Clinical outcomes of a toric continuous range of vision presbyopia-correcting intraocular lens

被引:0
|
作者
Orbegozo, Javier [1 ]
Perez, Angelica [1 ]
Basterra, Inaki [1 ]
Noguera, Helena [1 ]
Gonzalez, Laura [2 ,3 ]
Lauzirika, Gorka [2 ,4 ]
Pinero, David P. [5 ]
机构
[1] Miranza COI Bilbao, Ctr Oftalmol Integral Bilbao Berri SL, C Rodriguez Arias 6 2 Dep 205, Bilbao 48008, Spain
[2] Dept Miranza Grp, Barcelona, Spain
[3] Miranza Grp, Inst Microcirugia Ocular IMO Barcelona, Barcelona, Spain
[4] Miranza Begitek, Donostia San Sebastian, Spain
[5] Univ Alicante, Dept Opt Pharmacol & Anat, Crta San Vicente Raspeig S-N, Alicante 03016, Spain
来源
关键词
PATIENT SATISFACTION; VISUAL OUTCOMES; EXCHANGE; ASTIGMATISM; IMPLANTATION; ACUITY; EYES;
D O I
10.1097/j.jcrs.0000000000001428
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth-of-focus (EDOF) pattern and a diffractive multifocal platform. Setting: Miranza COI Bilbao, Bilbao, Spain. Design: Prospective case series. Methods: 35 patients (51 to 84 years) with corneal astigmatism ranging from 0.75 to 2.19 diopters (D) undergoing bilateral cataract surgery with implantation of the Synergy Toric II IOL were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. Results: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06 +/- 0.11 logMAR, 0.13 +/- 0.12 logMAR, and 0.13 +/- 0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11 +/- 0.12 logMAR and 0.10 +/- 0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within +/- 0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 D and 0.50 D, with a mean value of 0.04 +/- 0.16 D. Mean absolute IOL rotation was 3.79 +/- 2.94 degrees. Significant improvements were found in all Rasch-calibrated scores obtained with Catquest-9SF (P < .001). Conclusions: The implantation of the toric presbyopia-correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [31] Comparison of a Presbyopia-Correcting Supplementary Intraocular Lens Combination and a Capsular-Bag Lens: An In Vitro Study
    Khoramnia, Ramin
    Baur, Isabella Diana
    Yan, Weijia
    Labuz, Grzegorz
    Auffarth, Gerd Uwe
    DIAGNOSTICS, 2023, 13 (08)
  • [32] Comparison of rotational stability and repositioning rates of 2 presbyopia-correcting and 2 monofocal toric intraocular lenses
    Lee, Bryan S.
    Onishi, Alex C.
    Chang, David F.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 622 - 626
  • [33] Presbyopia-correcting performance and subjective outcomes of a trifocal intraocular lens in eyes with different axial lengths: A prospective cohort study
    Sun, Tong
    Liu, Yiyun
    Zhao, Xiaorui
    Gao, Yufei
    Yang, Tingting
    Lan, Qianqian
    Tang, Chuhao
    Qi, Hong
    FRONTIERS IN MEDICINE, 2022, 9
  • [34] Refraction after Implantation of Multifocal and Presbyopia-Correcting Intraocular Lenses
    Kretz, F. T. A.
    Linz, K.
    Mueller, M.
    Gerl, M.
    Koss, M. J.
    Gerl, R. H.
    Auffarth, G. U.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (08) : 953 - 956
  • [35] Vehicle Headlight Halo Simulation of Presbyopia-Correcting Intraocular Lenses
    Kohnen, Thomas
    Nouri, Sahar A.
    Carson, Daniel
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (12):
  • [36] Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision
    Monaco, Gaspare
    Gari, Mariangela
    Di Censo, Fabio
    Poscia, Andrea
    Ruggi, Giada
    Scialdone, Antonio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06): : 737 - 747
  • [37] Maximizing Satisfaction with Presbyopia-Correcting Intraocular Lenses: The Missing Links
    Pepose, Jay S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (05) : 641 - 648
  • [38] Iris defect management in the context of presbyopia-correcting intraocular lenses
    Fram, Nicole R.
    Safran, Steven G.
    Pratte, Eli
    Sheybani, Arsham
    Agarwal, Ashvin
    Houser, Kourtney
    Garg, Sumit
    Schoen, Marisa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (08): : 889 - 894
  • [39] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Shin, Da Eun
    Lee, Hun
    Koh, Kyungmin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [40] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Da Eun Shin
    Hun Lee
    Kyungmin Koh
    BMC Ophthalmology, 22