A NON-NEWTONIAN FLUID MODEL FOR BLOOD-FLOW THROUGH ARTERIES UNDER STENOTIC CONDITIONS

被引:99
|
作者
MISRA, JC
PATRA, MK
MISRA, SC
机构
[1] Department of Mathematics, Indian Institute of Technology, Kharagpur
关键词
D O I
10.1016/S0021-9290(05)80011-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents an analytical study on the behaviour of blood flow through an arterial segment having a mild stenosis. The artery has been treated as a thin-walled initially stressed orthotropic non-linear viscoelastic cylindrical tube filled with a non-Newtonian fluid representing blood. The analysis is restricted to propagation of small-amplitude harmonic waves, generated due to blood flow whose wave length is large compared to the radius of the arterial segment. For the equations of motion of the arterial wall consideration is made of a pair of appropriate equations derived by using suitable constitutive relations and the principle of superimposition of a small additional deformation on a state of known finite deformation. It has been shown through numerical computations of the resulting analytical expressions that the resistance to flow and the wall shear increase as the size of the stenosis increases. A quantitative analysis is also made for the frequency variation of the flow rate at different locations of the artery, as well as of the phase velocities and transmission per wavelength.
引用
收藏
页码:1129 / 1141
页数:13
相关论文
共 50 条
  • [31] sAn unsteady analysis of non-Newtonian blood flow through tapered arteries with a stenosis
    Mandal, PK
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2005, 40 (01) : 151 - 164
  • [32] Pulsatile non-Newtonian blood flow through a model of arterial stenosis
    Rabby, Mir Golam
    Razzak, Abdur
    Molla, Md. Mamun
    5TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2013, 56 : 225 - 231
  • [33] Slip effects on unsteady non-Newtonian blood flow through an inclined catheterized overlapping stenotic artery
    Zaman, Akbar
    Ali, Nasir
    Sajid, M.
    AIP ADVANCES, 2016, 6 (01):
  • [34] Biomedical study of effects nanoparticles on unsteady blood (non-Newtonian) flow through a catheterized stenotic vessel
    Zaman, Akbar
    Sajid, M.
    Kousar, Nabeela
    CANADIAN JOURNAL OF PHYSICS, 2019, 97 (05) : 487 - 497
  • [35] FLOW OF NON-NEWTONIAN FLUID THROUGH CIRCULAR TUBES
    GHOSHAL, A
    PURE AND APPLIED GEOPHYSICS, 1970, 83 (06) : 82 - &
  • [36] Flow of a non-Newtonian fluid
    V. G. Pridanov
    V. I. Khonichev
    Technical Physics, 2012, 57 : 1475 - 1478
  • [37] FLOW OF NON-NEWTONIAN FLUID
    THIRIET, M
    MARTINBORRET, G
    HECHT, F
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1995, 103 (03) : C151 - C151
  • [38] ANGIOSCOPY OF BLOOD-FLOW THROUGH STENOTIC ARTERIES - RHEOLOGIC MECHANISM OF THROMBOSIS
    UCHIDA, Y
    TOMARU, T
    KATO, A
    SONOKI, H
    SUGIMOTO, T
    AMERICAN HEART JOURNAL, 1987, 114 (06) : 1504 - 1506
  • [39] Flow of Newtonian and Non-Newtonian Fluid Through Pipe with Flexible Wall
    Sedivy, Dominik
    Fialova, Simona
    Jasikova, Darina
    37TH MEETING OF DEPARTMENTS OF FLUID MECHANICS AND THERMODYNAMICS, 2018, 2000
  • [40] STEADY FLOW OF A NON-NEWTONIAN FLUID THROUGH A CONTRACTION
    GATSKI, TB
    LUMLEY, JL
    JOURNAL OF COMPUTATIONAL PHYSICS, 1978, 27 (01) : 42 - 70