RETRIEVAL OF OCCLUDING UNEXPANDED PALMAZ-SCHATZ STENT FROM A SAPHENOUS AORTOCORONARY VEIN GRAFT

被引:42
|
作者
ROZENMAN, Y
BURSTEIN, M
HASIN, Y
GOTSMAN, MS
机构
[1] Department of Cardiology, Hadassah University Hospital, Jerusalem
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1995年 / 34卷 / 02期
关键词
PALMAZ-SCHATZ STENT; SAPHENOUS VEIN GRAFT; UNSUCCESSFUL DEPLOYMENT;
D O I
10.1002/ccd.1810340418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Palmaz-Schatz coronary stent is used frequently to reduce the rate of restenosis of balloon angioplasty in saphenous vein grafts. In many European centers, the stent, manually crimped on a balloon, is advanced across the stenosis without a protective sheath. This report describes a patient in whom an attempt to deploy a stent in the orifice of a saphenous vein graft was complicated by dislodgement of the unexpanded stent from the balloon. The unexpanded stent caused immediate occlusion of the vein graft and severe ischemic symptoms. The stent was retrieved by inflation of another balloon in the graft, distal to the stent, pulling the balloon toward the guiding catheter, and then withdrawing the whole system. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:159 / 161
页数:3
相关论文
共 50 条
  • [41] Immediate results and dilatation effect of the vein-covered Palmaz-Schatz stent assessed by intravascular ultrasound
    Muramatsu, T
    Tukahara, R
    Hou, MM
    Ito, S
    Inoue, T
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 44 (03): : 276 - 282
  • [42] Transluminal extraction atherectomy for restenosis following Palmaz-Schatz stent implantation
    Hara, K
    Ikari, Y
    Tamura, T
    Yamaguchi, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (06): : 801 - +
  • [43] Clinical outcome of diabetic patients after Palmaz-Schatz stent implantation
    Blankenbaker, R
    Ghazzal, Z
    Weintraub, WS
    Shen, Y
    King, SB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 415A - 415A
  • [44] TECHNIQUES FOR PALMAZ-SCHATZ STENT DEPLOYMENT IN LESIONS WITH A LARGE SIDE BRANCH
    NAKAMURA, S
    HALL, P
    MAIELLO, L
    COLOMBO, A
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 34 (04): : 353 - 361
  • [45] Severe deformity of a Palmaz-Schatz stent after normal surgical manipulation
    Tovar, EA
    Blau, N
    Borsari, A
    Landa, DW
    Packer, JM
    ANNALS OF THORACIC SURGERY, 1997, 63 (01): : 220 - 221
  • [46] PREDICTORS OF THROMBOTIC OCCLUSION FOLLOWING CORONARY PALMAZ-SCHATZ STENT IMPLANTATION
    DOUCET, S
    FAJADET, J
    CAILLARD, J
    CASSAGNEAU, B
    ROBERT, G
    MARCO, J
    CIRCULATION, 1992, 86 (04) : 113 - 113
  • [47] Technical considerations in deploying the sheathed Palmaz-Schatz stent in distal coronary artery and bypass graft lesions
    Agarwal, R
    Kaul, U
    Jain, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 37 (01): : 73 - 75
  • [48] IS THE PALMAZ BILIARY STENT THE PERCUTANEOUS INTERVENTION OF CHOICE FOR DISEASED AORTOCORONARY SAPHENOUS-VEIN GRAFTS
    BERNARDI, MM
    MACISAAC, AI
    ELLIS, SG
    FRANCO, I
    WHITLOW, PL
    CIRCULATION, 1993, 88 (04) : 661 - 661
  • [49] IMPLANTATION OF HALF PALMAZ-SCHATZ STENTS IN SHORT AORTO-OSTIAL LESIONS OF SAPHENOUS-VEIN GRAFTS
    NORDREHAUG, JE
    PRIESTLEY, K
    CHRONOS, N
    BULLER, N
    SIGWART, U
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (02): : 141 - 143
  • [50] Percutaneous revascularization of an extensively diseased saphenous vein bypass graft with a saphenous vein-covered palmaz stent
    Gurbel, PA
    Criado, FJ
    Curnutte, EA
    Patten, P
    SecadaLovio, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 40 (01): : 75 - 78