A NON-NEWTONIAN FLUID MODEL FOR BLOOD-FLOW THROUGH ARTERIES UNDER STENOTIC CONDITIONS

被引:99
|
作者
MISRA, JC
PATRA, MK
MISRA, SC
机构
[1] Department of Mathematics, Indian Institute of Technology, Kharagpur
关键词
D O I
10.1016/S0021-9290(05)80011-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents an analytical study on the behaviour of blood flow through an arterial segment having a mild stenosis. The artery has been treated as a thin-walled initially stressed orthotropic non-linear viscoelastic cylindrical tube filled with a non-Newtonian fluid representing blood. The analysis is restricted to propagation of small-amplitude harmonic waves, generated due to blood flow whose wave length is large compared to the radius of the arterial segment. For the equations of motion of the arterial wall consideration is made of a pair of appropriate equations derived by using suitable constitutive relations and the principle of superimposition of a small additional deformation on a state of known finite deformation. It has been shown through numerical computations of the resulting analytical expressions that the resistance to flow and the wall shear increase as the size of the stenosis increases. A quantitative analysis is also made for the frequency variation of the flow rate at different locations of the artery, as well as of the phase velocities and transmission per wavelength.
引用
收藏
页码:1129 / 1141
页数:13
相关论文
共 50 条
  • [11] FDM analysis for MHD flow of a non-Newtonian fluid for blood flow in stenosed arteries
    D. S. Sankar
    Usik Lee
    Journal of Mechanical Science and Technology, 2011, 25 : 2573 - 2581
  • [12] A STUDY OF NON-NEWTONIAN ASPECTS OF BLOOD-FLOW THROUGH STENOSED ARTERIES AND ITS APPLICATIONS IN ARTERIAL DISEASES
    CHATURANI, P
    SAMY, RP
    BIORHEOLOGY, 1985, 22 (06) : 521 - 531
  • [13] FDM analysis for MHD flow of a non-Newtonian fluid for blood flow in stenosed arteries
    Sankar, D. S.
    Lee, Usik
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2011, 25 (10) : 2573 - 2581
  • [14] PULSATILE NON-NEWTONIAN BLOOD-FLOW SIMULATION THROUGH A BIFURCATION WITH AN ANEURYSM
    PERKTOLD, K
    PETER, R
    RESCH, M
    BIORHEOLOGY, 1989, 26 (06) : 1011 - 1030
  • [15] Effects of multiple stenoses and post-stenotic dilatation on non-Newtonian blood flow in small arteries
    B. Pincombe
    J. Mazumdar
    I. Hamilton-Craig
    Medical & Biological Engineering & Computing, 1999, 37 : 595 - 599
  • [16] Absorbing boundary conditions for a 3D non-Newtonian fluid-structure interaction model for blood flow in arteries
    Janela, Joao
    Moura, Alexandra
    Sequeira, Adelia
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2010, 48 (11) : 1332 - 1349
  • [17] Non-Newtonian fluid flow through a sudden pipe contraction under non-isothermal conditions
    Ryltseva, K. E.
    Borzenko, E., I
    Shrager, G. R.
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2020, 286 (286)
  • [18] A 3D non-Newtonian fluid-structure interaction model for blood flow in arteries
    Janela, Joao
    Moura, Alexandra
    Sequeira, Adelia
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2010, 234 (09) : 2783 - 2791
  • [19] INVESTIGATION OF BLOOD-LIKE NON-NEWTONIAN FLUID FLOW IN STENOTIC ARTERIES USING THE LATTICE BOLTZMANN METHOD IN 2D
    Skardova, Katerina
    Eichler, Pavel
    Oberhuber, Tomas
    Fucik, Radek
    ALGORITMY 2020: 21ST CONFERENCE ON SCIENTIFIC COMPUTING, 2020, : 91 - 100
  • [20] A MODEL FOR BLOOD-FLOW THROUGH A STENOTIC TUBE
    TANDON, PN
    RANA, UVS
    KAWAHARA, M
    KATIYAR, VK
    INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1993, 32 (01): : 61 - 78