Monte Carlo N Particle code - Dose distribution of clinical electron beams in inhomogeneous phantoms

被引:5
|
作者
Nedaie, H. A. [1 ]
Mosleh-Shirazi, M. A. [2 ]
Allahverdi, M. [3 ]
机构
[1] Univ Tehran Med Sci, Canc Inst, Canc Res Ctr, Dept Radiotherapy Phys, Tehran, Iran
[2] Shiraz Univ Med Sci, Namazi Hosp, Dept Radiotherapy, Radiotherapy Phys Unit, Shiraz, Iran
[3] Shahid Beheshti Univ, Dept Nucl Engn, Tehran, Iran
关键词
Dose distribution; dosimetry; electron therapy; heterogeneous phantom; Monte Carlo N Particle;
D O I
10.4103/0971-6203.106607
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electron dose distributions calculated using the currently available analytical methods can be associated with large uncertainties. The Monte Carlo method is the most accurate method for dose calculation in electron beams. Most of the clinical electron beam simulation studies have been performed using non- MCNP [Monte Carlo N Particle] codes. Given the differences between Monte Carlo codes, this work aims to evaluate the accuracy of MCNP4C-simulated electron dose distributions in a homogenous phantom and around inhomogeneities. Different types of phantoms ranging in complexity were used; namely, a homogeneous water phantom and phantoms made of polymethyl methacrylate slabs containing different-sized, low- and high-density inserts of heterogeneous materials. Electron beams with 8 and 15 MeV nominal energy generated by an Elekta Synergy linear accelerator were investigated. Measurements were performed for a 10 cm x 10 cm applicator at a source-to-surface distance of 100 cm. Individual parts of the beam-defining system were introduced into the simulation one at a time in order to show their effect on depth doses. In contrast to the first scattering foil, the secondary scattering foil, X and Y jaws and applicator provide up to 5% of the dose. A 2%/2 mm agreement between MCNP and measurements was found in the homogenous phantom, and in the presence of heterogeneities in the range of 1-3%, being generally within 2% of the measurements for both energies in a "complex" phantom. A full-component simulation is necessary in order to obtain a realistic model of the beam. The MCNP4C results agree well with the measured electron dose distributions.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
  • [31] Monte Carlo characterization of clinical electron beams in transverse magnetic fields
    Lee, MC
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10): : 2947 - 2967
  • [32] The OpenMC Monte Carlo particle transport code
    Romano, Paul K.
    Forget, Benoit
    ANNALS OF NUCLEAR ENERGY, 2013, 51 : 274 - 281
  • [33] Improved Electron Monte Carlo Dose Calculation for Low Energy Electron Beams Using EMC
    Fix, M. K.
    Frei, D.
    Volken, W.
    Neuenschwander, H.
    Born, E. J.
    Manser, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [34] Organ Dose Calculations Using ICRP Adult Voxel Phantoms and TRIPOLI-4 Monte Carlo Code
    Lee, Yi-Kang
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2020, 6 (04):
  • [35] Dose distribution for electron beam using Monte Carlo simulation with GATE
    Leste, J.
    Chauvin, M.
    Younes, T.
    Vieillevigne, L.
    Bardies, M.
    Franceries, X.
    Ferrand, R.
    Pierrat, N.
    Bartolucci, L.
    Simon, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S967 - S968
  • [36] Fluence correction factors in plastic phantoms for clinical proton beams: Monte Carlo calculations versus experiment
    Palmans, H
    Symons, J
    Denis, JM
    De Kock, E
    Jones, D
    Vynckier, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1327 - 1327
  • [37] Experimental validation of the FLUKA Monte Carlo code for dose and β+-emitter predictions of radioactive ion beams
    Augusto, R. S.
    Mohammadi, A.
    Tashima, H.
    Yoshida, E.
    Yamaya, T.
    Ferrari, A.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21):
  • [38] MONTE-CARLO MODELING OF CURRENT DISTRIBUTION IN SHAPED ELECTRON-BEAMS
    DAYAN, PS
    JONES, GAC
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1981, 19 (04): : 1094 - 1097
  • [39] Validation and Clinical Implementation of a Full Monte Carlo Code for Scanned Proton Pencil Beams
    Huang, S.
    Kang, M.
    Souris, K.
    Ainsley, C.
    Solberg, T.
    McDonough, J.
    Simone, C.
    Lin, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3180 - 3181
  • [40] A particle-in-cell Monte Carlo code for electron beam ion source simulation
    Zhao, L.
    Cluggish, B.
    Kim, J. S.
    Evstatiev, E. G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):