopia-correcting intraocular lens

被引:0
|
作者
Orbegozo, Javier [1 ]
Perez, Angelica [1 ]
Basterra, Inaki [1 ]
Noguera, Helena [1 ]
Gonzalez, Laura [2 ,3 ]
Lauzirika, Gorka [2 ,4 ]
Pinero, David P. [5 ]
机构
[1] Miranza COI Bilbao, Ctr Oftalmol Integral Bilbao Berri SL, C Rodriguez Arias 6 2 Dep 205, Bilbao 48008, Spain
[2] Dept Miranza Grp, Barcelona, Spain
[3] Miranza Grp, Inst Microcirugia Ocular IMO Barcelona, Barcelona, Spain
[4] Miranza Begitek, Donostia San Sebastian, Spain
[5] Univ Alicante, Dept Opt Pharmacol & Anat, Crta San Vicente Raspeig S-N, Alicante 03016, Spain
来源
关键词
PATIENT SATISFACTION; VISUAL OUTCOMES; EXCHANGE; ASTIGMATISM; IMPLANTATION; ACUITY; EYES;
D O I
10.1097/j.jcrs.0000000000001428
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth-of-focus (EDOF) pattern and a diffractive multifocal platform. Setting: Miranza COI Bilbao, Bilbao, Spain. Design: Prospective case series. Methods: 35 patients (51 to 84 years) with corneal astigmatism ranging from 0.75 to 2.19 diopters (D) undergoing bilateral cataract surgery with implantation of the Synergy Toric II IOL were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. Results: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06 +/- 0.11 logMAR, 0.13 +/- 0.12 logMAR, and 0.13 +/- 0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11 +/- 0.12 logMAR and 0.10 +/- 0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within +/- 0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 D and 0.50 D, with a mean value of 0.04 +/- 0.16 D. Mean absolute IOL rotation was 3.79 +/- 2.94 degrees. Significant improvements were found in all Rasch-calibrated scores obtained with Catquest-9SF (P < .001). Conclusions: The implantation of the toric presbyopia-correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [1] Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens
    Gabric, Nikica
    Gabric, Ivan
    Gabric, Kresimir
    Biscevic, Alma
    Pinero, David P.
    Bohac, Maja
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (04) : 256 - +
  • [2] Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens
    Epitropoulos, Alice T.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [3] Comparative Analysis of the Clinical Outcomes of Two Toric Presbyopia-Correcting Intraocular Lenses
    Gabric, Kresimir
    Gabric, Nikica
    Pinero, David P.
    Gabric, Ivan
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (03) : 775 - 790
  • [4] Comparative Analysis of the Clinical Outcomes of Two Toric Presbyopia-Correcting Intraocular Lenses
    Krešimir Gabrić
    Nikica Gabrić
    David P. Piñero
    Ivan Gabrić
    Ophthalmology and Therapy, 2024, 13 : 775 - 790
  • [5] Clinical outcomes of a new four-haptic hydrophobic presbyopia-correcting intraocular lens
    Whang, Woong-Joo
    Kim, Tae-im
    Tchah, Hungwon
    Koh, Kyungmin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [6] Clinical outcomes of a new four-haptic hydrophobic presbyopia-correcting intraocular lens
    Woong-Joo Whang
    Tae-im Kim
    Hungwon Tchah
    Kyungmin Koh
    Scientific Reports, 13
  • [7] Safety and effectiveness of a new toric presbyopia-correcting posterior chamber silicone intraocular lens
    Pepose, Jay S.
    Hayashida, Jon
    Hovanesian, John
    Davies, James
    Labor, Phillips Kirk
    Whitman, Jeffrey
    Carter, Harvey
    Colvard, Michael
    Buckhurst, Phillip J.
    Khodai, Omid
    Mittleman, David
    Feinerman, Gregg
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02): : 295 - 305
  • [8] Clinical Outcomes After Bilateral Implantation of a Trifocal Presbyopia-Correcting Intraocular Lens in an Indian Population
    Ramamurthy, Dandapani
    Vasavada, Abhay
    Padmanabhan, Prema
    Reddy, Jagadesh C.
    Shetty, Naren
    Dey, Arindam
    Sudhir, Rachapalle Reddi
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 213 - 225
  • [9] Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
    Iradier, Maria T.
    Cruz, Veronica
    Gentile, Naty
    Cedano, Priscila
    Pinero, David P.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 1215 - 1221
  • [10] Presbyopia-correcting intraocular lenses
    Buznego, Carlos
    Trattler, William B.
    CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (01) : 13 - 18